Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, rated insulation level 12/42/75kV, 50/60Hz, secondary current 5A/1A. Optional primary current ranges:20-150A、200A、300A、400A、500A、600-800A; accuracy combinations of 0.2S/0.2S、0.2S/0.5S、0.2S/510P10 with rated output 15VA for each accuracy class. Matched thermal and dynamic withstand parameters for different specifications, net weight 15kg, operating temperature -5℃~+40℃.
LZZB1-10 is a 10kV indoor epoxy cast current transformer for metering and protection, suitable for medium voltage switchgear panels.
| Paramètre | Spécification | Vérification |
|---|---|---|
| Type de produit | Current Transformer | IEC 61869 / GB/T 20840 |
| Code modèle | LZZB1-10 | Marquage de la plaque constructeur |
| Tension primaire | 0.66kV | Essai de tension nominale (IEC 61869-1/3) |
| Tension secondaire | 5A/1A | Vérification du rapport à la fréquence nominale |
| Classe de précision | 0.2/0.5/1.0 | Essai de précision (IEC 61869-2 / IEEE C57.13) |
| Charge nominale | [On Request] | Essai de charge à la puissance VA nominale |
| Type d'isolement | Dry Epoxy Resin | Essais diélectriques selon la norme |
| Niveau d'isolement (BIL) | [On Request] | Tenue à fréquence industrielle et au choc de foudre |
| Normes | IEC 61869 / GB/T 20840 | Certifié selon les normes listées |
| Fréquence | 50/60Hz | Selon IEC 61869-1 |
| Environnement | [On Request] | Selon les limites de la fiche technique |
Idéal pour
Non recommandé pour
Connect primary through the bushing. Secondary terminals: 1S1/1S2 for metering, 2S1/2S2 for protection. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.
Conforme à : IEC 61869 / GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q : What is the insulation level of LZZB1-10?
R : The insulation level is 12/42/75kV, meaning 12kV highest voltage for equipment, 42kV power-frequency withstand, 75kV lightning impulse withstand.
Q : What are the available accuracy classes?
R : Accuracy classes include 0.2S/0.2S, 0.2S/0.5S, and 0.2S/5P10, with rated output 15VA per class.
Q : Can it be used for outdoor applications?
R : No, it is designed for indoor use only, as it is epoxy cast and not weatherproof.
Les champs manquants sont marqués [On Request] — jamais inventés. Les lignes de vérification M2/M5/M6 suivent les conventions IEC 61869 / IEEE C57.13.
| Rated primary current (A) | Accuracy classCombined | Accuracy class & rated output (VA) | Short-time thermal current (kA/S) | Rated dynamic current (kA) | Weight (kg) |
|---|---|---|---|---|---|
| 20 | 0.2/5(0.2/5) 0.2/5(0.5/5) 0.5/5(0.5/5) 0.5/5(10P/10) | 15 | 100 | 250 | — |
| 300 | — | 15 | 24 | 60 | — |
| 400 | — | 15 | 32 | 80 | 15 |
| 500 | — | 15 | 40 | 100 | — |
| 600-800 | — | 15 | 48 | 120 | — |

Dessin d'encombrement et de dimensions du LZZB1-10 — cliquez sur l'image pour zoomer / afficher l'original.