Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.
225 models
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZU16-10-6W2 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2,0.5, rated burden 50VA / 100VA / 200VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZU51-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2,0.5, rated burden 40VA / 80VA / 150VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZU6-10-6R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2,0.5, rated burden 20VA / 40VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZU61-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2,0.5, rated burden 50VA / 100VA / 200VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
10kV Outdoor Silicone Rubber Voltage Transformer with 1 Fuse
Outdoor single-phase silicone rubber insulated voltage transformer for 10kV/6kV systems. Built-in one primary fuse for overcurrent protection. Rated insulation level 12/42/75kV and 7.2/32/60kV. Compliant with IEC 61869 and GB/T 20840 standards. Multiple accuracy class combinations: 0.2, 0.5, 1.0. Rated output up to 80VA, secondary thermal limiting output 500VA. UV resistant, anti-pollution, suitable for outdoor pole-mounted installation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZ9-10-6A Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2,0.5,1.0 /0.2/0.5, rated burden 20VA / 40VA / 60VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
10kV Outdoor Silicone Rubber Voltage Transformer with 2 Fuses
Outdoor single-phase silicone rubber insulated voltage transformer for 10kV/6kV systems. Built-in two primary fuses for dual overcurrent protection. Rated insulation level 12/42/75kV and 7.2/32/60kV. Compliant with IEC 61869 and GB/T 20840 standards. Multiple accuracy class combinations: 0.2, 0.5, 1.0. Rated output up to 80VA, secondary thermal limiting output 500VA. UV resistant, anti-pollution, suitable for outdoor pole-mounted installation.
Outdoor Single-phase Silicone Rubber Voltage Transformer 10kV 6kV
JDZW6-10 6 Outdoor Single-phase Silicone Rubber Voltage Transformer 10kV 6kV (JDZW6-10-6) is designed for metering and protection in power systems. Key ratings: primary voltage 10kV/6kV, accuracy class 0.2/0.5/1.0. Design: Silicone Rubber, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
Outdoor Single-phase Silicone Rubber Voltage Transformer 10kV 6kV with 1 Fuse
JDZW6-10 6AR1 Outdoor Single-phase Silicone Rubber Voltage Transformer 10kV 6kV with 1 Fuse (JDZW6-10-6AR1) is designed for metering and protection in power systems. Key ratings: primary voltage 10kV/6kV, accuracy class 0.2/0.5/1.0. Design: Silicone Rubber, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
Outdoor Single-phase Silicone Rubber Voltage Transformer 10kV 6kV with 2 Fuses
JDZW6-10 6AR2 Outdoor Single-phase Silicone Rubber Voltage Transformer 10kV 6kV with 2 Fuses (JDZW6-10-6AR2) is designed for metering and protection in power systems. Key ratings: primary voltage 10kV/6kV, accuracy class 0.2/0.5/1.0. Design: Silicone Rubber, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
Outdoor Single-phase Silicone Rubber Voltage Transformer 10kV 6kV with 2 Fuses
JDZW6-10 6R2 Outdoor Single-phase Silicone Rubber Voltage Transformer 10kV 6kV with 2 Fuses (JDZW6-10-6R2) is designed for metering and protection in power systems. Key ratings: primary voltage 10kV/6kV, accuracy class 0.2/0.5/1.0. Design: Silicone Rubber, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZX10-10-6A Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV/6kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P), rated burden 10VA / 30VA / 50VA / 50VA. Design: insulation level 7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.