KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsVT / PT
Product category

Voltage Transformer (VT) / Potential Transformer (PT)

Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.

225 models

Representative Models

JDZ11-10-6A Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZ11-10-6A

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZ11-10-6A Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2,0.5,1.0 /0.2/0.5, rated burden 20VA / 40VA / 60VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2,0.5,1.0 /0.2/0.5
Insulation TypeDry Epoxy Resin
Rated Burden20VA / 40VA / 60VA
View Specs
JDZ16-10-6W Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZ16-10-6W

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZ16-10-6W Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2,0.5, rated burden 40VA / 100VA / 200VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2,0.5
Insulation TypeDry Epoxy Resin
Rated Burden40VA / 100VA / 200VA
View Specs
JDZ16-10-6W2 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZ16-10-6W2

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZ16-10-6W2 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2,0.5, rated burden 80VA / 150VA / 250VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2,0.5
Insulation TypeDry Epoxy Resin
Rated Burden80VA / 150VA / 250VA
View Specs
JDZ18-10R Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10 kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZ18-10R

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

Indoor single-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 12/42/75kV, rated voltage ratio 10/0.1kV, rated frequency 50/60Hz; accuracy class rated output:30VA(0.2),60VA(0.5),100VA(1.0); limiting thermal output of secondary winding 600VA; product weight:31kg; ambient operating temperature -5℃~+40℃.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JDZ18-15R Indoor Single-phase Epoxy Resin Casting Voltage Transformer
15kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZ18-15R

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZ18-15R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 15kV, accuracy class 0.2 / 0.5. Design: insulation level 18/55/105kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy Class0.2 / 0.5
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JDZ3-10,6R 10kV Indoor Epoxy Cast Built-in Voltage Transformer R-Type for Pole-Mounted Circuit Breaker
10kV/6kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZ3-10-6R

10kV Indoor Epoxy Cast Built-in Voltage Transformer R-Type for Pole-Mounted Circuit Breaker

10kV/6kV indoor single-phase epoxy resin cast voltage transformer, R-type. Special R-type bushing design for pole-mounted circuit breaker integration. Rated insulation level 12/42/75kV and 7.2/32/60kV. Rated frequency 50/60Hz. Compliant with IEC 61869 and GB/T 20840 standards. Vacuum epoxy casting, compact design, easy installation in switchgear. Provides reliable voltage measurement and protection signals. Customizable voltage ratio and accuracy class.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869
View Specs
JDZX9-10-6AG Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX9-10-6AG

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX9-10-6AG Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P),0.2/0.5/6P(3P), rated burden 10VA / 10VA / 50VA / 50VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/6P(3P),0.5/6P(3P),1.0/6P(3P),0.2/0.5/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden10VA / 10VA / 50VA / 50VA
View Specs
JDZW-10 6GY Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 10kV 6kV
10kV/6kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZW-10-6GY

Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 10kV 6kV

JDZW-10 6GY Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 10kV 6kV (JDZW-10-6GY) is designed for metering and protection in power systems. Key ratings: primary voltage 10kV/6kV, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.

Accuracy Class0.2/0.5/1.0
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
JDZX15-15R-CQ Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer
15kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZX15-15R-CQ

Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer

JDZX15-15R-CQ Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 15kV, accuracy class 0.2/3P(6P)、0.5/3P(6P), rated burden 3×10VA(0.2),3×30VA(0.5),100VA(3P/6P). Design: insulation level 18/55/105kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy Class0.2/3P(6P)、0.5/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden3×10VA(0.2),3×30VA(0.5),100VA(3P/6P)
View Specs
JDZX15-6R-CQ Indoor Single-phase Metal ArmouReddish  Brown Epoxy Resin Casting Voltage Transformer
6kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZX15-6R-CQ

Indoor Single-phase Metal ArmouReddish Brown Epoxy Resin Casting Voltage Transformer

JDZX15-6R-CQ Indoor Single-phase Metal ArmouReddish Brown Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 6kV, accuracy class 0.2 / 0.5. Design: insulation level 7.2/32/60kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy Class0.2 / 0.5
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JDZX15-6R2-CQ Indoor Single-phase Metal ArmouReddish  Brown Epoxy Resin Casting Voltage Transformer
6kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZX15-6R2-CQ

Indoor Single-phase Metal ArmouReddish Brown Epoxy Resin Casting Voltage Transformer

JDZX15-6R2-CQ Indoor Single-phase Metal ArmouReddish Brown Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 6kV, accuracy class 0.2 / 0.5. Design: insulation level 7.2/32/60kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy Class0.2 / 0.5
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JDZX16-10-6W Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX16-10-6W

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX16-10-6W Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, 3P, rated burden 30VA / 100VA / 180VA / 100VA / 800VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2, 0.5, 1.0, 3P
Insulation TypeDry Epoxy Resin
Rated Burden30VA / 100VA / 180VA / 100VA / 800VA
View Specs