KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsVT / PT
Product category

Voltage Transformer (VT) / Potential Transformer (PT)

Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.

225 models

Representative Models

JSZV8-10-6R-C Indoor Three-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JSZV8-10-6R-C

Indoor Three-phase Epoxy Resin Casting Voltage Transformer

JSZV8-10-6R-C Indoor Three-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, rated burden 25VA / 50VA / 100VA / 400VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2, 0.5, 1.0
Insulation TypeDry Epoxy Resin
Rated Burden25VA / 50VA / 100VA / 400VA
View Specs
JSZW-10WFR Outdoor Three-phase Silicone Rubber Voltage Transformer 10kV with Fuse
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JSZW-10WFR

Outdoor Three-phase Silicone Rubber Voltage Transformer 10kV with Fuse

Outdoor three-phase silicone rubber composite insulation voltage transformer, 10kV rated, with primary fuse, for voltage measurement and protection in three-phase power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Silicone rubber construction, excellent weather resistance, anti-UV, anti-pollution, suitable for harsh outdoor environments. Accuracy classes: 0.2, 0.5, 3P. Customizable ratios and specifications.

Accuracy Class0.2/0.5/3P
Insulation TypeSilicone Rubber
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
JSZY18-10R Indoor Three-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JSZY18-10R

Indoor Three-phase Epoxy Resin Casting Voltage Transformer

Indoor three-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 12/42/75kV, rated frequency 50/60Hz; product weight:105kg; ambient operating temperature -5℃~+40℃, multiple optional accuracy grades available.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JSZY18-10R3 Indoor Three-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JSZY18-10R3

Indoor Three-phase Epoxy Resin Casting Voltage Transformer

Indoor three-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 12/42/75kV, rated frequency 50/60Hz; product weight:130kg; ambient operating temperature -5℃~+40℃, multiple optional accuracy grades available.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JSZY18-6FR-2 Indoor Three-phase Epoxy Resin Casting Voltage Transformer
6kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JSZY18-6FR-2

Indoor Three-phase Epoxy Resin Casting Voltage Transformer

JSZY18-6FR-2 Indoor Three-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 6kV, accuracy class 0.2 / 0.5. Design: insulation level 7.2/32/60kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy Class0.2 / 0.5
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JSZY18-6FR Indoor Three-phase Epoxy Resin Casting Voltage Transformer
6kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JSZY18-6FR

Indoor Three-phase Epoxy Resin Casting Voltage Transformer

JSZY18-6FR Indoor Three-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 6kV, accuracy class 0.2 / 0.5. Design: insulation level 7.2/32/60kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy Class0.2 / 0.5
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JSZYW-10R Outdoor Three-phase Epoxy Resin Casting Voltage Transformer 10kV
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JSZYW-10R

Outdoor Three-phase Epoxy Resin Casting Voltage Transformer 10kV

Outdoor three-phase epoxy resin casting voltage transformer, 10kV rated, for voltage measurement and protection in three-phase power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, good weather resistance, anti-UV, suitable for outdoor installation. Accuracy classes: 0.2, 0.5, 3P. Customizable ratios and specifications

Accuracy Class0.2/0.5/3P
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
JSZV2-10-6R Indoor Three-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JSZV2-10-6R

Indoor Three-phase Epoxy Resin Casting Voltage Transformer

JSZV2-10-6R Indoor Three-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, rated burden 40VA / 80VA / 160VA / 600VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2, 0.5, 1.0
Insulation TypeDry Epoxy Resin
Rated Burden40VA / 80VA / 160VA / 600VA
View Specs
JSZV8-10-6R-B Indoor Three-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JSZV8-10-6R-B

Indoor Three-phase Epoxy Resin Casting Voltage Transformer

JSZV8-10-6R-B Indoor Three-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, rated burden 25VA / 50VA / 100VA / 400VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2, 0.5, 1.0
Insulation TypeDry Epoxy Resin
Rated Burden25VA / 50VA / 100VA / 400VA
View Specs
JDZF51-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZF51-10-6

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZF51-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, rated burden 30VA / 50VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2, 0.5
Insulation TypeDry Epoxy Resin
Rated Burden30VA / 50VA
View Specs
JDZJ-10-6BG Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZJ-10-6BG

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZJ-10-6BG Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, 3P(6P), rated burden 20VA / 50VA / 100VA / 100VA / 600VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2, 0.5, 1.0, 3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden20VA / 50VA / 100VA / 100VA / 600VA
View Specs
JSZJK-10-6R Indoor Three-phase Anti-ferroresonance Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JSZJK-10-6R

Indoor Three-phase Anti-ferroresonance Epoxy Resin Casting Voltage Transformer

JSZJK-10-6R Indoor Three-phase Anti-ferroresonance Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, 6P(3P), rated burden 15VA / 30VA / 50VA / 100VA / 600VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2, 0.5, 1.0, 6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden15VA / 30VA / 50VA / 100VA / 600VA
View Specs
← Prev1…1213141516…19Next →