Outdoor pole-mounted single-phase power transformer, 10kV/6kV. 8000VA capacity, epoxy resin cast construction. Provides control power supply for pole-mounted switchgear. Compliant with IEC 60076 standards. Weather-resistant design, reliable outdoor performance.
Outdoor pole-mounted single-phase power transformer, 10kV/6kV, 8000VA, epoxy resin cast, for control power supply of pole-mounted switchgear.
| Paramètre | Spécification | Vérification |
|---|---|---|
| Type de produit | Power Transformer | IEC 60076, GB 1094 |
| Code modèle | DC-8-10-6 | Marquage de la plaque constructeur |
| Tension primaire | 10kV/6kV | Essai de tension nominale (IEC 61869-1/3) |
| Tension secondaire | [On Request] | Vérification du rapport à la fréquence nominale |
| Classe de précision | [On Request] | Essai de précision (IEC 61869-2 / IEEE C57.13) |
| Charge nominale | [On Request] | Essai de charge à la puissance VA nominale |
| Type d'isolement | Dry Epoxy Resin | Essais diélectriques selon la norme |
| Niveau d'isolement (BIL) | [On Request] | Tenue à fréquence industrielle et au choc de foudre |
| Normes | IEC 60076, GB 1094 | Certifié selon les normes listées |
| Fréquence | 50/60Hz | Selon IEC 61869-1 |
| Environnement | Outdoor pole-mounted single-phase epoxy resin cast | Selon les limites de la fiche technique |
Idéal pour
Non recommandé pour
For power transformers, ground the secondary winding at one point. Follow IEC 60076 terminal markings: primary terminals H1/H2, secondary terminals X1/X2. Ensure proper fusing on both primary and secondary sides. Never operate with secondary open-circuited while primary is energized.
Conforme à : IEC 60076, GB 1094
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q : What is the primary voltage rating?
R : The primary voltage is 10kV/6kV, selectable.
Q : What standards does this transformer comply with?
R : It complies with IEC 60076 and GB 1094.
Q : Is it suitable for indoor use?
R : No, it is designed for outdoor pole-mounted applications.
Les champs manquants sont marqués [On Request] — jamais inventés. Les lignes de vérification M2/M5/M6 suivent les conventions IEC 61869 / IEEE C57.13.
| Model Type | Rated voltage ratio (kV) Rated voltage ratio | Accuracy classCombined Class combination | 220V winding rated output (VA) Rated capability of winding 220V | Weight (kg) Weight |
|---|---|---|---|---|
| DC-8/10 | 10/0.1/0.22 | 0.2 | 800 Impedance voltage drop <6% | 120 |
| DC-8/6 | 6/0.22 | 0.5 | 800 Impedance voltage drop <6% | 120 |

Dessin d'encombrement et de dimensions du DC-8-10-6 — cliquez sur l'image pour zoomer / afficher l'original.