中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLZZQB8-35-G
LZZQB8-35G Indoor Single-phase Epoxy Resin Casting Current Transformer
35kVLZZQB8-35-G
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 35kV
Secondary Metering (1S1 - 1S2): ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LZZQB8-35-G

LZZQB8-35G Indoor Single-phase Epoxy Resin Casting Current Transformer

Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards; rated insulation level 40.5/95/185kV, rated frequency 50/60Hz, rated secondary current 5A or 1A. Optional primary current covers 20–3150A; accuracy-class rated outputs:10VA(0.2S/0.5S),30VA(0.5),30VA(5P10),20VA(5P15),15VA(5P20); short-time thermal current ranges 4–31.5kA, rated dynamic stable current ranges 10–130kA; product weight:78kg; ambient operating temperature -5℃~+40℃.

Key Engineering Advantages

  • 35kV indoor epoxy cast current transformer
  • broad current selection
  • excellent thermal and dynamic resistance
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LZZQB8-35-G

Electrical Parameters

Primary Rated Voltage (Un):35kV
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

Indoor 35kV epoxy cast CT for MV switchgear metering and protection; rated insulation 40.5kV system, power-frequency withstand 95kV, lightning impulse 185kV peak.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeLZZQB8-35-GFactory nameplate marking
Primary Voltage35kVRated voltage test (IEC 61869-1/3)
Secondary Current[On Request]Ratio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50/60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor medium voltage switchgear panels
  • Revenue metering with 0.2S/0.5S accuracy
  • Protection schemes requiring 5P10/5P15/5P20 classes
  • Systems with primary current up to 3150A
  • Ambient temperatures -5°C to +40°C

Not Recommended For

  • Outdoor or gas-insulated installations
  • DC systems or non-sinusoidal waveforms
  • High altitude above 1000m without derating
  • Applications requiring very high accuracy class 0.1
  • Primary voltages above 40.5kV

Topology & Wiring

secondary terminals 1S1/1S2 for metering, 2S1-2S2 for protection (if applicable). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the insulation level of this CT?

A: Rated insulation level is 40.5/95/185kV, meaning 40.5kV system voltage, 95kV power-frequency withstand, 185kV lightning impulse withstand.

Q: Can it be used outdoors?

A: No, it is designed for indoor use only due to epoxy resin construction.

Q: What secondary currents are available?

A: Rated secondary current is 5A or 1A, as specified.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LZZQB8-35-G
11 cols · 9 rows

LZZB8-35G LZZBJ9-35G Current Transformer

Rated primary current I1n (A)Accuracy classCombinedAccuracy class & rated output (VA) COSΦ=0.8 (0.2/0.5S)Accuracy class & rated output (VA) COSΦ=0.8 (0.5)Accuracy class & rated output (VA) COSΦ=0.8 (5P10)Accuracy class & rated output (VA) COSΦ=0.8 (5P15)Accuracy class & rated output (VA) COSΦ=0.8 (5P20)Short-time thermal current Ith (kA/S) (kA)Short-time thermal current Ith (kA/S) (s)Rated dynamic current Idyn (kA)Weight (kg)
200.2(S)/0.5(S)1030302015411078
30-400.2(S)/5P1030302015421078
500.5(S)/5P10303020151213078
750.5(S)/5P10303020151614078
100-1500.2(S)/0.5(S)/5P10303020152516378
200-3000.2(S)/5P/5P103030201531.518078
400-6000.5(S)/5P/5P103030201531.528078
800-1600[On Request]103030201531.5413078
2000-3150[On Request]1030302015[On Request][On Request][On Request]78
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LZZQB8-35-G — click image to zoom / view original.

Product Overview

About This Product

LZZQB8-35-G

This is a 35 kV indoor single-phase current transformer whose dry epoxy resin casting is the defining feature: the solid insulation removes the oil-handling and leakage concerns of liquid-filled designs and suits it to enclosed switchgear. The winding architecture covers metering and protection duties, with accuracy classes 0.2(S), 0.5(S) and 5P available and a rated burden of 10 VA at 50/60 Hz.

Selection within the range turns on winding count: a single metering core, a metering-plus-protection combination, or a residual-voltage winding where earth-fault detection is needed. Compliance evidence and test documentation are available [On Request]. Typical deployment is in indoor substation bays for current measurement and protection.

Before energising, verify insulation resistance, polarity and ratio by handover test, earth the secondary at one point and follow the nameplate terminal diagram. The secondary must never be open-circuited while the primary is energised. DC or non-standard frequencies are outside its intended use. Ratio and accuracy-class variants, OEM branding and document packages are quoted on request, with weight and short-time ratings confirmed against the nameplate.

Other Models in This Series

Same product family, different ratings — compare before you specify.

LZZQB8-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer
35kV
Current Transformer50/60Hz

LZZQB8-35-Q

Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZQB8-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZQB8-35-Q) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
LZZQB8-35A Indoor Single-phase Epoxy Resin Casting Current Transformer
35kV
Current Transformer50/60Hz

LZZQB8-35A

Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZQB8-35A Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
LZZQB8-35B Indoor Single-phase Epoxy Resin Casting Current Transformer
35kV
Current Transformer50/60Hz

LZZQB8-35-B

Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZQB8-35B Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZQB8-35-B) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs