Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.
225 models
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZX9-20-15 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2/6P,0.5/6P,1.0/6P, rated burden 60VA / 150VA / 300VA / 150VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZX9-20-15AG Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P), rated burden 30VA / 60VA / 100VA / 100VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZX9-20-15D Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P), rated burden 100VA / 180VA / 250VA / 150VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZ9-20-15D Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2,0.5,1.0, rated burden 100VA / 200VA / 400VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZX9-20-15DG Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P), rated burden 80VA / 150VA / 250VA / 150VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Outdoor Single-phase Silicone Rubber Voltage Transformer 20kV 15kV
Outdoor single-phase silicone rubber composite insulation voltage transformer, 20kV/15kV rated, for voltage measurement and protection in distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Silicone rubber construction, excellent weather resistance, anti-UV, anti-pollution, suitable for harsh outdoor environments. Accuracy classes: 0.2, 0.5, 1.0. Customizable ratios and specs.
Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 20kV 15kV
Outdoor single-phase epoxy resin casting voltage transformer, 20kV/15kV rated, for voltage measurement and protection in power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, good weather resistance, anti-UV, suitable for outdoor installation. Accuracy classes: 0.2, 0.5, 1.0. Customizable ratios and specifications.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZXF9-20-15DG Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2/0.2/6P(3P),0.2/0.5/6P(3P), rated burden 30VA / 50VA / 150VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZXF9-20-15G Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2/0.2/6P(3P),0.2/0.5/6P(3P), rated burden 30VA / 30VA / 100VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZU11-20-15 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2,0.5, rated burden 30VA / 60VA / 100VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 20kV 15kV with 2 Fuses
Outdoor single-phase epoxy resin casting voltage transformer with 2 primary fuses, 20kV/15kV rated, for voltage measurement and protection in power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, good weather resistance, anti-UV, suitable for outdoor installation. Accuracy classes: 0.2, 0.5, 1.0. Customizable ratios and specifications.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZF9-20-15D Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, rated burden 50VA / 50VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.