中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLZZQB8-35-Q
LZZQB8-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer
35kVLZZQB8-35-Q
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 35kV
Secondary Metering (1S1 - 1S2):5A/1A ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LZZQB8-35-Q

LZZQB8-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZQB8-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZQB8-35-Q) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.

Key Engineering Advantages

  • 35kV indoor epoxy cast current transformer
  • stable insulation performance and diversified matching schemes
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LZZQB8-35-Q

Electrical Parameters

Primary Rated Voltage (Un):35kV
Secondary Winding Currents:5A/1A
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Insulation Level (BIL):40.5/95/185kV
Environmental Class:Ambient: -5℃~+40℃
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

Indoor 35kV epoxy cast CT for metering/protection; 12/42/75kV insulation level.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeLZZQB8-35-QFactory nameplate marking
Primary Voltage35kVRated voltage test (IEC 61869-1/3)
Secondary Current5A/1ARatio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)40.5/95/185kVPower-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50/60HzPer IEC 61869-1
EnvironmentAmbient: -5℃~+40℃Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor MV switchgear panels
  • Metering and protection in 10kV systems
  • Revenue metering applications
  • Substations with epoxy cast CTs

Not Recommended For

  • Outdoor installations
  • Gas-insulated switchgear (GIS)
  • DC systems
  • High-voltage transmission lines (>35kV)

Topology & Wiring

connect primary P1/P2 in series with line. Secondary terminals 1S1/1S2 for metering, 2S1/2S2 for protection. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground one point of secondary circuit per IEC 61869-2.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the insulation level?

A: 12/42/75kV means 12kV system, power-frequency withstand 42kV, lightning impulse 75kV peak.

Q: Can it be used outdoors?

A: No, it's indoor type only.

Q: What are the secondary ratings?

A: Secondary current is 5A or 1A.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LZZQB8-35-Q
11 cols · 9 rows

LZZBJ9-35 (Q) LZZQB8-35 (Q) Current Transformer

Rated primary current I1n (A)Accuracy classCombinedAccuracy class & rated output (VA) COSΦ=0.8Accuracy class & rated output (VA) COSΦ=0.8Accuracy class & rated output (VA) COSΦ=0.8Accuracy class & rated output (VA) COSΦ=0.8Accuracy class & rated output (VA) COSΦ=0.8Short-time thermal current Ith (kA/S)Short-time thermal current Ith (kA/S)Rated dynamic current Idyn (kA)Weight (kg) Weight
200.2(S)/0.5(S)1030302015411084
30-400.2(S)/0.5(S)1030302015421084
500.2(S)/5P10303020151213084
750.5(S)/5P10303020151614084
100-1500.5(S)/5P10303020152516384
200-3000.2/5P/5P103030201531.518084
400-6000.2/5P/5P103030201531.528084
800-16000.5/5P/5P103030201531.5413084
2000-31500.5/5P/5P1030302015[On Request][On Request][On Request]84
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LZZQB8-35-Q — click image to zoom / view original.

Product Overview

About This Product

LZZQB8-35-Q

The LZZQB8-35(Q) is a 35 kV indoor single-phase epoxy resin cast current transformer, engineered for revenue metering and protection in medium-voltage systems. Its accuracy classes of 0.2(S) / 0.5(S) / 5P and 10 VA rated burden support precise energy accounting and dependable relay operation.

Dry epoxy resin casting gives the unit compact dimensions and a small installation footprint, helping conserve switchgear cabinet space and simplify substation layout. The insulation level of 40.5/95/185 kV, together with 50/60 Hz frequency compatibility, provides the dielectric withstand needed for indoor service. Short-time thermal current and dynamic stability ratings vary by primary current; refer to the nameplate or official datasheet for the exact figures.

Compliance follows the IEC 61869 series, with type test reports and routine test certificates available [On Request]. Typical deployment is in indoor substation bays for busbar voltage measurement and protection. Earth the secondary at one point and equalise potentials before commissioning; never open-circuit the secondary while energised. This indoor CT is not suitable for outdoor open-air installation, where a dedicated outdoor model should be used. OEM and private-label options, custom ratios and accuracy classes, and document packages are available on request.

Other Models in This Series

Same product family, different ratings — compare before you specify.

LZZQB8-35A Indoor Single-phase Epoxy Resin Casting Current Transformer
35kV
Current Transformer50/60Hz

LZZQB8-35A

Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZQB8-35A Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
LZZQB8-35B Indoor Single-phase Epoxy Resin Casting Current Transformer
35kV
Current Transformer50/60Hz

LZZQB8-35-B

Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZQB8-35B Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZQB8-35-B) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
LZZQB8-35G Indoor Single-phase Epoxy Resin Casting Current Transformer
35kV
Current Transformer50/60Hz

LZZQB8-35-G

Indoor Single-phase Epoxy Resin Casting Current Transformer

Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards; rated insulation level 40.5/95/185kV, rated frequency 50/60Hz, rated secondary current 5A or 1A. Optional primary current covers 20–3150A; accuracy-class rated outputs:10VA(0.2S/0.5S),30VA(0.5),30VA(5P10),20VA(5P15),15VA(5P20); short-time thermal current ranges 4–31.5kA, rated dynamic stable current ranges 10–130kA; product weight:78kg; ambient operating temperature -5℃~+40℃.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs