KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsVT / PT
Product category

Voltage Transformer (VT) / Potential Transformer (PT)

Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.

225 models

Representative Models

JDZ9-35D2 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZ9-35D2

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZ9-35D2 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, rated burden 150VA / 300VA / 600VA / 1500VA. Design: insulation level 40.5/95/200kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2, 0.5, 1.0
Insulation TypeDry Epoxy Resin
Rated Burden150VA / 300VA / 600VA / 1500VA
View Specs
JSZV18-6AR Indoor Three-phase Epoxy Resin Casting Voltage Transformer
6kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JSZV18-6AR

Indoor Three-phase Epoxy Resin Casting Voltage Transformer

JSZV18-6AR Indoor Three-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 6kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JDZW3-35R1 Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV with 1 Fuse
35kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZW3-35R1

Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 35kV with 1 Fuse

Outdoor single-phase epoxy resin casting voltage transformer with 1 primary fuse, 35kV rated, for voltage measurement and protection in power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, good weather resistance, anti-UV, suitable for outdoor installation. Accuracy classes: 0.2, 0.5, 1.0. Customizable ratios and specifications.

Accuracy Class0.2/0.5/1.0
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
JDZX15-27.5-CQ Indoor Single-phase Metal Armoured Epoxy Resin Casting Voltage Transformer
27.5kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz / 60Hz

JDZX15-27.5-CQ

Indoor Single-phase Metal Armoured Epoxy Resin Casting Voltage Transformer

Indoor single-phase metal armoured epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 31.5/95/200kV, applicable for 50Hz/60Hz power systems, aluminum shell full grounding design, net weight 75kg.

Accuracy Class0.2、0.5
Insulation TypeDry Epoxy Resin
Rated Burden20VA(0.2),50VA(0.5),100VA(1.0),200VA(3P)
View Specs
JDZW2-24 Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 24kV ANSI/IEEE C57.13
24kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZW2-24

Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 24kV ANSI/IEEE C57.13

Outdoor single-phase epoxy resin casting voltage transformer, 24kV rated, designed according to ANSI/IEEE C57.13 standard, for voltage measurement and protection in power distribution systems. Epoxy resin construction, good weather resistance, anti-UV, suitable for outdoor installation. Accuracy classes: 0.6W, 0.6X, 0.6Y, 1.2Z. Customizable ratios and specifications.

Accuracy Class0.6W/0.6X/0.6Y/1.2Z
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceANSI/IEEE C57.13
View Specs
JDZX15-20-CQ Indoor Single-phase Metal Armoured Epoxy Resin Casting Voltage Transformer
20kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz / 60Hz

JDZX15-20-CQ

Indoor Single-phase Metal Armoured Epoxy Resin Casting Voltage Transformer

Indoor single-phase metal armoured epoxy resin casting voltage transformer, compliant with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 24/65/125kV, applicable for 50Hz/60Hz power systems, shell full-grounding design, net weight 51kg.

Accuracy Class0.2/3P(6P)、0.5/3P(6P)、1.0/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden20VA(0.2),75VA(0.5),120VA(1.0),100VA(3P)
View Specs
JDZ9-20-15A Indoor Single-phase Epoxy Resin Casting Voltage Transformer
20kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZ9-20-15A

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZ9-20-15A Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2,0.5,1.0, rated burden 50VA / 100VA / 200VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2,0.5,1.0
Insulation TypeDry Epoxy Resin
Rated Burden50VA / 100VA / 200VA
View Specs
JDZU6-20-15R Indoor Single-phase Epoxy Resin Casting Voltage Transformer
20kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZU6-20-15R

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZU6-20-15R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2,0.5,1.0, rated burden 30VA / 60VA / 150VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2,0.5,1.0
Insulation TypeDry Epoxy Resin
Rated Burden30VA / 60VA / 150VA
View Specs
JDZXF15-15R-CQ Indoor Single-phase Fuse-built-in Metal Armoured Insulation-separated Voltage Transformer
15kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZXF15-15R-CQ

Indoor Single-phase Fuse-built-in Metal Armoured Insulation-separated Voltage Transformer

JDZXF15-15R-CQ Indoor Single-phase Fuse-built-in Metal Armoured Insulation-separated Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 15kV, accuracy class 0.2/0.5/1.0, rated burden 40VA(0.2)、100VA(0.5)、200VA(1.0). Design: insulation level 18/55/105kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy Class0.2/0.5/1.0
Insulation TypeDry Epoxy Resin
Rated Burden40VA(0.2)、100VA(0.5)、200VA(1.0)
View Specs
JDZF11-20-15 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
20kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZF11-20-15

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZF11-20-15 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, rated burden 20VA / 30VA / 60VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2, 0.5
Insulation TypeDry Epoxy Resin
Rated Burden20VA / 30VA / 60VA
View Specs
JDZW-20 15R1 Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 20kV 15kV with 1 Fuse
20kV/15kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZW-20-15R1

Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 20kV 15kV with 1 Fuse

Outdoor single-phase epoxy resin casting voltage transformer with 1 primary fuse, 20kV/15kV rated, for voltage measurement and protection in power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, good weather resistance, anti-UV, suitable for outdoor installation. Accuracy classes: 0.2, 0.5, 1.0. Customizable ratios and specifications.

Accuracy Class0.2/0.5/1.0
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
JDZF9-20-15 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
20kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZF9-20-15

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZF9-20-15 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, rated burden 30VA / 40VA / 50VA. Design: insulation level 24/65/125kV,18/55/105kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2, 0.5, 1.0
Insulation TypeDry Epoxy Resin
Rated Burden30VA / 40VA / 50VA
View Specs
← Prev1…34567…19Next →
Browse full catalogue