Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.
225 models
Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 10kV 6kV with 2 Fuses
JDZW2-10 6RGY Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 10kV 6kV with 2 Fuses (JDZW2-10-6RGY) is designed for metering and protection in power systems. Key ratings: primary voltage 10kV/6kV, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
JDZX10-10-6B Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZX10-10-6B Indoor Single-phase Epoxy Resin Casting Voltage Transformer (JDZX10-10-6BG) is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P),0.2/0.5/6P(3P), rated burden 10VA / 15VA / 100VA / 50VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
10kV Indoor Epoxy Cast Built-in Voltage Transformer for Pole-Mounted Circuit Breaker
10kV/6kV indoor single-phase epoxy resin cast voltage transformer. Built-in type designed for pole-mounted circuit breakers and switchgear. Rated insulation level 12/42/75kV and 7.2/32/60kV. Rated frequency 50/60Hz. Compliant with IEC 61869 and GB/T 20840 standards. Vacuum epoxy casting process, low partial discharge, high accuracy. Provides voltage measurement and protection signals for switchgear. Customizable voltage ratio and accuracy class available.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZ-10-6B Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, rated burden 30VA / 60VA / 120VA / 600VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZ10-10-6A Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2,0.5,1.0, rated burden 15VA / 30VA / 60VA. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZ10-10-6AJ Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2,0.5,1.0, rated burden 20VA / 40VA / 60VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZ10-10-6AJII Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2,0.5,1.0 / 0.2/0.5, rated burden 15VA / 15VA / 90VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZ10-10-6AR Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2,0.5,1.0, rated burden 15VA / 30VA / 60VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZ10-10-6B Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2,0.5,1.0 /0.2/0.5, rated burden 20VA / 40VA / 80VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZ10-10-6C1 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2,0.5,1.0, rated burden 25VA / 60VA / 100VA / 200VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZ10-10-6R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2,0.5,1.0, rated burden 30VA / 50VA / 100VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZ10-10-6R2 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, rated burden 30VA / 50VA / 100VA / 600VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.