Transformator arus resin epoksi cor satu fasa dalam ruangan yang sesuai dengan standar GB/T20840.1/2 dan IEC61869-1/2; tingkat isolasi nominal 40,5/95/185kV, frekuensi nominal 50/60Hz, arus sekunder nominal 5A atau 1A. Arus primer opsional mencakup 20–3150A; keluaran nominal kelas akurasi: 10VA(0,2S/0,5S), 30VA(0,5), 30VA(5P10), 20VA(5P15), 15VA(5P20); arus tahan termal waktu singkat berkisar 4–31,5kA, arus tahan dinamis nominal berkisar 10–130kA; berat produk: 78kg; suhu operasi lingkungan -5°C hingga +40°C.
Transformator arus cetakan epoksi dalam ruangan 35kV untuk pengukuran dan proteksi switchgear MV; isolasi nominal sistem 40,5kV, tahan tegangan frekuensi daya 95kV, impuls petir 185kV puncak.
| Parameter | Spesifikasi | Verifikasi |
|---|---|---|
| Jenis Produk | Transformator Arus | [Atas Permintaan] |
| Kode Model | LZZQB8-35-G | Penandaan pabrik |
| Tegangan Primer | 35kV | Uji tegangan nominal (IEC 61869-1/3) |
| Arus Sekunder | [On Request] | Pemeriksaan rasio pada frekuensi nominal |
| Kelas Akurasi | [On Request] | Uji akurasi (IEC 61869-2 / IEEE C57.13) |
| Beban Nominal | [On Request] | Uji beban pada VA nominal |
| Jenis Isolasi | Dry Epoxy Resin | Uji dielektrik sesuai standar |
| Tingkat Isolasi (BIL) | [On Request] | Ketahanan frekuensi daya & impuls petir |
| Standar | [On Request] | Tersertifikasi sesuai standar yang tercantum |
| Frekuensi | 50/60Hz | Sesuai IEC 61869-1 |
| Lingkungan | [On Request] | Sesuai batas lembar data |
Ideal Untuk
Tidak Direkomendasikan Untuk
Untuk transformator arus: terminal sekunder 1S1/1S2 untuk pengukuran, 2S1-2S2 untuk proteksi (jika berlaku). Jangan pernah membuka rangkaian sekunder transformator arus saat bertegangan - tegangan berbahaya. Hubungkan belitan sekunder ke tanah pada satu titik. Ikuti penandaan terminal IEC 61869-2. ⚠️ Safety: Follow the nameplate terminal diagram and ground the secondary winding at one point.
Sesuai dengan: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
T: Apa tingkat isolasi transformator arus ini?
J: Tingkat isolasi nominal adalah 40,5/95/185kV, yang berarti tegangan sistem 40,5kV, tahan tegangan frekuensi daya 95kV, tahan impuls petir 185kV.
T: Apakah dapat digunakan di luar ruangan?
J: Tidak, transformator arus ini dirancang hanya untuk penggunaan dalam ruangan karena konstruksi resin epoksinya.
T: Arus sekunder apa saja yang tersedia?
J: Arus sekunder nominal adalah 5A atau 1A, sesuai spesifikasi.
Bidang yang hilang ditandai [Atas Permintaan] — tidak pernah direkayasa. Baris verifikasi M2/M5/M6 mengikuti konvensi IEC 61869 / IEEE C57.13.
| Rated primary current I1n (A) | Accuracy classCombined | Accuracy class & rated output (VA) COSΦ=0.8 (0.2/0.5S) | Accuracy class & rated output (VA) COSΦ=0.8 (0.5) | Accuracy class & rated output (VA) COSΦ=0.8 (5P10) | Accuracy class & rated output (VA) COSΦ=0.8 (5P15) | Accuracy class & rated output (VA) COSΦ=0.8 (5P20) | Short-time thermal current Ith (kA/S) (kA) | Short-time thermal current Ith (kA/S) (s) | Rated dynamic current Idyn (kA) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|---|
| 20 | 0.2(S)/0.5(S) | 10 | 30 | 30 | 20 | 15 | 4 | 1 | 10 | 78 |
| 30-40 | 0.2(S)/5P | 10 | 30 | 30 | 20 | 15 | 4 | 2 | 10 | 78 |
| 50 | 0.5(S)/5P | 10 | 30 | 30 | 20 | 15 | 12 | 1 | 30 | 78 |
| 75 | 0.5(S)/5P | 10 | 30 | 30 | 20 | 15 | 16 | 1 | 40 | 78 |
| 100-150 | 0.2(S)/0.5(S)/5P | 10 | 30 | 30 | 20 | 15 | 25 | 1 | 63 | 78 |
| 200-300 | 0.2(S)/5P/5P | 10 | 30 | 30 | 20 | 15 | 31.5 | 1 | 80 | 78 |
| 400-600 | 0.5(S)/5P/5P | 10 | 30 | 30 | 20 | 15 | 31.5 | 2 | 80 | 78 |
| 800-1600 | [On Request] | 10 | 30 | 30 | 20 | 15 | 31.5 | 4 | 130 | 78 |
| 2000-3150 | [On Request] | 10 | 30 | 30 | 20 | 15 | [On Request] | [On Request] | [On Request] | 78 |

Gambar dimensi & garis besar LZZQB8-35-G — klik gambar untuk memperbesar / melihat asli.
Keluarga produk sama, rating berbeda — bandingkan sebelum menentukan spesifikasi.
Transformator Arus Resin Epoksi Cor Satu Fasa Dalam Ruangan
Transformator arus resin epoksi cor satu fasa dalam ruangan yang sesuai dengan standar GB/T20840.1/2 dan IEC61869-1/2; tingkat isolasi nominal 40,5/95/185kV, frekuensi nominal 50/60Hz, arus sekunder nominal 5A atau 1A. Arus primer opsional mencakup 20–3150A, kelas akurasi dan rating daya sama dengan seri; arus tahan termal waktu singkat berkisar 4–31,5kA, arus tahan dinamis nominal berkisar 10–130kA; berat produk: 84kg; suhu operasi lingkungan -5°C hingga +40°C.
Transformator Arus Resin Epoksi Cor Satu Fasa Dalam Ruangan
Transformator arus resin epoksi cor satu fasa dalam ruangan yang sesuai dengan standar GB/T20840.1/2 dan IEC61869-1/2; tingkat isolasi nominal 40,5/95/185kV, frekuensi nominal 50/60Hz, arus sekunder nominal 5A atau 1A. Arus primer opsional: 20–2500A, kelas akurasi dan rating daya sama dengan seri; arus termal 4–31,5kA, arus dinamis 10–130kA; berat 70kg; suhu lingkungan -5°C hingga +40°C.
Transformator Arus Resin Epoksi Cor Satu Fasa Dalam Ruangan
Transformator arus resin epoksi cor satu fasa dalam ruangan yang sesuai dengan standar GB/T20840.1/2 dan IEC61869-1/2; tingkat isolasi nominal 40,5/95/185kV, frekuensi nominal 50/60Hz, arus sekunder nominal 5A atau 1A. Arus primer opsional mencakup 30–3150A; keluaran nominal kelas akurasi: 30VA(0,2S), 30VA(0,5S), 40/50/60VA(5P10), 25/30/40VA(5P15), 15/20/30VA(5P20); arus tahan termal waktu singkat 6–31,5kA, arus tahan dinamis nominal 15–100kA; berat produk: 87kg; suhu operasi lingkungan -5°C hingga +40°C.