Transformator arus dalam ruangan resin epoksi cor yang dirancang untuk switchgear berisolasi gas CGIS, dengan berbagai pilihan kelas akurasi, beban nominal, dan arus primer.
CT dalam ruangan untuk CGIS pada 35kV; cocok untuk proteksi dan pengukuran pada switchgear berisolasi gas.
| Parameter | Spesifikasi | Verifikasi |
|---|---|---|
| Jenis Produk | Transformator Arus | [Atas Permintaan] |
| Kode Model | CGIS1780-I | Penandaan pabrik |
| Tegangan Primer | 35kV | Uji tegangan nominal (IEC 61869-1/3) |
| Arus Sekunder | [On Request] | Pemeriksaan rasio pada frekuensi nominal |
| Kelas Akurasi | [On Request] | Uji akurasi (IEC 61869-2 / IEEE C57.13) |
| Beban Nominal | [On Request] | Uji beban pada VA nominal |
| Jenis Isolasi | Dry Epoxy Resin | Uji dielektrik sesuai standar |
| Tingkat Isolasi (BIL) | [On Request] | Ketahanan frekuensi daya & impuls petir |
| Standar | [On Request] | Tersertifikasi sesuai standar yang tercantum |
| Frekuensi | 50/60Hz | Sesuai IEC 61869-1 |
| Lingkungan | [On Request] | Sesuai batas lembar data |
Ideal Untuk
Tidak Direkomendasikan Untuk
Untuk CT: hubungkan terminal sekunder 1S1/1S2 untuk pengukuran/proteksi utama; jika sekunder ganda, gunakan 2S1-2S2 untuk proteksi. Jangan pernah membuka rangkaian sekunder CT saat bertegangan - tegangan berbahaya. Tanahkan belitan sekunder pada satu titik. ⚠️ Safety: Follow the nameplate terminal diagram and ground the secondary winding at one point.
Sesuai dengan: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
T: Apa tingkat isolasi CT ini?
J: Tegangan primer adalah 35kV, tetapi singkatan tingkat isolasi tidak disediakan; silakan merujuk ke spesifikasi rinci atau hubungi kami.
T: Apakah CT ini dapat digunakan di luar ruangan?
J: Tidak, ini dirancang untuk penggunaan dalam ruangan di dalam CGIS.
T: Apa saja kelas akurasi yang tersedia?
J: Tersedia berbagai kelas akurasi; nilai spesifik tidak tercantum dalam data yang diberikan.
Bidang yang hilang ditandai [Atas Permintaan] — tidak pernah direkayasa. Baris verifikasi M2/M5/M6 mengikuti konvensi IEC 61869 / IEEE C57.13.
| Accuracy class | Rated output (VA) | 40 | 50 | 60 | 75 | 100 | 125 | 150 | 200 | 250 | 300 | 400 | 500 | 600 | 750 | 1000 | 1200 | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| h | l | h | l | h | l | h | l | h | l | h | l | h | l | h | l | h | l | h | l | h | l | h | l | h | l | h | l | h | l | h | l | ||
| 0.2FS10 0.5FS10 | 2.5 | — | — | — | — | — | — | — | — | — | — | — | — | — | 65 | 55 | 40 | 35 | 30 | 30 | 30 | 30 | 30 | 30 | 35 | 35 | 35 | 35 | — | — | — | — | — |
| 0.2FS10 0.5FS10 | 5 | — | — | — | — | — | — | — | — | — | — | — | — | — | 95 | 80 | 55 | 50 | 35 | 30 | 30 | 30 | 30 | 30 | 35 | 35 | 35 | 35 | — | — | — | — | — |
| 0.2FS10 0.5FS10 | 10 | — | — | — | — | — | — | — | — | — | — | — | — | — | 120 | 80 | 60 | 45 | 35 | 35 | 30 | 30 | 35 | 35 | 35 | 35 | — | — | — | — | — | — | — |
| 0.2FS10 0.5FS10 | 15 | — | — | — | — | — | — | — | — | — | — | — | — | — | 170 | 110 | 75 | 55 | 45 | 40 | 35 | 35 | 35 | 35 | 35 | 35 | — | — | — | — | — | — | — |
