Indoor low voltage current transformer, 0.5kV rated, epoxy resin casting type, for current measurement and protection in low voltage distribution systems. Complies with IEC 60044-1 and GB/T 1208 standards. Wide range of current ratios available, multiple accuracy classes 0.2, 0.5, 1.0. Compact size, easy installation, suitable for switchgear and panel mounting. Customizable ratios and specifications.
LMZJ1-0.5 is a low-voltage current transformer for indoor use, suitable for measurement and protection in LV distribution systems. It offers multiple accuracy classes and customizable ratios.
| Paramètre | Spécification | Vérification |
|---|---|---|
| Type de produit | Current Transformer | IEC 60044-1 / GB/T 1208 |
| Code modèle | LMZJ1-0.5 | Marquage de la plaque constructeur |
| Tension primaire | 0.5kV | Essai de tension nominale (IEC 61869-1/3) |
| Tension secondaire | 5A/1A | Vérification du rapport à la fréquence nominale |
| Classe de précision | 0.2/0.5/1.0 | Essai de précision (IEC 61869-2 / IEEE C57.13) |
| Charge nominale | [On Request] | Essai de charge à la puissance VA nominale |
| Type d'isolement | Dry Epoxy Resin | Essais diélectriques selon la norme |
| Niveau d'isolement (BIL) | [On Request] | Tenue à fréquence industrielle et au choc de foudre |
| Normes | IEC 60044-1 / GB/T 1208 | Certifié selon les normes listées |
| Fréquence | 50/60Hz | Selon IEC 61869-1 |
| Environnement | [On Request] | Selon les limites de la fiche technique |
Idéal pour
Non recommandé pour
For CT secondary wiring, ensure terminals 1S1 and 1S2 are used for the main secondary winding. If a protection winding is present, use 2S1 and 2S2. Never open-circuit the secondary of a CT while energized - hazardous voltage may occur. Ground the secondary circuit at one point only. Follow IEC 61869-2 for terminal markings and safety requirements.
Conforme à : IEC 60044-1 / GB/T 1208
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q : What is the rated primary voltage of the LMZJ1-0.5?
R : The rated primary voltage is 0.5kV, suitable for low-voltage systems.
Q : What accuracy classes are available?
R : Accuracy classes 0.2, 0.5, and 1.0 are available for different measurement and protection needs.
Q : Can the current ratio be customized?
R : Yes, the current ratio can be customized to meet specific application requirements.
Les champs manquants sont marqués [On Request] — jamais inventés. Les lignes de vérification M2/M5/M6 suivent les conventions IEC 61869 / IEEE C57.13.
| Model | Rated primary current (A) | Rated output (VA) 0.2 class | Rated output (VA) 0.5 class | Rated output (VA) 1 class | Primary Turns through core |
|---|---|---|---|---|---|
| LMZ1-0.5 | 5 | 2.5 | 5 | 5 | 30 |
| LMZ1-0.5 | 10 | 2.5 | 5 | 5 | 15 |
| LMZ1-0.5 | 15 | 2.5 | 5 | 5 | 10 |
| LMZ1-0.5 | 20 | 2.5 | 5 | 5 | 8 |
| LMZ1-0.5 | 30 | 2.5 | 5 | 5 | 5 |
| LMZ1-0.5 | 50 | 2.5 | 5 | 5 | 3 |
| LMZ1-0.5 | 75 | 2.5 | 5 | 5 | 2 |
| LMZ1-0.5 | 100 | 2.5 | 5 | 5 | 2 |
| LMZ1-0.5 | 100 | - | - | 5 | 1 |
| LMZ1-0.5 | 150-250 | - | - | 5 | 1 |
| LMZ1-0.5 | 300 | 5 | 5 | 7.5 | 1 |
| LMZ1-0.5 | 400 | 5 | 5 | 7.5 | 1 |
| LMZ(J)1-0.5 | 500-600 | 10 | 10 | 15 | 1 |
| LMZ(J)1-0.5 | 1000-1500 | 20 | 20 | 30 | 1 |
| LMZ(J)1-0.5 | 2000-3000 | 20 | 20 | 30 | 1 |

Dessin d'encombrement et de dimensions du LMZJ1-0.5 — cliquez sur l'image pour zoomer / afficher l'original.