Transformator arus resin epoksi cor satu fasa dalam ruangan yang sesuai dengan standar GB/T20840.1/2 dan IEC61869-1/2; tingkat isolasi nominal 40,5/95/185kV, frekuensi nominal 50/60Hz, arus sekunder nominal 5A atau 1A. Arus primer opsional mencakup 20–3150A; keluaran nominal kelas akurasi: 10VA(0,2S/0,5S), 30VA(0,5), 30VA(5P10), 20VA(5P15), 15VA(5P20); arus termal jangka pendek berkisar 4–31,5kA, arus tahan dinamis nominal berkisar 10–130kA; berat produk: 84kg; suhu operasi lingkungan -5°C hingga +40°C.
CT cetakan epoksi 35kV dalam ruangan untuk switchgear MV; mendukung primer 20-3150A, sekunder 5A/1A, berbagai kelas akurasi.
| Parameter | Spesifikasi | Verifikasi |
|---|---|---|
| Jenis Produk | Transformator Arus | [Atas Permintaan] |
| Kode Model | LZZBJ9-35-Q | Penandaan pabrik |
| Tegangan Primer | 35kV | Uji tegangan nominal (IEC 61869-1/3) |
| Arus Sekunder | 5A/1A | Pemeriksaan rasio pada frekuensi nominal |
| Kelas Akurasi | [On Request] | Uji akurasi (IEC 61869-2 / IEEE C57.13) |
| Beban Nominal | [On Request] | Uji beban pada VA nominal |
| Jenis Isolasi | Dry Epoxy Resin | Uji dielektrik sesuai standar |
| Tingkat Isolasi (BIL) | 40.5/95/185kV | Ketahanan frekuensi daya & impuls petir |
| Standar | [On Request] | Tersertifikasi sesuai standar yang tercantum |
| Frekuensi | 50/60Hz | Sesuai IEC 61869-1 |
| Lingkungan | Ambient: -5℃~+40℃ | Sesuai batas lembar data |
Ideal Untuk
Tidak Direkomendasikan Untuk
Untuk CT: Hubungkan primer secara seri dengan saluran. Terminal sekunder: 1S1/1S2 untuk pengukuran, 2S1-2S2 untuk proteksi. Jangan pernah membuka rangkaian sekunder CT saat bertegangan - tegangan berbahaya. Hubungkan belitan sekunder ke tanah pada satu titik. Ikuti penandaan terminal IEC 61869-2. ⚠️ Safety: Follow the nameplate terminal diagram and ground the secondary winding at one point.
Sesuai dengan: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
T: Apa tingkat isolasi CT ini?
J: Tingkat isolasi adalah sistem 40,5kV; tahan tegangan frekuensi daya 95kV; tahan impuls petir 185kV puncak.
T: Apakah CT ini dapat digunakan untuk pengukuran dan proteksi sekaligus?
J: Ya, CT ini menawarkan kelas akurasi 0,2S/0,5S untuk pengukuran dan 5P10/5P15/5P20 untuk proteksi.
T: Berapa arus primer maksimum?
J: Arus primer opsional mencakup hingga 3150A.
Bidang yang hilang ditandai [Atas Permintaan] — tidak pernah direkayasa. Baris verifikasi M2/M5/M6 mengikuti konvensi IEC 61869 / IEEE C57.13.
| Rated primary current I1n (A) | Accuracy classCombined | Accuracy class & rated output (VA) COSΦ=0.8 0.2 (S)/0.5S | Accuracy class & rated output (VA) COSΦ=0.8 0.5 | Accuracy class & rated output (VA) COSΦ=0.8 5P10 | Accuracy class & rated output (VA) COSΦ=0.8 5P15 | Accuracy class & rated output (VA) COSΦ=0.8 5P20 | Short-time thermal current I1th (kA/S) Short-time thermal current kA | Short-time thermal current I1th (kA/S) Short-time thermal current s | Rated dynamic current Idyn (kA) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|---|
| 20 | 0.2(S)/0.5(S) | 10 | 30 | 30 | 20 | 15 | 4 | 1 | 10 | 84 |
| 30-40 | 0.2(S)/5P | 10 | 30 | 30 | 20 | 15 | 4 | 2 | 10 | 84 |
| 50 | 0.2(S)/5P | 10 | 30 | 30 | 20 | 15 | 12 | 1 | 30 | 84 |
| 75 | 0.5(S)/5P | 10 | 30 | 30 | 20 | 15 | 16 | 1 | 40 | 84 |
| 100-150 | 0.2(S)/5P | 10 | 30 | 30 | 20 | 15 | 25 | 1 | 63 | 84 |
| 200-300 | 0.2(S)/5P | 10 | 30 | 30 | 20 | 15 | 31.5 | 1 | 80 | 84 |
| 400-600 | 0.5(S)/5P | 10 | 30 | 30 | 20 | 15 | 31.5 | 2 | 80 | 84 |
| 800-1600 | 0.5(S)/5P | 10 | 30 | 30 | 20 | 15 | 31.5 | 4 | 130 | 84 |
| 2000-3150 | 0.5(S)/5P | 10 | 30 | 30 | 20 | 15 | — | — | — | 84 |

Gambar dimensi & garis besar LZZBJ9-35-Q — klik gambar untuk memperbesar / melihat asli.
