Indoor low voltage current transformer, 0.66kV rated, epoxy resin casting type, for current measurement and protection in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Wide range of current ratios available, multiple accuracy classes. Compact size, easy installation, suitable for switchgear and panel mounting. Customizable ratios and specifications.
LMK-0.66 is a low-voltage current transformer for indoor use, suitable for current measurement and protection in LV distribution systems up to 0.66kV.
| Paramètre | Spécification | Vérification |
|---|---|---|
| Type de produit | Current Transformer | IEC 61869 / GB/T 20840 |
| Code modèle | LMK-0.66 | Marquage de la plaque constructeur |
| Tension primaire | 0.66kV | Essai de tension nominale (IEC 61869-1/3) |
| Tension secondaire | 5A/1A | Vérification du rapport à la fréquence nominale |
| Classe de précision | 0.2/0.5/1.0 | Essai de précision (IEC 61869-2 / IEEE C57.13) |
| Charge nominale | [On Request] | Essai de charge à la puissance VA nominale |
| Type d'isolement | Dry Epoxy Resin | Essais diélectriques selon la norme |
| Niveau d'isolement (BIL) | [On Request] | Tenue à fréquence industrielle et au choc de foudre |
| Normes | IEC 61869 / GB/T 20840 | Certifié selon les normes listées |
| Fréquence | 50/60Hz | Selon IEC 61869-1 |
| Environnement | [On Request] | Selon les limites de la fiche technique |
Idéal pour
Non recommandé pour
Connect primary winding in series with the line. Secondary terminals are 1S1 and 1S2 for the main winding; if a protection winding exists, use 2S1-2S2. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869 / GB/T 20840 for terminal markings and safety.
Conforme à : IEC 61869 / GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q : What is the rated primary voltage of the LMK-0.66?
R : The rated primary voltage is 0.66kV.
Q : What accuracy classes are available?
R : Accuracy classes 0.2, 0.5, and 1.0 are available.
Q : Can the current ratio be customized?
R : Yes, the current ratio can be customized as per requirements.
Les champs manquants sont marqués [On Request] — jamais inventés. Les lignes de vérification M2/M5/M6 suivent les conventions IEC 61869 / IEEE C57.13.
| Model | Rated current ratio (A) | Rated output (VA) | Accuracy class | Primary current / turns | Turns through core | Overall dimensions | Aperture dimensions (W×H) | Mounting dimensions (W×H) | ||
|---|---|---|---|---|---|---|---|---|---|---|
| W | D | H | ||||||||
| LMK1-0.66/30 (BH-0.66/30) | 30/5 | 1 | 0.5 | 1 | 1 | 78 | 32 | 78 | 30×30 | 82×31 |
| 40/5 | 1 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 50/5 | 1 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 60/5 | 2 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 75/5 | 2 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 100/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 150/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 200/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 250/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 300/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 400/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK1-0.66/40 (BH-0.66/40) | 100/5 | 2.5 | 0.5 | 1 | 1 | 85 | 42 | 78 | 30×30 | 82×31 |
| 150/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 200/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 250/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 300/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 400/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK1-0.66/60 (BH-0.66/60) | 300/5 | 5 | 0.5 | 1 | 1 | 90 | 52 | 80 | 30×30 | 82×31 |
| 400/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1200/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK1-0.66/80 (BH-0.66/80) | 400/5 | 5 | 0.5 | 1 | 1 | 105 | 70 | 100 | 40×40 | 82×31 |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1200/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK1-0.66/100 (BH-0.66/100) | 600/5 | 5 | 0.5 | 1 | 1 | 120 | 80 | 110 | 50×50 | 82×31 |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1200/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 3000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK2-0.66/30 (SDH-0.66/30) | 150/5 | 2.5 | 0.5 | 1 | 1 | 87 | 40 | 100 | 30×30 | 82×30 |
| 200/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 250/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 300/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 400/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK2-0.66/40 (SDH-0.66/40) | 200/5 | 2.5 | 0.5 | 1 | 1 | 90 | 45 | 110 | 30×30 | 82×30 |
| 250/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 300/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 400/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1200/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK2-0.66/60 (SDH-0.66/60) | 400/5 | 5 | 0.5 | 1 | 1 | 102 | 60 | 140 | 40×40 | 82×30 |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1200/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK2-0.66/80 (SDH-0.66/80) | 600/5 | 5 | 0.5 | 1 | 1 | 108 | 80 | 150 | 50×50 | 82×30 |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1200/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 3000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK3-0.66/30 (LN-0.66/30) | 150/5 | 2.5 | 0.5 | 1 | 1 | 118 | 40 | 120 | 30×30 | 82×30 |
| 200/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 250/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 300/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 400/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK3-0.66/40 (LN-0.66/40) | 200/5 | 2.5 | 0.5 | 1 | 1 | 140 | 60 | 120 | 40×40 | 82×30 |
| 250/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 300/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 400/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1200/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK3-0.66/60 (LN-0.66/60) | 400/5 | 5 | 0.5 | 1 | 1 | 140 | 60 | 120 | 40×40 | 82×30 |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1200/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK3-0.66/80 (LN-0.66/80) | 600/5 | 5 | 0.5 | 1 | 1 | 187 | 80 | 120 | 50×50 | 82×30 |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1200/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 3000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMK3-0.66/100 (LN-0.66/100) | 1000/5 | 5 | 0.5 | 1 | 1 | 227 | 80 | 120 | 50×50 | 82×30 |
| 1200/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 3000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMZ1-0.66/30 (BH-0.66/30) | 100/5 | 2.5 | 0.5 | 1 | 1 | 248 | 88 | 110 | 30×30 | 228×80 |
| 150/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 200/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 250/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 300/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 400/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMZ1-0.66/40 (BH-0.66/40) | 200/5 | 2.5 | 0.5 | 1 | 1 | 270 | 90 | 110 | 30×30 | 228×80 |
| 250/5 | 2.5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 300/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 400/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| LMZ1-0.66/60 (BH-0.66/60) | 300/5 | 5 | 0.5 | 1 | 1 | 300 | 100 | 110 | 30×30 | 228×80 |
| 400/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 600/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 750/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 800/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1200/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 1500/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |
| 2000/5 | 5 | 0.5 | 1 | 1 | — | — | — | — | — | |

Dessin d'encombrement et de dimensions du LMK-0.66 — cliquez sur l'image pour zoomer / afficher l'original.