KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsVT / PT
Product category

Voltage Transformer (VT) / Potential Transformer (PT)

Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.

225 models

Representative Models

JDZX16-10-6W2G Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX16-10-6W2G

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX16-10-6W2G Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, 3P, rated burden 80VA / 150VA / 250VA / 100VA / 1200VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2, 0.5, 1.0, 3P
Insulation TypeDry Epoxy Resin
Rated Burden80VA / 150VA / 250VA / 100VA / 1200VA
View Specs
JSZF-10-6G Indoor Three-phase Anti-ferroresonance Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JSZF-10-6G

Indoor Three-phase Anti-ferroresonance Epoxy Resin Casting Voltage Transformer

JSZF-10-6G Indoor Three-phase Anti-ferroresonance Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, 6P(3P), rated burden 15VA / 30VA / 50VA / 100VA / 1000VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2, 0.5, 1.0, 6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden15VA / 30VA / 50VA / 100VA / 1000VA
View Specs
JDZX19-10-6G1 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX19-10-6G1

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX19-10-6G1 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/3P(6P),0.5/3P(6P),1.0/3P(6P), rated burden 75VA / 150VA / 100VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/3P(6P),0.5/3P(6P),1.0/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden75VA / 150VA / 100VA
View Specs
JDZX6-10-6RG2M Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX6-10-6RG2M

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX6-10-6RG2M Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, 3P(6P), rated burden 25VA / 60VA / 100VA / 100VA / 300VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2, 0.5, 1.0, 3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden25VA / 60VA / 100VA / 100VA / 300VA
View Specs
JDZX9-10-10DG Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX9-10-10DG

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX9-10-10DG Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P),0.2/0.5/6P(3P), rated burden 60VA / 75VA / 400VA / 150VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/6P(3P),0.5/6P(3P),1.0/6P(3P),0.2/0.5/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden60VA / 75VA / 400VA / 150VA
View Specs
JDZX9-10-10G1 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX9-10-10G1

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX9-10-10G1 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P),0.2/0.5/6P(3P), rated burden 300VA / 100VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/6P(3P),0.5/6P(3P),1.0/6P(3P),0.2/0.5/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden300VA / 100VA
View Specs
JDZX9-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX9-10-6

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX9-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P),0.2/0.5/6P(3P), rated burden 15VA / 20VA / 90VA / 50VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/6P(3P),0.5/6P(3P),1.0/6P(3P),0.2/0.5/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden15VA / 20VA / 90VA / 50VA
View Specs
JDZX9-10-6RG Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX9-10-6RG

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX9-10-6RG Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/3P(6P),0.5/3P(6P),1.0/3P(6P), rated burden 30VA / 75VA / 100VA / 100VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/3P(6P),0.5/3P(6P),1.0/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden30VA / 75VA / 100VA / 100VA
View Specs
JDZQN-10 10kV Indoor Epoxy Cast Voltage Transformer for State Grid Metering
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZQN-10

10kV Indoor Epoxy Cast Voltage Transformer for State Grid Metering

10kV indoor epoxy resin cast voltage transformer for State Grid metering. Dual windings for metering and residual voltage measurement. Rated insulation level 12/42/75kV, 50/60Hz. Compliant with IEC 61869 and GB/T 20840 standards. Vacuum epoxy casting process, low partial discharge, high accuracy. Non-grounded type design, suitable for ungrounded systems. Customizable voltage ratio and accuracy class available.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869
View Specs
JDZXF10-10-6R Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZXF10-10-6R

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZXF10-10-6R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/0.5/6P(3P), rated burden 10VA / 15VA / 50VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/0.5/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden10VA / 15VA / 50VA
View Specs
JDZXF16-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZXF16-10-6

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZXF16-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/0.5/3P(6P), rated burden 30VA / 40VA / 100VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/0.5/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden30VA / 40VA / 100VA
View Specs
JDZXF19-10-6G Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZXF19-10-6G

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZXF19-10-6G Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/0.5/3P(6P), rated burden 50VA / 60VA / 100VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/0.5/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden50VA / 60VA / 100VA
View Specs