Single-phase epoxy resin cast power transformer for 10kV/6kV pole-mounted switchgear. Provides reliable control power supply for circuit breakers. Compliant with IEC 60076 and GB 1094 standards. Low partial discharge, excellent moisture resistance. Customizable voltage ratio and capacity.
Epoxy cast single-phase power transformer for 10kV/6kV pole-mounted switchgear control power; IEC 60076 compliant.
| Paramètre | Spécification | Vérification |
|---|---|---|
| Type de produit | Power Transformer | IEC 60076, GB 1094 |
| Code modèle | DC-1-10-6 | Marquage de la plaque constructeur |
| Tension primaire | 10kV/6kV | Essai de tension nominale (IEC 61869-1/3) |
| Tension secondaire | [On Request] | Vérification du rapport à la fréquence nominale |
| Classe de précision | [On Request] | Essai de précision (IEC 61869-2 / IEEE C57.13) |
| Charge nominale | [On Request] | Essai de charge à la puissance VA nominale |
| Type d'isolement | Dry Epoxy Resin | Essais diélectriques selon la norme |
| Niveau d'isolement (BIL) | [On Request] | Tenue à fréquence industrielle et au choc de foudre |
| Normes | IEC 60076, GB 1094 | Certifié selon les normes listées |
| Fréquence | 50/60Hz | Selon IEC 61869-1 |
| Environnement | Indoor single-phase epoxy cast epoxy resin cast | Selon les limites de la fiche technique |
Idéal pour
Non recommandé pour
For power transformers, ground the secondary winding at one point. Ensure primary and secondary connections match the required voltage ratio. Follow IEC 60076 terminal markings (e.g., 1U1-1U2 for primary, 2U1-2U2 for secondary). Never operate with secondary short-circuited unless designed for it.
Conforme à : IEC 60076, GB 1094
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q : What are the primary voltage options?
R : The primary voltage is 10kV/6kV, selectable via tap configuration.
Q : Is this transformer suitable for outdoor use?
R : It is designed for indoor or pole-mounted switchgear; outdoor use requires additional weatherproofing.
Q : What standards does it comply with?
R : It complies with IEC 60076 and GB 1094.
Les champs manquants sont marqués [On Request] — jamais inventés. Les lignes de vérification M2/M5/M6 suivent les conventions IEC 61869 / IEEE C57.13.
| Model | Rated voltage ratio (kV) | Accuracy classCombined | 220V winding rated output (VA) | 100V winding rated output (VA) | Weight (kg) |
|---|---|---|---|---|---|
| DC-1/10 | 10/0.1/0.22 6/0.1/0.22 | 0.2 0.5 | 1000 | 30 60 | 38 |
| DC-1/6 | 10/0.1/0.22 6/0.1/0.22 | 0.2 0.5 | 1000 | 30 60 | 38 |

Dessin d'encombrement et de dimensions du DC-1-10-6 — cliquez sur l'image pour zoomer / afficher l'original.