KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsVT / PT
Product category

Voltage Transformer (VT) / Potential Transformer (PT)

Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.

225 models

Representative Models

JDZW1-35 Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZW1-35

Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV

JDZW1-35 Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.

Accuracy Class0.2/0.5/1.0
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
JDZX9-35 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX9-35

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX9-35 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P), rated burden 40VA / 90VA / 150VA / 100VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/6P(3P),0.5/6P(3P),1.0/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden40VA / 90VA / 150VA / 100VA
View Specs
JDZX18-6R Indoor Single-phase Epoxy Resin Casting Voltage Transformer
6kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZX18-6R

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX18-6R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 6kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JDZXW1-35 Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZXW1-35

Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV

Outdoor single-phase epoxy resin casting voltage transformer, 35kV rated, compact design, for voltage measurement and protection in power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, good weather resistance, anti-UV, suitable for outdoor installation. Accuracy classes: 0.2, 0.5, 1.0, 3P. Customizable ratios and specifications.

Accuracy Class0.2/0.5/1.0/3P
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
JDZ18-6DR Indoor Single-phase Epoxy Resin Casting Voltage Transformer
6kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZ18-6DR

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZ18-6DR is an indoor single-phase epoxy resin casting voltage transformer for 6kV systems, with a rated voltage ratio of 6/0.1/0.22kV and insulation level 7.2/32/60kV. Accuracy-class rated outputs are 50VA (class 0.2), 100VA (class 0.5) and 150VA (class 1.0), with a maximum output of 1600VA; the unit weighs 70kg and operates at 50/60Hz in ambient temperatures from -5°C to +40°C. Design and testing follow GB/T 20840.1/3 and IEC 61869-1/3.

Accuracy Class0.2/0.5/1.0
Insulation TypeDry Epoxy Resin
Rated Burden50VA(0.2), 100VA(0.5), 150VA(1.0)
ComplianceGB/T 20840.1/3
View Specs
JDZW3-35R2 Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV with 2 Fuses
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZW3-35R2

Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV with 2 Fuses

Outdoor single-phase epoxy resin casting voltage transformer with 2 primary fuses, 35kV rated, for voltage measurement and protection in power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, good weather resistance, anti-UV, suitable for outdoor installation. Accuracy classes: 0.2, 0.5, 1.0. Customizable ratios and specifications.

Accuracy Class0.2/0.5/1.0
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
JDZX9-35G Indoor Single-phase Epoxy Resin Casting Voltage Transformer
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX9-35G

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX9-35G Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2/3P(6P),0.5/3P(6P), rated burden 30VA / 90VA / 100VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/3P(6P),0.5/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden30VA / 90VA / 100VA
View Specs
JDZX9-35R Indoor Single-phase Epoxy Resin Casting Voltage Transformer
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX9-35R

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX9-35R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P), rated burden 30VA / 90VA / 150VA / 100VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/6P(3P),0.5/6P(3P),1.0/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden30VA / 90VA / 150VA / 100VA
View Specs
JDZX9-35DG2 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX9-35DG2

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX9-35DG2 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, 3P(6P), rated burden 60VA / 120VA / 200VA / 100VA / 1000VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2, 0.5, 1.0, 3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden60VA / 120VA / 200VA / 100VA / 1000VA
View Specs
JDZXF10-35R Indoor Single-phase Epoxy Resin Casting Voltage Transformer
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZXF10-35R

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZXF10-35R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2/0.2/6P(3P),0.5/0.5/6P(3P),0.2/0.5/6P(3P), rated burden 30VA / 40VA / 100VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/0.2/6P(3P),0.5/0.5/6P(3P),0.2/0.5/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden30VA / 40VA / 100VA
View Specs
JDZXF15-35LR-CQ Indoor Single-phase Isolated Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz / 60Hz

JDZXF15-35LR-CQ

Indoor Single-phase Isolated Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer

JDZXF15-35LR-CQ Indoor Single-phase Isolated Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2/0.5/3P(6P), rated burden 30VA(0.2),40VA(0.5),40VA(1.0),100VA(3P). Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz / 60Hz operation.

Accuracy Class0.2/0.5/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden30VA(0.2),40VA(0.5),40VA(1.0),100VA(3P)
View Specs
JDZXF15-35R-CQ Indoor Single-phase Isolated Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz / 60Hz

JDZXF15-35R-CQ

Indoor Single-phase Isolated Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer

JDZXF15-35R-CQ Indoor Single-phase Isolated Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2/0.5/3P(6P), rated burden 30VA(0.2),40VA(0.5),40VA(1.0),100VA(3P). Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz / 60Hz operation.

Accuracy Class0.2/0.5/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden30VA(0.2),40VA(0.5),40VA(1.0),100VA(3P)
View Specs
← Prev123…19Next →
Browse full catalogue