Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.
225 models
Indoor Three-phase Epoxy Resin Casting Voltage Transformer
JSZV8-10-6R-C Indoor Three-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, rated burden 25VA / 50VA / 100VA / 400VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Outdoor Three-phase Silicone Rubber Voltage Transformer 10kV with Fuse
Outdoor three-phase silicone rubber composite insulation voltage transformer, 10kV rated, with primary fuse, for voltage measurement and protection in three-phase power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Silicone rubber construction, excellent weather resistance, anti-UV, anti-pollution, suitable for harsh outdoor environments. Accuracy classes: 0.2, 0.5, 3P. Customizable ratios and specifications.
Indoor Three-phase Epoxy Resin Casting Voltage Transformer
Indoor three-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 12/42/75kV, rated frequency 50/60Hz; product weight:105kg; ambient operating temperature -5℃~+40℃, multiple optional accuracy grades available.
Indoor Three-phase Epoxy Resin Casting Voltage Transformer
Indoor three-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 12/42/75kV, rated frequency 50/60Hz; product weight:130kg; ambient operating temperature -5℃~+40℃, multiple optional accuracy grades available.
Indoor Three-phase Epoxy Resin Casting Voltage Transformer
JSZY18-6FR-2 Indoor Three-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 6kV, accuracy class 0.2 / 0.5. Design: insulation level 7.2/32/60kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Three-phase Epoxy Resin Casting Voltage Transformer
JSZY18-6FR Indoor Three-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 6kV, accuracy class 0.2 / 0.5. Design: insulation level 7.2/32/60kV, Dry Epoxy Resin, 50/60Hz operation.
Outdoor Three-phase Epoxy Resin Casting Voltage Transformer 10kV
Outdoor three-phase epoxy resin casting voltage transformer, 10kV rated, for voltage measurement and protection in three-phase power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, good weather resistance, anti-UV, suitable for outdoor installation. Accuracy classes: 0.2, 0.5, 3P. Customizable ratios and specifications
Indoor Three-phase Epoxy Resin Casting Voltage Transformer
JSZV2-10-6R Indoor Three-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, rated burden 40VA / 80VA / 160VA / 600VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Three-phase Epoxy Resin Casting Voltage Transformer
JSZV8-10-6R-B Indoor Three-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, rated burden 25VA / 50VA / 100VA / 400VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZF51-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, rated burden 30VA / 50VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZJ-10-6BG Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, 3P(6P), rated burden 20VA / 50VA / 100VA / 100VA / 600VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Three-phase Anti-ferroresonance Epoxy Resin Casting Voltage Transformer
JSZJK-10-6R Indoor Three-phase Anti-ferroresonance Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, 6P(3P), rated burden 15VA / 30VA / 50VA / 100VA / 600VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.