Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.
225 models
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZXF18-10R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Indoor Three-phase Epoxy Resin Casting Voltage Transformer
JSZV18-6R Indoor Three-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 6kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZ9-35A Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2,0.5,1.0, rated burden 50VA / 120VA / 250VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZ10-35R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2,0.5,1.0, rated burden 45VA / 100VA / 200VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Isolated Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer
Isolation-structure indoor VT with built-in fuse, compliant with GB/T20840.1/3 & IEC61869-1/3; insulation level 40.5/95/200kV, matched XRNP□-40.5 fuse 0.5A 50kA, net weight 75kg.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZX10-35R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P), rated burden 60VA / 150VA / 300VA / 100VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZX11-35R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, 3P(6P), rated burden 45VA / 100VA / 200VA / 100VA / 600VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZF9-35A Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, rated burden 20VA / 40VA / 60VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZ9-35Q Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2,0.5,1.0, rated burden 60VA / 150VA / 300VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Metal Armoured Epoxy Resin Casting Voltage Transformer
Indoor single-phase metal armoured epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 40.5/95/200kV, suitable for 50Hz/60Hz power systems, aluminum shell full grounding design, net weight 60kg.
Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer
Indoor single-phase built-in fuse metal armoured epoxy casting voltage transformer complying with GB/T20840.1/3 & IEC61869-1/3; rated insulation level 40.5/95/200kV, matched XRNP□-40.5 fuse (0.5A,50kA), net weight 75kg.
Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer
Indoor single-phase fuse-integrated metal armoured epoxy casting VT complying with GB/T20840.1/3 & IEC61869-1/3; rated insulation level 40.5/95/200kV, matched XRNP□-40.5 fuse (0.5A,50kA), net weight 75kg.