Indoor low voltage current transformer, 0.66kV rated, type III, busbar fixed installation, for current measurement and metering in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Large capacity, high accuracy, suitable for three-phase vertical busbar arrangement. Easy installation, wide range of current ratios available. Customizable ratios and specifications.
ALH-0.66III is a 0.66kV indoor busbar-type current transformer for accurate metering and measurement in LV distribution. It suits panelboards and switchgear with vertical busbars.
| Paramètre | Spécification | Vérification |
|---|---|---|
| Type de produit | Current Transformer | IEC 61869 / GB/T 20840 |
| Code modèle | ALH-0.66III | Marquage de la plaque constructeur |
| Tension primaire | 0.66kV | Essai de tension nominale (IEC 61869-1/3) |
| Tension secondaire | 5A/1A | Vérification du rapport à la fréquence nominale |
| Classe de précision | 0.2/0.5 | Essai de précision (IEC 61869-2 / IEEE C57.13) |
| Charge nominale | [On Request] | Essai de charge à la puissance VA nominale |
| Type d'isolement | Dry Epoxy Resin | Essais diélectriques selon la norme |
| Niveau d'isolement (BIL) | [On Request] | Tenue à fréquence industrielle et au choc de foudre |
| Normes | IEC 61869 / GB/T 20840 | Certifié selon les normes listées |
| Fréquence | 50/60Hz | Selon IEC 61869-1 |
| Environnement | [On Request] | Selon les limites de la fiche technique |
Idéal pour
Non recommandé pour
Connect primary busbar through the window. Secondary terminals: 1S1 and 1S2 for metering (if dual ratio, 2S1-2S2 for protection). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point. Follow IEC 61869 / GB/T 20840 for wiring and safety.
Conforme à : IEC 61869 / GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q : What is the rated primary voltage?
R : 0.66kV.
Q : What are the available secondary currents?
R : 5A or 1A.
Q : What accuracy classes are available?
R : 0.2 and 0.5.
Les champs manquants sont marqués [On Request] — jamais inventés. Les lignes de vérification M2/M5/M6 suivent les conventions IEC 61869 / IEEE C57.13.
| Model | Current ratio | Accuracy class | Rated burden (VA) | Overall dimensions | Window dimensions (mm) A×E | ||
|---|---|---|---|---|---|---|---|
| W | D | H | |||||
| ALH-0.66III30 | 100-150/5 | 0.5 | 2.5 | 73 | 50 | 88 | 12×32 |
| ALH-0.66III30 | 200-250/5 | 0.5 | 5 | 73 | 50 | 88 | 12×32 |
| ALH-0.66III30 | 300/5 | 0.5 | 5 | 73 | 50 | 88 | 12×32 |
| ALH-0.66III30 | 400-600/5 | 0.5/0.2 | 2.5 | 73 | 50 | 88 | 12×32 |
| ALH-0.66III30 | 150/1 | 0.5 | 2.5 | 73 | 50 | 88 | 12×32 |
| ALH-0.66III30 | 200-300/1 | 0.5 | 5 | 73 | 50 | 88 | 12×32 |
