Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.
225 models
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZXF9-35G Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2/0.2/3P(6P),0.2/0.5/3P(6P), rated burden 15VA / 20VA / 100VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV
Outdoor single-phase epoxy resin casting voltage transformer, 35kV rated, for voltage measurement and protection in power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, good weather resistance, anti-UV, suitable for outdoor installation. Accuracy classes: 0.2, 0.5, 1.0, 3P. Customizable ratios and specifications.
Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV
JDZW3-35 Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer
JDZX15-35LR-CQ Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2/3P(6P)、0.5/3P(6P), rated burden 60VA(0.2),120VA(0.5),180VA(1.0),100VA(3P). Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz / 60Hz operation.
Indoor Single-phase Isolated Metal Armoured Epoxy Resin Casting Voltage Transformer
Indoor isolated structure metal armoured epoxy casting voltage transformer, meets GB/T20840.1/3 & IEC61869-1/3 standards; insulation level 40.5/95/200kV, shell full-grounding design, net weight 75kg.
35kV Indoor Epoxy Cast Voltage Transformer for State Grid Metering & Earth Fault Protection
35kV indoor epoxy resin cast voltage transformer for power grid metering. Grounded type design with dual windings for metering and protection. Rated insulation level 40.5/95/200kV, 50/60Hz. Compliant with IEC 61869 and GB/T 20840 standards. Vacuum epoxy casting, excellent insulation performance, low partial discharge. Suitable for 35kV grounded neutral systems. Customizable voltage ratio and accuracy class.
Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV
Outdoor single-phase epoxy resin casting voltage transformer with residual winding, 35kV rated, for voltage measurement and protection in power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, good weather resistance, anti-UV, suitable for outdoor installation. Accuracy classes: 0.2, 0.5, 3P. Customizable ratios and specifications.
Outdoor Epoxy Resin Voltage Transformer 35kV with Residual Winding & 1 Fuse
Outdoor single-phase epoxy resin casting voltage transformer with residual winding and 1 primary fuse, 35kV rated, for voltage measurement and protection in power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, good weather resistance, anti-UV, suitable for outdoor installation. Accuracy classes: 0.2, 0.5, 3P. Customizable ratios and specifications.
Outdoor Epoxy Resin Voltage Transformer 35kV with Residual Winding & 2 Fuses
Outdoor single-phase epoxy resin casting voltage transformer with residual winding and 2 primary fuses, 35kV rated, for voltage measurement and protection in power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, good weather resistance, anti-UV, suitable for outdoor installation. Accuracy classes: 0.2, 0.5, 3P. Customizable ratios and specifications.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZX18-10R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer
JDZX15-35R-CQ Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2/3P(6P)、0.5/3P(6P), rated burden 60VA(0.2),120VA(0.5),180VA(1.0),100VA(3P). Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz / 60Hz operation.
Indoor Single-phase Isolated Metal Armoured Epoxy Resin Casting Voltage Transformer
Indoor isolated-structure metal armoured epoxy casting voltage transformer, compliant with GB/T20840.1/3 & IEC61869-1/3; rated insulation level 40.5/95/200kV, shell full-grounding design, net weight 60kg.