Indoor low voltage current transformer, 0.66kV rated, epoxy resin casting type, for current measurement and protection in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Wide range of current ratios available, multiple accuracy classes. Compact size, easy installation, suitable for switchgear and panel mounting. Customizable ratios and specifications.
BH-0.66 is a low voltage current transformer for indoor use, suitable for current measurement and protection in LV distribution systems.
| Paramètre | Spécification | Vérification |
|---|---|---|
| Type de produit | Current Transformer | IEC 61869 / GB/T 20840 |
| Code modèle | BH-0.66 | Marquage de la plaque constructeur |
| Tension primaire | 0.66kV | Essai de tension nominale (IEC 61869-1/3) |
| Tension secondaire | 5A/1A | Vérification du rapport à la fréquence nominale |
| Classe de précision | 0.2/0.5/1.0 | Essai de précision (IEC 61869-2 / IEEE C57.13) |
| Charge nominale | [On Request] | Essai de charge à la puissance VA nominale |
| Type d'isolement | Dry Epoxy Resin | Essais diélectriques selon la norme |
| Niveau d'isolement (BIL) | [On Request] | Tenue à fréquence industrielle et au choc de foudre |
| Normes | IEC 61869 / GB/T 20840 | Certifié selon les normes listées |
| Fréquence | 50/60Hz | Selon IEC 61869-1 |
| Environnement | [On Request] | Selon les limites de la fiche technique |
Idéal pour
Non recommandé pour
Connect primary conductor through the window. Secondary terminals are 1S1 and 1S2 for the main winding; if dual ratio, use appropriate taps. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869 for terminal markings and safety.
Conforme à : IEC 61869 / GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q : What is the rated voltage of BH-0.66?
R : The rated voltage is 0.66kV.
Q : What accuracy classes are available?
R : Accuracy classes available are 0.2, 0.5, and 1.0.
Q : Can it be used outdoors?
R : No, it is designed for indoor use only.
Les champs manquants sont marqués [On Request] — jamais inventés. Les lignes de vérification M2/M5/M6 suivent les conventions IEC 61869 / IEEE C57.13.
| Model | Rated current ratio (A) | Rated output (VA) | Accuracy class | Primary turns | Turns through core | Overall dimensions | Aperture dimensions (W×H) | Mounting dimensions (W×H) | ||
|---|---|---|---|---|---|---|---|---|---|---|
| W | D | H | ||||||||
| LMK1-0.66 30/5 | 30/5 | 1 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 40/5 | 40/5 | 1 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 50/5 | 50/5 | 1.5 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 60/5 | 60/5 | 2.5 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 75/5 | 75/5 | 2.5 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 100/5 | 100/5 | 2.5 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 150/5 | 150/5 | 3.75 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 200/5 | 200/5 | 5 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 250/5 | 250/5 | 5 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 300/5 | 300/5 | 5 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 400/5 | 400/5 | 5 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK2-0.66 100/5 | 100/5 | 2.5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK2-0.66 150/5 | 150/5 | 3.75 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK2-0.66 200/5 | 200/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK2-0.66 250/5 | 250/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK2-0.66 300/5 | 300/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK2-0.66 400/5 | 400/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK2-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK2-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK2-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK2-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK3-0.66 100/5 | 100/5 | 2.5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK3-0.66 150/5 | 150/5 | 3.75 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK3-0.66 200/5 | 200/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK3-0.66 250/5 | 250/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK3-0.66 300/5 | 300/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK3-0.66 400/5 | 400/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK3-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK3-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK3-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK3-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK1-0.66 150/5 | 150/5 | 2.5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 200/5 | 200/5 | 3.75 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 250/5 | 250/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 300/5 | 300/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 400/5 | 400/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 150/5 | 150/5 | 2.5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 200/5 | 200/5 | 3.75 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 250/5 | 250/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 300/5 | 300/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 400/5 | 400/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 150/5 | 150/5 | 2.5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 200/5 | 200/5 | 3.75 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 250/5 | 250/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 300/5 | 300/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 400/5 | 400/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 300/5 | 300/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK1-0.66 400/5 | 400/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK1-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK1-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK1-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK1-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK1-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK1-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK1-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK1-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK1-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK2-0.66 300/5 | 300/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK2-0.66 400/5 | 400/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK2-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK2-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK2-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK2-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK2-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK2-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK2-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK2-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK2-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK3-0.66 300/5 | 300/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK3-0.66 400/5 | 400/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK3-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK3-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK3-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK3-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK3-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK3-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK3-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK3-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK3-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK1-0.66 400/5 | 400/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK1-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK1-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK1-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK1-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK1-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK1-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK1-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK1-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK1-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK2-0.66 400/5 | 400/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK2-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK2-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK2-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK2-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK2-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK2-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK2-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK2-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK2-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK3-0.66 400/5 | 400/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK3-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK3-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK3-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK3-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK3-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK3-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK3-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK3-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK3-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK1-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK1-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK1-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK1-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK1-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK1-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK1-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK1-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK1-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK2-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK2-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK2-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK2-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK2-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK2-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK2-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK2-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK2-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK3-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK3-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK3-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK3-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK3-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK3-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK3-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK3-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK3-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK1-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK1-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK1-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK1-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK1-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK1-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK1-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK1-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK2-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK2-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK2-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK2-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK2-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK2-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK2-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK2-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK3-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK3-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK3-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK3-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK3-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK3-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK3-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK3-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK1-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK1-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK1-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK1-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK1-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK1-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK2-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK2-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK2-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK2-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK2-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK2-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK3-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK3-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK3-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK3-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK3-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK3-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |

Dessin d'encombrement et de dimensions du BH-0.66 — cliquez sur l'image pour zoomer / afficher l'original.