KEMA 与 ISO 9001/14001 认证|出口 50+ 国家 (IEC 61869-3 / IEEE C57.13)
24/7 全球工程热线: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
首页产品AI 选型关于我们博客联系我们

国际认证与测试

通过 KEMA Labs(荷兰)、CESI 与 CNAS 国家高压测试机构认证

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

全球 B2B 高压互感器门户

PotentialTransformers.com 是一家国际 OEM 与 EPC 供应商,专精干式环氧树脂浇注互感器(0.5kV 至 35kV)——电压互感器(VT/PT)、电流互感器(CT)与组合互感器,服务电力公用事业、开关柜制造商与重工业。

100% 出厂局部放电试验

关注我们 & 社交渠道

FacebookLinkedInYouTubeInstagramTikTok

产品分类

  • 电压互感器
  • 电流互感器
  • 组合互感器

工程工具

  • AI 数据中心系列
  • AI 规格与选型工作室
  • CT 负担计算器
  • 7.2–12 kV 户内浇注树脂电压互感器与电流互感器:绝缘、局部放电与 0.2S 准确级
  • 0.66 kV 低压电流互感器:穿心式、开合式与 0.5 级真正保证的是什么
  • 高压法拉第实验室测试
  • 索取技术数据表

全球支持

  • 香港中西区上环干诺道中111号永安中心16楼1602室
  • 86 18852046268
  • sales@potentialtransformers.com
  • 区域中心:阿联酋迪拜 | 德国法兰克福 | 美国休斯顿

© 2026 PotentialTransformers.com. 版权所有。为全球高压电网而造。

符合 IEC 61869-3符合 IEEE C57.13KEMA 型式试验
首页产品电流互感器CGIS1910
CGIS1910 电流互感器(应用于CGIS气体绝缘开关设备)
35kVCGIS1910
绕组与原理拓扑内部接线示意图
Primary Winding:35kV
Secondary Winding: ()
Safety:Follow nameplate terminal diagram; ground secondary at one point
电流互感器 通过 IEC 61869-3 认证
型号编号:CGIS1910

CGIS1910 电流互感器(应用于CGIS气体绝缘开关设备)

室内环氧树脂浇注式电流互感器,专为CGIS气体绝缘开关设备设计,具有多种准确级、额定负载和一次电流选项。

核心工程优势

  • 用于CGIS的室内环氧树脂浇注式电流互感器
  • 外径Ø98mm
工程数据

完整电气与机械规格

型号编号: CGIS1910

电气参数

一次额定电压 (Un):35kV
额定频率:50/60Hz

绝缘与耐受额定值

绝缘系统:干式环氧树脂浇注
局部放电水平:< 5 pC at 1.2 Un

推荐部署环境

GEO · 工程决策支持

全球工程概览

9 模块选型指南
缺失数据 = [On Request]

产品决策摘要

用于35kV CGIS的室内环氧树脂电流互感器;多种准确级和负载选项。

综合规格矩阵

参数规格验证标准
产品类型电流互感器[On Request]
型号代码CGIS1910工厂铭牌标识
一次电压35kV额定电压试验 (IEC 61869-1/3)
二次电流[On Request]额定频率下的变比校验
准确级[On Request]准确度试验 (IEC 61869-2 / IEEE C57.13)
额定负荷[On Request]额定 VA 下负荷试验
绝缘类型干式环氧树脂浇注按标准进行的介电试验
绝缘水平 (BIL)[On Request]工频与雷电冲击耐受
标准[On Request]按所列标准认证
频率50/60Hz依据 IEC 61869-1
环境[On Request]按数据表限值

适用与不适用边界

理想适用于

  • 35kV气体绝缘开关设备(CGIS)室内应用
  • GIS中的电流测量和保护
  • 多种准确级的计量和继电保护
  • 50/60Hz电力系统

不建议用于

  • 室外安装
  • 电压变换(PT应用)
  • 非气体绝缘开关设备(AIS)改造
  • 高于35kV的系统

拓扑与接线

对于CT:将二次端子1S1/1S2用于计量,2S1-2S2用于保护。CT在带电时严禁二次侧开路——会产生危险电压。根据IEC 61869-2,二次绕组应单点接地。 ⚠️ Safety: Follow the nameplate terminal diagram and ground the secondary winding at one point.

标准与合规

符合标准: [On Request]

  • 型式试验报告: [On Request]
  • 校准证书: [On Request]

负荷与误差计算 (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • 若 S_total < 0.25 × S_rated:需加补偿负荷以维持准确度。
  • 若 S_total > S_rated:无法保证准确级。

产品常见问题

问: 一次电压等级是多少?

答: 35kV。

问: 绝缘类型是什么?

答: 干式环氧树脂。

问: 外径是多少?