| 0.2FS10 0.5FS10 | 20 | — | — | — | — | — | — | — | — | — | — | — | — | — | 145 | 90 | 65 | 55 | 45 | 40 | 35 | 35 | 40 | 40 | 35 | 35 | — | — | — | — | — | — | — |
| 0.2FS10 0.5FS10 | 25 | — | — | — | — | — | — | — | — | — | — | — | — | — | 160 | 110 | 75 | 60 | 50 | 45 | 45 | 40 | 35 | 35 | — | — | — | — | — | — | — | — | — |
| 0.2FS10 0.5FS10 | 30 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 125 | 85 | 70 | 55 | 50 | 45 | 45 | 40 | 40 | 40 | — | — | — | — | — | — | — |
| 0.5 | 2.5 | — | — | — | — | — | — | — | — | — | — | — | — | — | 55 | 45 | 40 | 35 | 30 | 30 | 25 | 25 | 25 | 25 | 25 | 25 | — | — | — | — | — | — | — |
| 0.5 | 5 | — | — | — | — | — | — | — | — | — | — | — | — | — | 80 | 65 | 50 | 40 | 30 | 30 | 25 | 25 | 25 | 25 | 25 | 25 | — | — | — | — | — | — | — |
| 0.5 | 10 | — | — | — | — | — | — | — | — | — | — | — | — | — | 125 | 95 | 75 | 55 | 40 | 35 | 30 | 25 | 25 | 25 | 25 | 25 | — | — | — | — | — | — | — |
| 0.5 | 15 | — | — | — | — | — | — | — | — | — | — | — | — | — | 125 | 95 | 70 | 55 | 45 | 40 | 35 | 30 | 25 | 25 | 25 | 25 | — | — | — | — | — | — | — |
| 0.5 | 20 | — | — | — | — | — | — | — | — | — | — | — | — | — | 120 | 85 | 65 | 55 | 50 | 40 | 30 | 35 | 30 | 25 | 25 | 25 | — | — | — | — | — | — | — |
| 0.5 | 25 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 95 | 75 | 65 | 55 | 45 | 35 | 30 | 25 | 25 | 25 | — | — | — | — | — | — | — |
| 0.5 | 30 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 85 | 70 | 65 | 50 | 40 | 35 | 30 | 25 | 25 | 25 | — | — | — | — | — | — | — |
| 5(10)P10 | 2.5 | 135 | 100 | 85 | 75 | 55 | 45 | 40 | 35 | 35 | 60 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 25 | 25 | — | — | — | — | — | — | — | — |
| 5(10)P10 | 5 | — | — | — | 135 | 120 | 85 | 70 | 55 | 50 | 45 | 40 | 40 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 30 | 30 | — | — | — | — | — | — | — | — | — |
| 5(10)P10 | 10 | — | — | — | — | — | 145 | 110 | 95 | 80 | 70 | 60 | 60 | 50 | 45 | 45 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | — | — | — | — | — | — | — |
| 5(10)P10 | 15 | — | — | — | — | — | — | — | 155 | 130 | 110 | 90 | 80 | 65 | 60 | 50 | 45 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | — | — | — | — | — | — | — |
| 5(10)P10 | 20 | — | — | — | — | — | — | — | — | — | 140 | 115 | 100 | 85 | 70 | 60 | 50 | 45 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | — | — | — | — | — | — | — |
| 5(10)P10 | 25 | — | — | — | — | — | — | — | — | — | — | — | 140 | 120 | 95 | 80 | 70 | 60 | 55 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | — | — | — | — | — |
| 5(10)P10 | 30 | — | — | — | — | — | — | — | — | — | — | — | — | — | 140 | 130 | 110 | 95 | 80 | 65 | 60 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | — | — | — |
| 5(10)P20 | 2.5 | — | — | — | 145 | 125 | 90 | 75 | 65 | 60 | 50 | 50 | 50 | 45 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 |
