Three-phase integrated current transformer for CGIS inflatable switchgear, multiple accuracy grades and wide primary current range available; secondary lead specifications and stacked product height support customized production.
CGIS9817S is a three-phase integrated current transformer for 35kV inflatable switchgear, offering customizable accuracy and primary current ranges. Suitable for metering and protection in RMU applications.
| Paramètre | Spécification | Vérification |
|---|---|---|
| Type de produit | Current Transformer | [On Request] |
| Code modèle | CGIS9817S | Marquage de la plaque constructeur |
| Tension primaire | 35kV | Essai de tension nominale (IEC 61869-1/3) |
| Tension secondaire | [On Request] | Vérification du rapport à la fréquence nominale |
| Classe de précision | [On Request] | Essai de précision (IEC 61869-2 / IEEE C57.13) |
| Charge nominale | [On Request] | Essai de charge à la puissance VA nominale |
| Type d'isolement | Dry Epoxy Resin | Essais diélectriques selon la norme |
| Niveau d'isolement (BIL) | [On Request] | Tenue à fréquence industrielle et au choc de foudre |
| Normes | [On Request] | Certifié selon les normes listées |
| Fréquence | 50/60Hz | Selon IEC 61869-1 |
| Environnement | [On Request] | Selon les limites de la fiche technique |
Idéal pour
Non recommandé pour
For current transformers (CT), secondary terminals are designated 1S1/1S2 for the main winding, and 2S1/2S2 for the protection winding if present. Never open-circuit the secondary of a CT while energized – hazardous voltage may occur. Ground the secondary circuit at one point only, in accordance with IEC 61869-2 and IEEE C57.13. Ensure shorting links are provided before disconnecting the secondary wiring.
Conforme à : [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q : What is the primary voltage rating of the CGIS9817S?
R : The primary voltage is 35kV, suitable for 35kV systems.
Q : Can the CGIS9817S be used for outdoor installations?
R : No, it is designed for indoor inflatable switchgear (CGIS) and ring main units.
Q : What are the available accuracy classes?
R : Multiple accuracy grades are available, but specific classes are [On Request].
Les champs manquants sont marqués [On Request] — jamais inventés. Les lignes de vérification M2/M5/M6 suivent les conventions IEC 61869 / IEEE C57.13.
| Accuracy classCombined | Rated primary current (A) | 200 | 300 | 400 | 500 | 600 | 700 | 800 |
|---|---|---|---|---|---|---|---|---|
| 0.2/5P10 | 2.5 | 30 | 40 | 50 | 60 | 70 | 80 | — |
| 5 | 60 | 70 | 80 | 90 | 100 | 110 | — | |
| 7.5 | 85 | 100 | 115 | 130 | 145 | 160 | — | |
| 10 | 105 | 125 | 145 | 165 | 185 | 205 | — | |
| 15 | 135 | 160 | 185 | 210 | 235 | 260 | — | |
| 20 | 165 | 195 | 225 | 255 | 285 | 315 | — | |
| 25 | 195 | 230 | 265 | 300 | 335 | 370 | — | |
| 0.5/5P10 | 2.5 | 30 | 40 | 50 | 60 | 70 | 80 | — |
| 5 | 60 | 70 | 80 | 90 | 100 | 110 | — | |
| 7.5 | 85 | 100 | 115 | 130 | 145 | 160 | — | |
| 10 | 105 | 125 | 145 | 165 | 185 | 205 | — | |
| 15 | 135 | 160 | 185 | 210 | 235 | 260 | — | |
| 20 | 165 | 195 | 225 | 255 | 285 | 315 | — | |
| 25 | 195 | 230 | 265 | 300 | 335 | 370 | — | |
| 5P10/5P10 | 2.5 | 30 | 40 | 50 | 60 | 70 | 80 | — |
| 5 | 60 | 70 | 80 | 90 | 100 | 110 | — | |
| 7.5 | 85 | 100 | 115 | 130 | 145 | 160 | — | |
| 10 | 105 | 125 | 145 | 165 | 185 | 205 | — | |
| 15 | 135 | 160 | 185 | 210 | 235 | 260 | — | |
| 20 | 165 | 195 | 225 | 255 | 285 | 315 | — | |
| 25 | 195 | 230 | 265 | 300 | 335 | 370 | — | |
| 5P15/5P15 | 2.5 | 30 | 40 | 50 | 60 | 70 | 80 | — |
| 5 | 60 | 70 | 80 | 90 | 100 | 110 | — | |
| 7.5 | 85 | 100 | 115 | 130 | 145 | 160 | — | |
| 10 | 105 | 125 | 145 | 165 | 185 | 205 | — | |
| 15 | 135 | 160 | 185 | 210 | 235 | 260 | — | |
| 20 | 165 | 195 | 225 | 255 | 285 | 315 | — | |
| 25 | 195 | 230 | 265 | 300 | 335 | 370 | — | |
| 5P20/5P20 | 2.5 | 30 | 40 | 50 | 60 | 70 | 80 | — |
| 5 | 60 | 70 | 80 | 90 | 100 | 110 | — | |
| 7.5 | 85 | 100 | 115 | 130 | 145 | 160 | — | |
| 10 | 105 | 125 | 145 | 165 | 185 | 205 | — | |
| 15 | 135 | 160 | 185 | 210 | 235 | 260 | — | |
| 20 | 165 | 195 | 225 | 255 | 285 | 315 | — | |
| 25 | 195 | 230 | 265 | 300 | 335 | 370 | — |