KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsVT / PT
Product category

Voltage Transformer (VT) / Potential Transformer (PT)

Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.

225 models

Representative Models

JDZXF9-35G Indoor Single-phase Epoxy Resin Casting Voltage Transformer
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZXF9-35G

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZXF9-35G Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2/0.2/3P(6P),0.2/0.5/3P(6P), rated burden 15VA / 20VA / 100VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/0.2/3P(6P),0.2/0.5/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden15VA / 20VA / 100VA
View Specs
JDZXW-35D Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZXW-35D

Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV

Outdoor single-phase epoxy resin casting voltage transformer, 35kV rated, for voltage measurement and protection in power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, good weather resistance, anti-UV, suitable for outdoor installation. Accuracy classes: 0.2, 0.5, 1.0, 3P. Customizable ratios and specifications.

Accuracy Class0.2/0.5/1.0/3P
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
JDZW3-35 Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZW3-35

Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV

JDZW3-35 Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.

Accuracy Class0.2/0.5/1.0
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
JDZX15-35LR-CQ Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz / 60Hz

JDZX15-35LR-CQ

Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer

JDZX15-35LR-CQ Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2/3P(6P)、0.5/3P(6P), rated burden 60VA(0.2),120VA(0.5),180VA(1.0),100VA(3P). Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz / 60Hz operation.

Accuracy Class0.2/3P(6P)、0.5/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden60VA(0.2),120VA(0.5),180VA(1.0),100VA(3P)
View Specs
JDZXF9-35A1-CQ Indoor Single-phase Isolated Metal Armoured Epoxy Resin Casting Voltage Transformer
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz / 60Hz

JDZXF9-35A1-CQ

Indoor Single-phase Isolated Metal Armoured Epoxy Resin Casting Voltage Transformer

Indoor isolated structure metal armoured epoxy casting voltage transformer, meets GB/T20840.1/3 & IEC61869-1/3 standards; insulation level 40.5/95/200kV, shell full-grounding design, net weight 75kg.

Accuracy Class0.2/0.5/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden15VA(0.2),20VA(0.5),100VA(3P)
View Specs
JDZXN-35 35kV Indoor Epoxy Cast Voltage Transformer for State Grid Metering & Earth Fault Protection
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZXN-35

35kV Indoor Epoxy Cast Voltage Transformer for State Grid Metering & Earth Fault Protection

35kV indoor epoxy resin cast voltage transformer for power grid metering. Grounded type design with dual windings for metering and protection. Rated insulation level 40.5/95/200kV, 50/60Hz. Compliant with IEC 61869 and GB/T 20840 standards. Vacuum epoxy casting, excellent insulation performance, low partial discharge. Suitable for 35kV grounded neutral systems. Customizable voltage ratio and accuracy class.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869
View Specs
JDZXW1-35G Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZXW1-35G

Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV

Outdoor single-phase epoxy resin casting voltage transformer with residual winding, 35kV rated, for voltage measurement and protection in power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, good weather resistance, anti-UV, suitable for outdoor installation. Accuracy classes: 0.2, 0.5, 3P. Customizable ratios and specifications.

Accuracy Class0.2/0.5/3P
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
JDZXW3-35GR1 Outdoor Epoxy Resin Voltage Transformer 35kV with Residual Winding & 1 Fuse
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZXW3-35GR1

Outdoor Epoxy Resin Voltage Transformer 35kV with Residual Winding & 1 Fuse

Outdoor single-phase epoxy resin casting voltage transformer with residual winding and 1 primary fuse, 35kV rated, for voltage measurement and protection in power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, good weather resistance, anti-UV, suitable for outdoor installation. Accuracy classes: 0.2, 0.5, 3P. Customizable ratios and specifications.

Accuracy Class0.2/0.5/3P
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
JDZXW3-35GR2 Outdoor Epoxy Resin Voltage Transformer 35kV with Residual Winding & 2 Fuses
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZXW3-35GR2

Outdoor Epoxy Resin Voltage Transformer 35kV with Residual Winding & 2 Fuses

Outdoor single-phase epoxy resin casting voltage transformer with residual winding and 2 primary fuses, 35kV rated, for voltage measurement and protection in power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, good weather resistance, anti-UV, suitable for outdoor installation. Accuracy classes: 0.2, 0.5, 3P. Customizable ratios and specifications.

Accuracy Class0.2/0.5/3P
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
JDZX18-10R Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZX18-10R

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX18-10R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JDZX15-35R-CQ Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz / 60Hz

JDZX15-35R-CQ

Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer

JDZX15-35R-CQ Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2/3P(6P)、0.5/3P(6P), rated burden 60VA(0.2),120VA(0.5),180VA(1.0),100VA(3P). Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz / 60Hz operation.

Accuracy Class0.2/3P(6P)、0.5/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden60VA(0.2),120VA(0.5),180VA(1.0),100VA(3P)
View Specs
JDZXF9-35A2-CQ Indoor Single-phase Isolated Metal Armoured Epoxy Resin Casting Voltage Transformer
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz / 60Hz

JDZXF9-35A2-CQ

Indoor Single-phase Isolated Metal Armoured Epoxy Resin Casting Voltage Transformer

Indoor isolated-structure metal armoured epoxy casting voltage transformer, compliant with GB/T20840.1/3 & IEC61869-1/3; rated insulation level 40.5/95/200kV, shell full-grounding design, net weight 60kg.

Accuracy Class0.2/0.5/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden15VA(0.2),30VA(0.5),40VA(1.0),100VA(3P)
View Specs
← Prev123456…19Next →
Browse full catalogue