LZZBJ9-35(Q) is the 35 kV model with a 1600 A ceiling, 84 kg, and outputs of 10 VA to 30 VA across five cores. The (Q) suffix marks the reinforced cast body used for this ratio range, which is why it is heavier than the 35A despite covering a shorter current span.
Accuracy pairings run from 0.2(S)/0.5(S) at 20 A through 0.2(S)/5P and 0.5(S)/5P at the higher ratios, with 10 VA, 30 VA, 30 VA, 20 VA and 15 VA on the five cores. Short-time thermal current is 4 kA/1 s at 20 A rising to 31.5 kA/4 s at 800–1600 A, with a 10–130 kA dynamic range.
Use the Q frame where the system current stays within 1600 A but the protection cores need 30 VA or the metering core needs the 0.2(S) class at small ratios. Above 1600 A the 35G or 35D1 frames take over.
Keluarga produk sama, rating berbeda — bandingkan sebelum menentukan spesifikasi.
Transformator Arus Resin Epoksi Cor Satu Fasa Dalam Ruangan, 10kV
Transformator arus resin epoksi cor satu fasa dalam ruangan sesuai standar GB/T20840.1/2 dan IEC61869-1/2. Tingkat isolasi: 12/42/75kV, frekuensi 50/60Hz, arus sekunder 5A atau 1A. Rentang arus primer opsional yang luas dari 20A hingga 6000A, berbagai kombinasi kelas akurasi untuk pengukuran dan proteksi, tap belitan sekunder yang dapat diubah (multi-rasio) tersedia untuk beberapa versi. Arus tahan termal waktu singkat dan arus tahan dinamis disesuaikan untuk setiap spesifikasi, cocok untuk pengukuran dan proteksi relai pada kabinet switchgear tegangan menengah. Suhu operasi lingkungan: -5°C hingga +40°C, tersedia berbagai pilihan dimensi dan berat untuk sub-versi yang berbeda.
Transformator Arus Resin Epoksi Cor Dalam Ruangan 10kV untuk Kabinet KYN28
Transformator arus resin epoksi cor dalam ruangan 12kV untuk switchgear KYN28. Belitan ganda mendukung pengukuran presisi tinggi 0,2S dan proteksi 5P20/5P30. Tingkat isolasi nominal 12/42/75kV, 50/60Hz, arus sekunder 5A atau 1A. Sesuai dengan standar IEC 61869 dan GB/T 20840. Proses cetakan epoksi vakum, pelepasan parsial rendah, tahan kelembapan dan semprotan garam. Tersedia dalam ukuran struktural A/B/C, rasio dan kelas akurasi dapat disesuaikan.
Transformator Arus Resin Epoksi Cor Satu Fasa Dalam Ruangan
Transformator arus resin epoksi cor satu fasa dalam ruangan yang sesuai dengan standar GB/T20840.1/2 dan IEC61869-1/2, tingkat isolasi 12/42/75kV, frekuensi nominal 50/60Hz, arus nominal sekunder 5A atau 1A. Rentang arus primer opsional: 20-150A, 200A, 300A, 400A, 500A, 600-800A, 1000-1250A; kombinasi akurasi meliputi 0,2S/0,5S/510P10, 0,2S/510P10/510P10, 0,5S/510P10/510P10; keluaran nominal: 10VA untuk 0,2S, 10VA untuk 0,5S, 15VA untuk 510P10; arus tahan termal waktu singkat 16–64 kAS, arus tahan dinamis nominal 40–160 kA, berat bersih 28kg, suhu operasi lingkungan -5°C hingga +40°C.