答: Ø98mm。

缺失字段一律标记 [On Request]——绝不编造。M2/M5/M6 验证行遵循 IEC 61869 / IEEE C57.13 惯例。

SPEC · 规格参数表

技术参数 / Technical Specifications

CGIS1910
32 列 · 35 行

CGIS1910 型充气柜用电流互感器 技术参数

准确级次容量(VA)(50)(60)(75)(100)(125)(150)(200)(250)(300)(400)(500)(600)(750)(1000)(1200)
hlhlhlhlhlhlhlhlhlhlhlhlhlhlhl
0.2FS10 / 0.5FS102.5——————130100654535303030303030303030303535———————
0.2FS10 / 0.5FS105——————165100655040303030303030303030303535———————
0.2FS10 / 0.5FS1010——————165100705035303030303030303030303535———————
0.2FS10 / 0.5FS1015——————14095654540353535353535353535353535———————
0.2FS10 / 0.5FS1020——————175120805045404040404040404040404040———————
0.2FS10 / 0.5FS1025——————14595805045454545454545454545454545———————
0.2FS10 / 0.5FS1030——————170110655550505050505050505050505050———————
0.5FS102.516511575554535303030303030303030303030303030303030303030303030
0.5FS105—————115806540353030303030303030303030303030303030303030
0.5FS1010—————1301006050403530303030303030303030303030303030303030
0.5FS1015—————135806050454035303030303030303030303030303030303030
0.5FS1020—————95756550403030303030303030303030303030303030303030
0.5FS1025—————115907555504035303030303030303030303030303030303030
0.5FS1030—————1351058565554535303030303030303030303030303030303030
5P10 / 10P102.515011065705545353030303030303030303030303030303030303030303030
5P10 / 10P1052351751351058570554540353535353535353535353535353535353535353535
5P10 / 10P1010———2351851451158570605545403535353535353535353535353535353535
5P10 / 10P1015—————20516011595807060554540404040404040404040404040404040
5P10 / 10P1020—————205150120100907565554545454545454545454545454545454545
5P10 / 10P1025—————185145120105907565555555555555555555555555555555555555
5P10 / 10P1030—————2151701401251059075656565656565656565656565656565656565
5P200 / 10P202.52201801451159075605045403535353535353535353535353535353535353535
5P200 / 10P205———2351851451208060504540353535353535353535353535353535353535
5P200 / 10P2010—————200150120105958070605555555555555555555555555555555555
5P200 / 10P2015—————2101651451301059580706565656565656565656565656565656565
5P200 / 10P2020—————21518516013511510080858585858585858585858585858585858585
5P200 / 10P2025—————2251951601401209595959595959595959595959595959595959595
5P200 / 10P2030—————235205175145110115115115115115115115115115115115115115115115115115115115115
5P30 / 10P302.5——200160130105857060555045404040404040404040404040404040404040
5P30 / 10P305————21017013511095857065605560606060606060606060606060606060
5P30 / 10P3010—————23019016013511510590808080808080808080808080808080808080
5P30 / 10P3015————————225190160140120100100100100100100100100100100100100100100100100100
5P30 / 10P3020————————————205175135125125125125125125125125125125125125125125125
5P30 / 10P3025————————————215190150150150150150150150150150150150150150150150150
5P30 / 10P3030————————————225175175175175175175175175175175175175175175175175175
工程图纸

规格与外形图纸

CGIS1910 的外形与尺寸图纸 —— 点击图片放大 / 查看原图。

产品概述

关于本产品

CGIS1910

CGIS1910 是一款 35kV 户内环氧树脂浇注电流互感器,专为 CGIS 气体绝缘开关柜设计,将一次电流转换为计量或保护用二次信号。可选准确级包括 0.2FS10、0.5SFS10、0.5FS10、5P10、10P10、5P200 和 10P20,其中 0.2FS10/0.5FS10 系列的额定输出为 2.5VA 至 30VA。计量绕组与保护绕组的配置按订单固定;确切配置请以铭牌为准。

干式环氧树脂浇注替代了油绝缘或 SF6 绝缘,减少了维护工作量与火灾负荷。表中给出 50/60Hz 下 2.5VA 至 30VA 的额定输出;绝缘水平、短时热电流和重量可按需提供。型式试验报告和例行试验报告可按需提供。

典型应用为冶金、矿山、水泥和化工工厂中的重工业配电。二次侧应单点接地,并与开关柜柜体连接;带电时严禁二次侧开路。在谐波或非正弦负载下,请对照数据表核实降额。电流比、准确级和绕组配置均可定制;试验文件和交货计划按订单报价。

同系列其他型号

同一产品族、不同规格参数 —— 选型前可横向对比。

CGIS1911 电流互感器,适用于CGIS气体绝缘开关设备
35kV
电流互感器50/60Hz

CGIS1911

电流互感器,适用于CGIS气体绝缘开关设备

室内环氧树脂浇注式电流互感器,专为CGIS气体绝缘开关设备设计,具有多种准确级、额定负载和一次电流选项。

准确级详询厂家
绝缘类型干式环氧树脂浇注
额定负荷详询厂家
查看规格
CGIS1775 电流互感器,适用于CGIS气体绝缘开关设备
35kV
电流互感器50/60Hz

CGIS1775

电流互感器,适用于CGIS气体绝缘开关设备

室内环氧树脂浇注式电流互感器,专为CGIS气体绝缘开关设备设计,具有多种准确级、额定负载和一次电流选项。

准确级详询厂家
绝缘类型干式环氧树脂浇注
额定负荷详询厂家
查看规格
CGIS1780 I 电流互感器,应用于CGIS气体绝缘开关设备
35kV
电流互感器50/60Hz

CGIS1780-I

电流互感器,应用于CGIS气体绝缘开关设备

户内环氧树脂浇注式电流互感器,专为CGIS气体绝缘开关设备设计,具有多种准确级、额定输出和一次电流选项。

准确级详询厂家
绝缘类型干式环氧树脂浇注
额定负荷详询厂家
查看规格