Outdoor pole-mounted R-type bushing power transformer, 20kV/15kV. 4000/5000VA capacity, special R-type bushing design. Epoxy resin cast construction. Compliant with IEC 60076 standards. Weather-resistant, easy integration with switchgear.
This is a 20kV/15kV single-phase dry-type power transformer for outdoor pole-mounted switchgear control power. It is suitable for control power applications but not for metering or protection.
| Paramètre | Spécification | Vérification |
|---|---|---|
| Type de produit | Power Transformer | IEC 60076, GB 1094 |
| Code modèle | DC4-5-20-15R | Marquage de la plaque constructeur |
| Tension primaire | 20kV/15kV | Essai de tension nominale (IEC 61869-1/3) |
| Tension secondaire | [On Request] | Vérification du rapport à la fréquence nominale |
| Classe de précision | [On Request] | Essai de précision (IEC 61869-2 / IEEE C57.13) |
| Charge nominale | [On Request] | Essai de charge à la puissance VA nominale |
| Type d'isolement | Dry Epoxy Resin | Essais diélectriques selon la norme |
| Niveau d'isolement (BIL) | [On Request] | Tenue à fréquence industrielle et au choc de foudre |
| Normes | IEC 60076, GB 1094 | Certifié selon les normes listées |
| Fréquence | 50/60Hz | Selon IEC 61869-1 |
| Environnement | Outdoor pole-mounted R-type bushing epoxy resin cast | Selon les limites de la fiche technique |
Idéal pour
Non recommandé pour
For power transformers, ensure the secondary winding is grounded at one point. Follow IEC 60076 terminal markings: primary terminals H1/H2, secondary X1/X2. Never operate with secondary open-circuited if supplying inductive loads. Verify polarity for parallel operation.
Conforme à : IEC 60076, GB 1094
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q : What is the insulation level of this transformer?
R : The spec does not provide insulation level; it is [On Request].
Q : Can this transformer be used for voltage measurement?
R : No, it is a power transformer for control power, not a voltage transformer for metering.
Q : Is the primary voltage selectable?
R : Yes, the primary can be connected for 20kV or 15kV as per the spec.
Les champs manquants sont marqués [On Request] — jamais inventés. Les lignes de vérification M2/M5/M6 suivent les conventions IEC 61869 / IEEE C57.13.
| Model | Rated voltage ratio (kV) | Accuracy classCombined | 220V winding rated output (VA) | 100V winding rated output (VA) | Weight (kg) |
|---|---|---|---|---|---|
| DC-4、5/20R | 20/0.22 15/0.22 | 0.2、0.5 | 4000、5000 | — | 110 |
| DC-4、5/15R | 20/0.1/0.22 15/0.1/0.22 | 0.2、0.5 | 4000、5000 | 30、60 | 110 |

Dessin d'encombrement et de dimensions du DC4-5-20-15R — cliquez sur l'image pour zoomer / afficher l'original.