Indoor low voltage protection current transformer, 0.66kV rated, epoxy resin casting type, for protection applications in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Wide range of current ratios available, multiple protection accuracy classes 5P, 10P. Compact size, easy installation, suitable for switchgear and panel mounting. Customizable ratios and specifications.
LMK-0.66P is a low-voltage protection current transformer for indoor use, suitable for protection applications in LV distribution systems.
| Paramètre | Spécification | Vérification |
|---|---|---|
| Type de produit | Current Transformer | IEC 61869 / GB/T 20840 |
| Code modèle | LMK-0.66P | Marquage de la plaque constructeur |
| Tension primaire | 0.66kV | Essai de tension nominale (IEC 61869-1/3) |
| Tension secondaire | 5A/1A | Vérification du rapport à la fréquence nominale |
| Classe de précision | 5P/10P | Essai de précision (IEC 61869-2 / IEEE C57.13) |
| Charge nominale | [On Request] | Essai de charge à la puissance VA nominale |
| Type d'isolement | Dry Epoxy Resin | Essais diélectriques selon la norme |
| Niveau d'isolement (BIL) | [On Request] | Tenue à fréquence industrielle et au choc de foudre |
| Normes | IEC 61869 / GB/T 20840 | Certifié selon les normes listées |
| Fréquence | 50/60Hz | Selon IEC 61869-1 |
| Environnement | [On Request] | Selon les limites de la fiche technique |
Idéal pour
Non recommandé pour
Connect primary winding in series with the line. Secondary terminals are 1S1 and 1S2 for the main protection winding. If a second winding exists, use 2S1-2S2. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point only. Follow IEC 61869 / GB/T 20840 for installation.
Conforme à : IEC 61869 / GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q : What is the insulation type?
R : Dry epoxy resin.
Q : What accuracy classes are available?
R : 5P and 10P.
Q : Is it suitable for outdoor use?
R : No, it is designed for indoor use only.
Les champs manquants sont marqués [On Request] — jamais inventés. Les lignes de vérification M2/M5/M6 suivent les conventions IEC 61869 / IEEE C57.13.
| Model | Overall dimensions | Window dimensions (mm) a×e | ||
|---|---|---|---|---|
| W | D | H | ||
| LMK(1,2,3)-0.66/60P | 129 | 75 | 200 | 63×54 |
| LMK(1,2,3)-0.66/80P | 164 | 75 | 185 | 83×55 |
| LMK(1,2,3)-0.66/100P | 190 | 75 | 185 | 104×57 |
| LMK(1,2,3)-0.66/120P | 220 | 91 | 217 | 129×81 |
| LMK(1,2,3)-0.66/170P | 255 | 60 | 215 | 167×106 |
| LMK(1,2,3)-0.66/220P | 279 | 60 | 184 | 225×57 |

Dessin d'encombrement et de dimensions du LMK-0.66P — cliquez sur l'image pour zoomer / afficher l'original.