LZZBJ9-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-35-Q) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.
35 kV reinforced-body epoxy-cast CT, 20–1600 A, five cores at 10–30 VA, 84 kg.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LZZBJ9-35-Q | Factory nameplate marking |
| Primary Voltage | 35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A/1A | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | 40.5/95/185kV | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Ambient: -5℃~+40℃ | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary in series with the line. Secondary terminals: 1S1/1S2 for metering, 2S1-2S2 for protection. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What does the (Q) in the model code indicate?
A: The reinforced cast body used for this 1600 A frame, which is what accounts for its 84 kg mass.
Q: Can it be used above 1600 A?
A: No. The published ratio range ends at 1600 A; higher currents require the 35G or 35D1 frames.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current I1n (A) | Accuracy classCombined | Accuracy class & rated output (VA) COSΦ=0.8 0.2 (S)/0.5S | Accuracy class & rated output (VA) COSΦ=0.8 0.5 | Accuracy class & rated output (VA) COSΦ=0.8 5P10 | Accuracy class & rated output (VA) COSΦ=0.8 5P15 | Accuracy class & rated output (VA) COSΦ=0.8 5P20 | Short-time thermal current I1th (kA/S) Short-time thermal current kA | Short-time thermal current I1th (kA/S) Short-time thermal current s | Rated dynamic current Idyn (kA) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|---|
| 20 | 0.2(S)/0.5(S) | 10 | 30 | 30 | 20 | 15 | 4 | 1 | 10 | 84 |
| 30-40 | 0.2(S)/5P | 10 | 30 | 30 | 20 | 15 | 4 | 2 | 10 | 84 |
| 50 | 0.2(S)/5P | 10 | 30 | 30 | 20 | 15 | 12 | 1 | 30 | 84 |
| 75 | 0.5(S)/5P | 10 | 30 | 30 | 20 | 15 | 16 | 1 | 40 | 84 |
| 100-150 | 0.2(S)/5P | 10 | 30 | 30 | 20 | 15 | 25 | 1 | 63 | 84 |
| 200-300 | 0.2(S)/5P | 10 | 30 | 30 | 20 | 15 | 31.5 | 1 | 80 | 84 |
| 400-600 | 0.5(S)/5P | 10 | 30 | 30 | 20 | 15 | 31.5 | 2 | 80 | 84 |
| 800-1600 | 0.5(S)/5P | 10 | 30 | 30 | 20 | 15 | 31.5 | 4 | 130 | 84 |
| 2000-3150 | 0.5(S)/5P | 10 | 30 | 30 | 20 | 15 | — | — | — | 84 |
Dimension & outline drawing of LZZBJ9-35-Q — click image to zoom / view original.
LZZBJ9-35(Q) is the 35 kV model with a 1600 A ceiling, 84 kg, and outputs of 10 VA to 30 VA across five cores. The (Q) suffix marks the reinforced cast body used for this ratio range, which is why it is heavier than the 35A despite covering a shorter current span.
Accuracy pairings run from 0.2(S)/0.5(S) at 20 A through 0.2(S)/5P and 0.5(S)/5P at the higher ratios, with 10 VA, 30 VA, 30 VA, 20 VA and 15 VA on the five cores. Short-time thermal current is 4 kA/1 s at 20 A rising to 31.5 kA/4 s at 800–1600 A, with a 10–130 kA dynamic range.
Use the Q frame where the system current stays within 1600 A but the protection cores need 30 VA or the metering core needs the 0.2(S) class at small ratios. Above 1600 A the 35G or 35D1 frames take over.
Same product family, different ratings — compare before you specify.
Indoor Single-phase Epoxy Resin Casting Current Transformer,10kV
LZZBJ9-10 Indoor Single-phase Epoxy Resin Casting Current Transformer,10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
10kV Indoor Epoxy Cast Current Transformer for KYN28 Cabinet
LZZBJ9-10GWA,B,C 10kV Indoor Epoxy Cast Current Transformer for KYN28 Cabinet (LZZBJ9-10GWA-B-C) is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A or 1A, accuracy class 0.2S, 0.5, 5P20, 5P30. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869, GB/T 20840.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZBJ9-12/135b/4s Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-12-135b-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A/1A. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.