| 5(10)P20 | 5 | — | — | — | — | — | 145 | 115 | 95 | 90 | 75 | 65 | 55 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
| 5(10)P20 | 10 | — | — | — | — | — | — | — | 150 | 125 | 110 | 105 | 85 | 75 | 70 | 60 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 |
| 5(10)P20 | 15 | — | — | — | — | — | — | — | — | — | 150 | 140 | 115 | 100 | 90 | 75 | 70 | 65 | 65 | 65 | 65 | 65 | 65 | 65 | 65 | 65 | 65 | 65 | 65 | 65 | 65 | 65 | 65 |
| 5(10)P20 | 20 | — | — | — | — | — | — | — | — | — | — | — | 145 | 125 | 115 | 90 | 80 | 75 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 |
| 5(10)P20 | 25 | — | — | — | — | — | — | — | — | — | — | — | — | — | 150 | 135 | 105 | 95 | 85 | 85 | 85 | 85 | 85 | 85 | 85 | 85 | 85 | 85 | 85 | 85 | 85 | 85 | — |
| 5(10)P20 | 30 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 150 | 135 | 105 | 95 | 85 | 85 | 85 | 85 | 85 | 85 | 85 | 85 | 85 | 85 | 85 | 85 | — |
| 5(10)P30 | 2.5 | — | — | — | — | — | 130 | 105 | 90 | 85 | 75 | 70 | 65 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 |
| 5(10)P30 | 5 | — | — | — | — | — | — | — | 145 | 135 | 115 | 100 | 95 | 80 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 |
| 5(10)P30 | 10 | — | — | — | — | — | — | — | — | — | 170 | 155 | 125 | 115 | 110 | 90 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 |
| 5(10)P30 | 15 | — | — | — | — | — | — | — | — | — | — | — | 155 | 140 | 115 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 |
| 5(10)P30 | 20 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 140 | 125 | 115 | 115 | 115 | 115 | 115 | 115 | 115 | 115 | 115 | 115 | 115 | 115 | 115 | 115 | 115 | — |
| 5(10)P30 | 25 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 145 | 145 | 145 | 145 | 145 | 145 | 145 | 145 | 145 | 145 | 145 | 145 | 145 | 145 | — |

Gambar dimensi & garis besar CGIS1780-I — klik gambar untuk memperbesar / melihat asli.
Keluarga produk sama, rating berbeda — bandingkan sebelum menentukan spesifikasi.
Transformator Arus untuk Switchgear Berisolasi Gas CGIS
Transformator arus dalam ruangan resin epoksi cor yang dirancang untuk switchgear berisolasi gas CGIS, dengan berbagai pilihan kelas akurasi, beban nominal, dan arus primer.
Transformator Arus untuk Switchgear Inflatable
Transformator arus khusus yang dirancang untuk switchgear inflatable CGIS dengan berbagai kelas akurasi dan spesifikasi arus primer yang melimpah; panjang kabel sekunder dan tinggi produk bertumpuk mendukung produksi yang disesuaikan.
35kV Transformator Arus Tipe Tiang Luar Ruangan dengan Belitan Proteksi Resin Epoksi Cor
Transformator arus tipe tiang luar ruangan 35kV W1 resin epoksi cor. Tingkat isolasi nominal 40,5/95/185kV, 50/60Hz, arus sekunder 5A atau 1A. Kombinasi kelas akurasi ganda: 0,2S/0,5S/10P10/10P25. Sesuai dengan standar IEC 61869 dan GB/T 20840. Cetakan epoksi vakum, kekuatan mekanik tinggi, kinerja isolasi sangat baik. Arus primer nominal 50-1600A, arus tahan termal waktu singkat hingga 50kA/4s. Cocok untuk sistem tenaga 35kV, rasio dan akurasi dapat disesuaikan.