KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsVT / PT
Product category

Voltage Transformer (VT) / Potential Transformer (PT)

Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.

225 models

Representative Models

JDZX9-20-15 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
20kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX9-20-15

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX9-20-15 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2/6P,0.5/6P,1.0/6P, rated burden 60VA / 150VA / 300VA / 150VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/6P,0.5/6P,1.0/6P
Insulation TypeDry Epoxy Resin
Rated Burden60VA / 150VA / 300VA / 150VA
View Specs
JDZX9-20-15AG Indoor Single-phase Epoxy Resin Casting Voltage Transformer
20kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX9-20-15AG

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX9-20-15AG Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P), rated burden 30VA / 60VA / 100VA / 100VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/6P(3P),0.5/6P(3P),1.0/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden30VA / 60VA / 100VA / 100VA
View Specs
JDZX9-20-15D Indoor Single-phase Epoxy Resin Casting Voltage Transformer
20kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX9-20-15D

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX9-20-15D Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P), rated burden 100VA / 180VA / 250VA / 150VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/6P(3P),0.5/6P(3P),1.0/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden100VA / 180VA / 250VA / 150VA
View Specs
JDZ9-20-15D Indoor Single-phase Epoxy Resin Casting Voltage Transformer
20kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZ9-20-15D

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZ9-20-15D Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2,0.5,1.0, rated burden 100VA / 200VA / 400VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2,0.5,1.0
Insulation TypeDry Epoxy Resin
Rated Burden100VA / 200VA / 400VA
View Specs
JDZX9-20-15DG Indoor Single-phase Epoxy Resin Casting Voltage Transformer
20kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX9-20-15DG

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX9-20-15DG Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P), rated burden 80VA / 150VA / 250VA / 150VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/6P(3P),0.5/6P(3P),1.0/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden80VA / 150VA / 250VA / 150VA
View Specs
JDZW6-20 15 Outdoor Single-phase Silicone Rubber Voltage Transformer 20kV 15kV
20kV/15kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZW6-20-15

Outdoor Single-phase Silicone Rubber Voltage Transformer 20kV 15kV

Outdoor single-phase silicone rubber composite insulation voltage transformer, 20kV/15kV rated, for voltage measurement and protection in distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Silicone rubber construction, excellent weather resistance, anti-UV, anti-pollution, suitable for harsh outdoor environments. Accuracy classes: 0.2, 0.5, 1.0. Customizable ratios and specs.

Accuracy Class0.2/0.5/1.0
Insulation TypeSilicone Rubber
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
JDZW-20 15 Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 20kV 15kV
20kV/15kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZW-20-15

Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 20kV 15kV

Outdoor single-phase epoxy resin casting voltage transformer, 20kV/15kV rated, for voltage measurement and protection in power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, good weather resistance, anti-UV, suitable for outdoor installation. Accuracy classes: 0.2, 0.5, 1.0. Customizable ratios and specifications.

Accuracy Class0.2/0.5/1.0
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
JDZXF9-20-15DG Indoor Single-phase Epoxy Resin Casting Voltage Transformer
20kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZXF9-20-15DG

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZXF9-20-15DG Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2/0.2/6P(3P),0.2/0.5/6P(3P), rated burden 30VA / 50VA / 150VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/0.2/6P(3P),0.2/0.5/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden30VA / 50VA / 150VA
View Specs
JDZXF9-20-15G Indoor Single-phase Epoxy Resin Casting Voltage Transformer
20kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZXF9-20-15G

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZXF9-20-15G Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2/0.2/6P(3P),0.2/0.5/6P(3P), rated burden 30VA / 30VA / 100VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/0.2/6P(3P),0.2/0.5/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden30VA / 30VA / 100VA
View Specs
JDZU11-20-15 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
20kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZU11-20-15

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZU11-20-15 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2,0.5, rated burden 30VA / 60VA / 100VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2,0.5
Insulation TypeDry Epoxy Resin
Rated Burden30VA / 60VA / 100VA
View Specs
JDZW-20 15R2 Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 20kV 15kV with 2 Fuses
20kV/15kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZW-20-15R2

Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 20kV 15kV with 2 Fuses

Outdoor single-phase epoxy resin casting voltage transformer with 2 primary fuses, 20kV/15kV rated, for voltage measurement and protection in power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, good weather resistance, anti-UV, suitable for outdoor installation. Accuracy classes: 0.2, 0.5, 1.0. Customizable ratios and specifications.

Accuracy Class0.2/0.5/1.0
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
JDZF9-20-15D Indoor Single-phase Epoxy Resin Casting Voltage Transformer
20kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZF9-20-15D

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZF9-20-15D Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, rated burden 50VA / 50VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2, 0.5
Insulation TypeDry Epoxy Resin
Rated Burden50VA / 50VA
View Specs