Low voltage indoor epoxy resin cast current transformer, rated 0.72/3kV. Suitable for low voltage distribution systems. Rated frequency 50/60Hz, secondary current 5A or 1A. Ambient temperature range -40°C to +40°C. Compliant with IEC 61869 and GB/T 20840 standards. Epoxy resin cast construction, reliable performance, easy installation. Customizable current ratio and accuracy class.
LRZ-10 is a low-voltage indoor current transformer for metering and protection in LV distribution systems, with secondary ratings of 5A or 1A.
| Paramètre | Spécification | Vérification |
|---|---|---|
| Type de produit | Current Transformer | IEC 61869, GB/T 20840 |
| Code modèle | LRZ-10 | Marquage de la plaque constructeur |
| Tension primaire | 0.72/3kV | Essai de tension nominale (IEC 61869-1/3) |
| Tension secondaire | 5A or 1A | Vérification du rapport à la fréquence nominale |
| Classe de précision | [On Request] | Essai de précision (IEC 61869-2 / IEEE C57.13) |
| Charge nominale | [On Request] | Essai de charge à la puissance VA nominale |
| Type d'isolement | Dry Epoxy Resin | Essais diélectriques selon la norme |
| Niveau d'isolement (BIL) | [On Request] | Tenue à fréquence industrielle et au choc de foudre |
| Normes | IEC 61869, GB/T 20840 | Certifié selon les normes listées |
| Fréquence | 50/60Hz | Selon IEC 61869-1 |
| Environnement | Indoor epoxy resin cast; Ambient: -40°C ~ +40°C | Selon les limites de la fiche technique |
Idéal pour
Non recommandé pour
For current transformers: Connect primary winding in series with the line. Secondary terminals are 1S1 and 1S2 for the main winding; if a protection winding exists, use 2S1-2S2. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Ensure correct polarity for metering and protection.
Conforme à : IEC 61869, GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q : What is the primary voltage rating of LRZ-10?
R : The primary voltage rating is 0.72/3kV, suitable for low voltage systems.
Q : What secondary currents are available?
R : Secondary current options are 5A or 1A.
Q : Is LRZ-10 suitable for outdoor use?
R : No, it is designed for indoor use with epoxy resin cast insulation.
Les champs manquants sont marqués [On Request] — jamais inventés. Les lignes de vérification M2/M5/M6 suivent les conventions IEC 61869 / IEEE C57.13.
| Parameter | Value |
|---|---|
| Product performance complies with standards | GB/T20840.1, 2 and IEC61869-1, 2 standards |
| Rated voltage | 0.72/3kV |
| Rated frequency | 50Hz or 60Hz |
| Rated secondary current | 5A or 1A |
| Ambient temperature | -40℃~+40℃ |