KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsVT / PT
Product category

Voltage Transformer (VT) / Potential Transformer (PT)

Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.

225 models

Representative Models

JDZXF18-10R Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZXF18-10R

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZXF18-10R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JSZV18-6R Indoor Three-phase Epoxy Resin Casting Voltage Transformer
6kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JSZV18-6R

Indoor Three-phase Epoxy Resin Casting Voltage Transformer

JSZV18-6R Indoor Three-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 6kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JDZ9-35A Indoor Single-phase Epoxy Resin Casting Voltage Transformer
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZ9-35A

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZ9-35A Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2,0.5,1.0, rated burden 50VA / 120VA / 250VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2,0.5,1.0
Insulation TypeDry Epoxy Resin
Rated Burden50VA / 120VA / 250VA
View Specs
JDZ10-35R Indoor Single-phase Epoxy Resin Casting Voltage Transformer
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZ10-35R

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZ10-35R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2,0.5,1.0, rated burden 45VA / 100VA / 200VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2,0.5,1.0
Insulation TypeDry Epoxy Resin
Rated Burden45VA / 100VA / 200VA
View Specs
JDZXF9-35AR-CQ Indoor Single-phase Isolated Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz / 60Hz

JDZXF9-35AR-CQ

Indoor Single-phase Isolated Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer

Isolation-structure indoor VT with built-in fuse, compliant with GB/T20840.1/3 & IEC61869-1/3; insulation level 40.5/95/200kV, matched XRNP□-40.5 fuse 0.5A 50kA, net weight 75kg.

Accuracy Class0.2/0.5/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden15VA(0.2),30VA(0.5),40VA(1.0),100VA(3P)
View Specs
JDZX10-35R Indoor Single-phase Epoxy Resin Casting Voltage Transformer
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX10-35R

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX10-35R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P), rated burden 60VA / 150VA / 300VA / 100VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/6P(3P),0.5/6P(3P),1.0/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden60VA / 150VA / 300VA / 100VA
View Specs
JDZX11-35R Indoor Single-phase Epoxy Resin Casting Voltage Transformer
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX11-35R

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX11-35R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, 3P(6P), rated burden 45VA / 100VA / 200VA / 100VA / 600VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2, 0.5, 1.0, 3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden45VA / 100VA / 200VA / 100VA / 600VA
View Specs
JDZF9-35A Indoor Single-phase Epoxy Resin Casting Voltage Transformer
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZF9-35A

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZF9-35A Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, rated burden 20VA / 40VA / 60VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2, 0.5
Insulation TypeDry Epoxy Resin
Rated Burden20VA / 40VA / 60VA
View Specs
JDZ9-35Q Indoor Single-phase Epoxy Resin Casting Voltage Transformer
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZ9-35Q

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZ9-35Q Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2,0.5,1.0, rated burden 60VA / 150VA / 300VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2,0.5,1.0
Insulation TypeDry Epoxy Resin
Rated Burden60VA / 150VA / 300VA
View Specs
JDZX15-35A2-CQ Indoor Single-phase Metal Armoured Epoxy Resin Casting Voltage Transformer
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz / 60Hz

JDZX15-35A2-CQ

Indoor Single-phase Metal Armoured Epoxy Resin Casting Voltage Transformer

Indoor single-phase metal armoured epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 40.5/95/200kV, suitable for 50Hz/60Hz power systems, aluminum shell full grounding design, net weight 60kg.

Accuracy Class0.2/3P(6P)、0.5/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden30VA(0.2),60VA(0.5),150VA(1.0),100VA(3P)
View Specs
JDZX15-35ALR-CQ Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz / 60Hz

JDZX15-35ALR-CQ

Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer

Indoor single-phase built-in fuse metal armoured epoxy casting voltage transformer complying with GB/T20840.1/3 & IEC61869-1/3; rated insulation level 40.5/95/200kV, matched XRNP□-40.5 fuse (0.5A,50kA), net weight 75kg.

Accuracy Class0.2/3P(6P)、0.5/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden30VA(0.2),60VA(0.5),150VA(1.0),100VA(3P)
View Specs
JDZX15-35AR-CQ Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz / 60Hz

JDZX15-35AR-CQ

Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer

Indoor single-phase fuse-integrated metal armoured epoxy casting VT complying with GB/T20840.1/3 & IEC61869-1/3; rated insulation level 40.5/95/200kV, matched XRNP□-40.5 fuse (0.5A,50kA), net weight 75kg.

Accuracy Class0.2/3P(6P)、0.5/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden30VA(0.2),60VA(0.5),150VA(1.0),100VA(3P)
View Specs