Split-core zero sequence current transformer specially designed for 6kV-35kV indoor cable head outlets. Can be installed without power interruption - split into two halves and bolted together. Rated frequency 50Hz or 60Hz. Inner diameter range Φ100 to Φ250, suitable for various cable sizes. Compliant with IEC 61869 and GB/T 20840 standards. Hot-line installation capability saves downtime and maintenance cost. Epoxy resin cast construction, reliable performance.
Split-core zero-sequence CT for 6-35kV indoor cable head outlets, installable without power interruption.
| Paramètre | Spécification | Vérification |
|---|---|---|
| Type de produit | Current Transformer | IEC 61869, GB/T 20840 |
| Code modèle | LKZB-100-250 | Marquage de la plaque constructeur |
| Tension primaire | 6kV-35kV | Essai de tension nominale (IEC 61869-1/3) |
| Tension secondaire | [On Request] | Vérification du rapport à la fréquence nominale |
| Classe de précision | [On Request] | Essai de précision (IEC 61869-2 / IEEE C57.13) |
| Charge nominale | [On Request] | Essai de charge à la puissance VA nominale |
| Type d'isolement | Dry Epoxy Resin | Essais diélectriques selon la norme |
| Niveau d'isolement (BIL) | [On Request] | Tenue à fréquence industrielle et au choc de foudre |
| Normes | IEC 61869, GB/T 20840 | Certifié selon les normes listées |
| Fréquence | 50/60Hz | Selon IEC 61869-1 |
| Environnement | Epoxy resin cast | Selon les limites de la fiche technique |
Idéal pour
Non recommandé pour
For current transformers, never open-circuit the secondary while energized - hazardous voltage. Terminals: 1S1/1S2 for main winding, 2S1/2S2 for zero-sequence winding. Ground the secondary at one point. Follow IEC 61869 for terminal markings.
Conforme à : IEC 61869, GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q : Can this CT be installed without power interruption?
R : Yes, the split-core design allows hot-line installation.
Q : What is the inner diameter range?
R : Φ100 to Φ250, suitable for various cable sizes.
Q : What standards does it comply with?
R : IEC 61869 and GB/T 20840.
Les champs manquants sont marqués [On Request] — jamais inventés. Les lignes de vérification M2/M5/M6 suivent les conventions IEC 61869 / IEEE C57.13.
| Rated current ratio (A) | Accuracy class | Rated output (VA) |
|---|---|---|
| 50/1 | 10P10 | 1 |
| 75/1 | 10P10 | 1.5 |
| 100/1~150/1 | 10P10 | 2.5 |
| 200/1~600/1 | 10P10 | 5 |

Dessin d'encombrement et de dimensions du LKZB-100-250 — cliquez sur l'image pour zoomer / afficher l'original.