Transformator tegangan satu fasa resin epoksi cor dalam ruangan, sesuai dengan standar GB/T20840.1, GB/T20840.3 dan IEC61869-1, IEC61869-3.
Transformator tegangan satu fasa dalam ruangan untuk sistem 10kV, terisolasi resin epoksi, cocok untuk pengukuran dan proteksi pada aplikasi RMU.
| Parameter | Spesifikasi | Verifikasi |
|---|---|---|
| Jenis Produk | Transformator Tegangan (VT) / Transformator Potensial (PT) | [Atas Permintaan] |
| Kode Model | JDZU51-10-6 | Penandaan pabrik |
| Tegangan Primer | 10kV | Uji tegangan nominal (IEC 61869-1/3) |
| Tegangan Sekunder | 0.1kV | Pemeriksaan rasio pada frekuensi nominal |
| Kelas Akurasi | 0.2,0.5 | Uji akurasi (IEC 61869-2 / IEEE C57.13) |
| Beban Nominal | 40VA / 80VA / 150VA | Uji beban pada VA nominal |
| Jenis Isolasi | Dry Epoxy Resin | Uji dielektrik sesuai standar |
| Tingkat Isolasi (BIL) | 12/42/75kV,7.2/32/60kV | Ketahanan frekuensi daya & impuls petir |
| Standar | [On Request] | Tersertifikasi sesuai standar yang tercantum |
| Frekuensi | 50Hz or 60Hz | Sesuai IEC 61869-1 |
| Lingkungan | [On Request] | Sesuai batas lembar data |
Ideal Untuk
Tidak Direkomendasikan Untuk
Untuk transformator tegangan (PT): Hubungkan primer ke saluran dan netral sesuai IEC 61869-3. Terminal sekunder adalah 1a/1n. Jangan pernah menghubung-singkat sekunder PT saat bertegangan - arus lebih berbahaya. Tanahkan belitan sekunder pada satu titik. Tingkat isolasi: sistem 12kV; tahan tegangan frekuensi daya 42kV; tahan impuls petir 75kV puncak. Juga tersedia untuk sistem 7,2kV dengan frekuensi daya 32kV dan impuls 60kV. ⚠️ Safety: Follow the nameplate terminal diagram and ground the secondary winding at one point.
Sesuai dengan: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
T: Apa tingkat isolasi PT ini?
J: Dirancang untuk sistem 12kV dengan tahan tegangan frekuensi daya 42kV dan tahan impuls petir 75kV puncak. Juga tersedia untuk sistem 7,2kV dengan 32kV dan 60kV masing-masing.
T: Apakah PT ini dapat digunakan di luar ruangan?
J: Tidak, ini dirancang hanya untuk penggunaan dalam ruangan karena konstruksi resin epoksi cornya.
T: Apa kelas akurasi yang tersedia?
J: Ini menawarkan kelas akurasi 0,2 dan 0,5, cocok untuk pengukuran dan proteksi.
Bidang yang hilang ditandai [Atas Permintaan] — tidak pernah direkayasa. Baris verifikasi M2/M5/M6 mengikuti konvensi IEC 61869 / IEEE C57.13.
| Model | Rated voltage ratio (kV) | Accuracy classCombined | Accuracy class & rated output (VA) 0.2 | Accuracy class & rated output (VA) 0.5 | Accuracy class & rated output (VA) 1.0 | Accuracy class & rated output (VA) 3P/6P | Secondary thermal limit output (VA) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|
| JDZ51-10 | 10/0.1 | 0.2 | 75 | 150 | 300 | / | 1100 | 50 |
| JDZ51-6 | 6/0.1 | 0.5 | — | — | — | — | — | — |
| JDZ51-10 | 10/0.1/0.1 | 0.2/0.5 | 30 | 50 | / | / | 2×500 | — |
| JDZF51-6 | 6/0.1/0.1 | 0.2/0.5 | — | — | — | — | — | — |
| JDZJ51-10 | 10/0.1/0.22 | 0.2 | 40 | 80 | 150 | / | Max. power supply output 600VA | — |
| JDZJ51-6 | 6/0.1/0.22 | 0.5 | — | — | — | — | — | — |
| JDZX51-10 | 10/√3/0.1/√3/0.1/3 | 0.2/6P(3P) | 60 | 150 | 300 | 100 | 800 | 45 |
| JDZX51-6 | 6/√3/0.1/√3/0.1/3 | 0.5/6P(3P) | — | — | — | — | — | — |
| JDZXF51-10 | 10/√3/0.1/√3/0.1/√3/0.1/3 | 0.2/0.5/6P(3P) | 30 | 40 | / | 100 | 2×400 | — |
| JDZXF51-6 | 6/√3/0.1/√3/0.1/√3/0.1/3 | — | — | — | — | — | — | — |

Gambar dimensi & garis besar JDZU51-10-6 — klik gambar untuk memperbesar / melihat asli.
Keluarga produk sama, rating berbeda — bandingkan sebelum menentukan spesifikasi.
Transformator Tegangan Resin Epoksi Cor Satu Fasa Luar Ruangan 35kV
Transformator tegangan resin epoksi cor satu fasa luar ruangan, nominal 35kV, untuk pengukuran tegangan dan proteksi dalam sistem distribusi daya. Sesuai dengan standar IEC 61869 dan GB/T 20840. Konstruksi resin epoksi, ketahanan cuaca baik, anti-UV, cocok untuk instalasi luar ruangan. Kelas akurasi: 0,2, 0,5, 1,0. Rasio dan spesifikasi dapat disesuaikan.
Transformator Tegangan Resin Epoksi Cor Berpelindung Logam Terisolasi Satu Fasa Dalam Ruangan
Transformator tegangan cetakan epoksi berpelindung logam dengan struktur terisolasi untuk dalam ruangan, memenuhi standar GB/T20840.1/3 & IEC61869-1/3; tingkat isolasi 40,5/95/200kV, desain selubung terhubung penuh ke tanah, berat bersih 75kg.
Transformator Tegangan Luar Ruangan Resin Epoksi Cor 35kV dengan Belitan Residual & 2 Sekring
Transformator tegangan luar ruangan satu fasa resin epoksi cor, dilengkapi belitan residual dan 2 sekring primer, nilai nominal 35kV, untuk pengukuran tegangan dan proteksi pada sistem distribusi daya. Sesuai dengan standar IEC 61869 dan GB/T 20840. Konstruksi resin epoksi, ketahanan cuaca baik, anti-UV, cocok untuk instalasi luar ruangan. Kelas akurasi: 0,2, 0,5, 3P. Rasio dan spesifikasi dapat disesuaikan.