| ALH-0.66III30 | 400-600/1 | 0.5 | 5 | 73 | 50 | 88 | 12×32 |
| ALH-0.66III50 | 400-600/5 | 0.5/0.2 | 10 | 75 | 56 | 120 | 16×52 |
| ALH-0.66III50 | 1000/5 | 0.5/0.2 | 15 | 75 | 56 | 120 | 16×52 |
| ALH-0.66III50 | 150/1 | 0.5 | 2.5 | 75 | 56 | 120 | 16×52 |
| ALH-0.66III50 | 200-400/1 | 0.5 | 5 | 75 | 56 | 120 | 16×52 |
| ALH-0.66III50 | 500-1000/1 | 0.5 | 10 | 75 | 56 | 120 | 16×52 |
| ALH-0.66III80 | 400-750/5 | 0.5/0.2 | 10 | 99.5 | 56 | 139.5 | 33×62 |
| ALH-0.66III80 | 800/5 | 0.5/0.2 | 10 | 99.5 | 56 | 139.5 | 33×62 |
| ALH-0.66III80 | 1000/5 | 0.5/0.2 | 15 | 99.5 | 56 | 139.5 | 33×62 |
| ALH-0.66III80 | 1200-1500/5 | 0.5/0.2 | 15 | 99.5 | 56 | 139.5 | 33×62 |
| ALH-0.66III80 | 2000/5 | 0.5/0.2 | 25 | 99.5 | 56 | 139.5 | 33×62 |
| ALH-0.66III80 | 250-600/1 | 0.5 | 5 | 99.5 | 56 | 139.5 | 33×62 |
| ALH-0.66III80 | 800-1000/1 | 0.5 | 10 | 99.5 | 56 | 139.5 | 33×62 |
| ALH-0.66III80 | 1200-2000/1 | 0.5/0.2 | 15 | 99.5 | 56 | 139.5 | 33×62 |
| ALH-0.66III100 | 750-800/5 | 0.5/0.2 | 10 | 99 | 56 | 163.5 | 33×83 |
| ALH-0.66III100 | 1000/5 | 0.5/0.2 | 15 | 99 | 56 | 163.5 | 33×83 |
| ALH-0.66III100 | 1200-1500/5 | 0.5/0.2 | 15 | 99 | 56 | 163.5 | 33×83 |
| ALH-0.66III100 | 2000/5 | 0.5/0.2 | 20 | 99 | 56 | 163.5 | 33×83 |
| ALH-0.66III100 | 400-1000/1 | 0.5 | 10 | 99 | 56 | 163.5 | 33×83 |
| ALH-0.66III100 | 1200-2000/1 | 0.5 | 15 | 99 | 56 | 163.5 | 33×83 |
| ALH-0.66III120 | 800/5 | 0.5/0.2 | 10 | 104 | 56 | 189 | 33×103 |
| ALH-0.66III120 | 1000/5 | 0.5/0.2 | 15 | 104 | 56 | 189 | 33×103 |
| ALH-0.66III120 | 1200-1500/5 | 0.5/0.2 | 15 | 104 | 56 | 189 | 33×103 |
| ALH-0.66III120 | 2000-5000/5 | 0.5/0.2 | 20 | 104 | 56 | 189 | 33×103 |
| ALH-0.66III120 | 500-1000/1 | 0.5 | 10 | 104 | 56 | 189 | 33×103 |
| ALH-0.66III120 | 1200-2000/1 | 0.5 | 15 | 104 | 56 | 189 | 33×103 |
| ALH-0.66III120 | 2500-5000/1 | 0.5 | 20 | 104 | 56 | 189 | 33×103 |
| ALH-0.66III200 | 600/5 | 0.5/0.2 | 10 | 124.5 | 56 | 214 | 53×123 |
| ALH-0.66III200 | 1000/5 | 0.5/0.2 | 15 | 124.5 | 56 | 214 | 53×123 |
| ALH-0.66III200 | 1200-1500/5 | 0.5/0.2 | 15 | 124.5 | 56 | 214 | 53×123 |
| ALH-0.66III200 | 2000-5000/5 | 0.5/0.2 | 20 | 124.5 | 56 | 214 | 53×123 |
| ALH-0.66III200 | 600-1000/1 | 0.5 | 10 | 124.5 | 56 | 214 | 53×123 |
| ALH-0.66III200 | 1200-5000/1 | 0.5 | 15 | 124.5 | 56 | 214 | 53×123 |
| ALH-0.66III300 | 1200-1500/5 | 0.5/0.2 | 15 | 129.5 | 54.5 | 219 | 57×132 |
| ALH-0.66III300 | 2000-5000/5 | 0.5/0.2 | 20 | 129.5 | 54.5 | 219 | 57×132 |
| ALH-0.66III300 | 1200-5000/1 | 0.5 | 15 | 129.5 | 54.5 | 219 | 57×132 |

Dessin d'encombrement et de dimensions du ALH-0.66III — cliquez sur l'image pour zoomer / afficher l'original.