Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.
225 models
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZXF9-20-15 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2/0.2/6P,0.2/0.5/6P, rated burden 30VA / 40VA / 100VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZXF9-20-15AG Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2/0.5/6P(3P), rated burden 15VA / 15VA / 100VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZXF9-20-15D Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2/0.2/6P(3P),0.2/0.5/6P(3P), rated burden 50VA / 50VA / 150VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Metal Armoured Epoxy Resin Casting Voltage Transformer
JDZXM15-6R-CQ Indoor Single-phase Metal Armoured Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 15kV/6kV, accuracy class 0.2 / 0.5. Design: insulation level 7.2/32/60kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Metal Armoured Epoxy Resin Casting Voltage Transformer
Indoor single-phase metal armoured epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 18/55/105kV, 50Hz/60Hz applicable, aluminum shell full grounding structure.
Indoor Single-phase Metal Armoured Epoxy Resin Casting Voltage Transformer
JDZXM15-10R-CQ Indoor Single-phase Metal Armoured Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 15kV/10kV, accuracy class 0.2 / 0.5. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.
Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 15kV
Outdoor single-phase epoxy resin casting voltage transformer, 15kV rated, for voltage measurement and protection in power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, good weather resistance, anti-UV, suitable for outdoor installation. Accuracy classes: 0.2, 0.5, 3P. Customizable ratios and specifications.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZ10-10-6AJIII Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV/6kV, accuracy class 0.2S FS10 / 0.2 FS10 / 0.5S FS10, 0.5FS10, 5P10/10P10, 5P15/10P15, 5P20/10P20, 5P30/10P30. Design: Dry Epoxy Resin, 50/60Hz operation.
Outdoor Single-phase Silicone Rubber Voltage Transformer 10kV 6kV with 1 Fuse
JDZW6-10 6R1 Outdoor Single-phase Silicone Rubber Voltage Transformer 10kV 6kV with 1 Fuse (JDZW6-10-6R1) is designed for metering and protection in power systems. Key ratings: primary voltage 10kV/6kV, accuracy class 0.2/0.5/1.0. Design: Silicone Rubber, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
10kV Outdoor Single-Phase Silicone Rubber Voltage Transformer
Outdoor single-phase silicone rubber insulated voltage transformer for 10kV/6kV systems. Composite insulation design with excellent weather resistance. Rated insulation level 12/42/75kV and 7.2/32/60kV. Compliant with IEC 61869 and GB/T 20840 standards. Multiple accuracy class combinations: 0.2, 0.5, 1.0. Rated output up to 80VA, secondary thermal limiting output 500VA. Without primary fuse, UV resistant, anti-pollution, suitable for outdoor pole-mounted installation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZ11-10-6B Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2,0.5,1.0 /0.2/0.5, rated burden 30VA / 80VA / 150VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZJ-10-6G Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, 6P(3P), rated burden 15VA / 40VA / 80VA / 50VA / 400VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.