110kV high-efficiency main power transformer with low no-load loss design, dynamic short-circuit withstand capability, and integrated optical fiber temperature monitoring.
110kV oil-immersed power transformer for utility and industrial step-down applications, rated 6.3-63 MVA with OLTC and low-loss design.
| Paramètre | Spécification | Vérification |
|---|---|---|
| Type de produit | Power Transformer | IEC 60076, IEEE C57.12, ISO 9001 |
| Code modèle | SCB13-110 | Marquage de la plaque constructeur |
| Tension primaire | 110 kV | Essai de tension nominale (IEC 61869-1/3) |
| Tension secondaire | 10.5 kV / 35 kV | Vérification du rapport à la fréquence nominale |
| Classe de précision | Metering Grade CT/PT Integrated Option | Essai de précision (IEC 61869-2 / IEEE C57.13) |
| Charge nominale | 6.3 MVA to 63 MVA | Essai de charge à la puissance VA nominale |
| Type d'isolement | Oil-Immersed | Essais diélectriques selon la norme |
| Niveau d'isolement (BIL) | 126 / 230 / 550 kV | Tenue à fréquence industrielle et au choc de foudre |
| Normes | IEC 60076, IEEE C57.12, ISO 9001 | Certifié selon les normes listées |
| Fréquence | 50/60Hz | Selon IEC 61869-1 |
| Environnement | Heavy Industrial / Substation Duty ONAN/ONAF Cooling | Selon les limites de la fiche technique |
Idéal pour
Non recommandé pour
For power transformers, ground the secondary winding at one point. Follow IEC 60076 for terminal markings: HV terminals (U, V, W) and LV terminals (u, v, w). Ensure proper polarity for parallel operation. Never operate with secondary open-circuited if CT integrated; for PT integrated, never short-circuit secondary while energized. Refer to nameplate for vector group and tap changer connections.
Conforme à : IEC 60076, IEEE C57.12, ISO 9001
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q : What is the insulation level of this transformer?
R : The insulation level is 126/230/550 kV, meaning 126kV system voltage, power-frequency withstand 230kV, lightning impulse withstand 550kV peak.
Q : What cooling methods are available?
R : ONAN/ONAF cooling is standard, suitable for heavy industrial and substation duty.
Q : Does it comply with international standards?
R : Yes, it meets IEC 60076, IEEE C57.12, and ISO 9001.
Les champs manquants sont marqués [On Request] — jamais inventés. Les lignes de vérification M2/M5/M6 suivent les conventions IEC 61869 / IEEE C57.13.

Dessin d'encombrement et de dimensions du SCB13-110 — cliquez sur l'image pour zoomer / afficher l'original.