Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.
225 models
Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV
JDZW1-35 Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZX9-35 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P), rated burden 40VA / 90VA / 150VA / 100VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZX18-6R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 6kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV
Outdoor single-phase epoxy resin casting voltage transformer, 35kV rated, compact design, for voltage measurement and protection in power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, good weather resistance, anti-UV, suitable for outdoor installation. Accuracy classes: 0.2, 0.5, 1.0, 3P. Customizable ratios and specifications.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZ18-6DR is an indoor single-phase epoxy resin casting voltage transformer for 6kV systems, with a rated voltage ratio of 6/0.1/0.22kV and insulation level 7.2/32/60kV. Accuracy-class rated outputs are 50VA (class 0.2), 100VA (class 0.5) and 150VA (class 1.0), with a maximum output of 1600VA; the unit weighs 70kg and operates at 50/60Hz in ambient temperatures from -5°C to +40°C. Design and testing follow GB/T 20840.1/3 and IEC 61869-1/3.
Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV with 2 Fuses
Outdoor single-phase epoxy resin casting voltage transformer with 2 primary fuses, 35kV rated, for voltage measurement and protection in power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, good weather resistance, anti-UV, suitable for outdoor installation. Accuracy classes: 0.2, 0.5, 1.0. Customizable ratios and specifications.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZX9-35G Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2/3P(6P),0.5/3P(6P), rated burden 30VA / 90VA / 100VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZX9-35R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P), rated burden 30VA / 90VA / 150VA / 100VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZX9-35DG2 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, 3P(6P), rated burden 60VA / 120VA / 200VA / 100VA / 1000VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZXF10-35R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2/0.2/6P(3P),0.5/0.5/6P(3P),0.2/0.5/6P(3P), rated burden 30VA / 40VA / 100VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Isolated Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer
JDZXF15-35LR-CQ Indoor Single-phase Isolated Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2/0.5/3P(6P), rated burden 30VA(0.2),40VA(0.5),40VA(1.0),100VA(3P). Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz / 60Hz operation.
Indoor Single-phase Isolated Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer
JDZXF15-35R-CQ Indoor Single-phase Isolated Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2/0.5/3P(6P), rated burden 30VA(0.2),40VA(0.5),40VA(1.0),100VA(3P). Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz / 60Hz operation.