中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLZZBJ9-35-Q
LZZBJ9-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer
35kVLZZBJ9-35-Q
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 35kV
Secondary Metering (1S1 - 1S2):5A/1A ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LZZBJ9-35-Q

LZZBJ9-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZBJ9-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-35-Q) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.

Key Engineering Advantages

  • 35kV indoor epoxy cast current transformer
  • wide primary current range
  • excellent thermal and dynamic resistance
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LZZBJ9-35-Q

Electrical Parameters

Primary Rated Voltage (Un):35kV
Secondary Winding Currents:5A/1A
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Insulation Level (BIL):40.5/95/185kV
Environmental Class:Ambient: -5℃~+40℃
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

35 kV reinforced-body epoxy-cast CT, 20–1600 A, five cores at 10–30 VA, 84 kg.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeLZZBJ9-35-QFactory nameplate marking
Primary Voltage35kVRated voltage test (IEC 61869-1/3)
Secondary Current5A/1ARatio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)40.5/95/185kVPower-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50/60HzPer IEC 61869-1
EnvironmentAmbient: -5℃~+40℃Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor medium voltage switchgear panels
  • Metering and protection applications up to 35kV
  • Revenue metering with 0.2S/0.5S accuracy
  • Systems requiring high short-circuit withstand (up to 31.5kA/3s)

Not Recommended For

  • Outdoor installations without additional enclosure
  • Gas-insulated switchgear (GIS) applications
  • DC systems or non-standard frequencies
  • High-altitude installations above 1000m without derating

Topology & Wiring

Connect primary in series with the line. Secondary terminals: 1S1/1S2 for metering, 2S1-2S2 for protection. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What does the (Q) in the model code indicate?

A: The reinforced cast body used for this 1600 A frame, which is what accounts for its 84 kg mass.

Q: Can it be used above 1600 A?

A: No. The published ratio range ends at 1600 A; higher currents require the 35G or 35D1 frames.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LZZBJ9-35-Q
11 cols · 9 rows

LZZBJ9-35 (Q) LZZQB8-35 (Q) Current Transformer — Technical Data

Rated primary current I1n (A)Accuracy classCombinedAccuracy class & rated output (VA) COSΦ=0.8 0.2 (S)/0.5SAccuracy class & rated output (VA) COSΦ=0.8 0.5Accuracy class & rated output (VA) COSΦ=0.8 5P10Accuracy class & rated output (VA) COSΦ=0.8 5P15Accuracy class & rated output (VA) COSΦ=0.8 5P20Short-time thermal current I1th (kA/S) Short-time thermal current kAShort-time thermal current I1th (kA/S) Short-time thermal current sRated dynamic current Idyn (kA)Weight (kg)
200.2(S)/0.5(S)1030302015411084
30-400.2(S)/5P1030302015421084
500.2(S)/5P10303020151213084
750.5(S)/5P10303020151614084
100-1500.2(S)/5P10303020152516384
200-3000.2(S)/5P103030201531.518084
400-6000.5(S)/5P103030201531.528084
800-16000.5(S)/5P103030201531.5413084
2000-31500.5(S)/5P1030302015———84
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LZZBJ9-35-Q — click image to zoom / view original.

Product Overview

About This Product

LZZBJ9-35-Q

LZZBJ9-35(Q) is the 35 kV model with a 1600 A ceiling, 84 kg, and outputs of 10 VA to 30 VA across five cores. The (Q) suffix marks the reinforced cast body used for this ratio range, which is why it is heavier than the 35A despite covering a shorter current span.

Accuracy pairings run from 0.2(S)/0.5(S) at 20 A through 0.2(S)/5P and 0.5(S)/5P at the higher ratios, with 10 VA, 30 VA, 30 VA, 20 VA and 15 VA on the five cores. Short-time thermal current is 4 kA/1 s at 20 A rising to 31.5 kA/4 s at 800–1600 A, with a 10–130 kA dynamic range.

Use the Q frame where the system current stays within 1600 A but the protection cores need 30 VA or the metering core needs the 0.2(S) class at small ratios. Above 1600 A the 35G or 35D1 frames take over.

Other Models in This Series

Same product family, different ratings — compare before you specify.

LZZBJ9-10 Indoor Single-phase Epoxy Resin Casting Current Transformer,10kV
10kV
Current Transformer50/60Hz

LZZBJ9-10

Indoor Single-phase Epoxy Resin Casting Current Transformer,10kV

LZZBJ9-10 Indoor Single-phase Epoxy Resin Casting Current Transformer,10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.

Accuracy Class0.2/0.5/1.0/5P10/10P10/10P15
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
LZZBJ9-10GWA,B,C 10kV Indoor Epoxy Cast Current Transformer for KYN28 Cabinet
10kV
Current Transformer50/60Hz

LZZBJ9-10GWA-B-C

10kV Indoor Epoxy Cast Current Transformer for KYN28 Cabinet

LZZBJ9-10GWA,B,C 10kV Indoor Epoxy Cast Current Transformer for KYN28 Cabinet (LZZBJ9-10GWA-B-C) is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A or 1A, accuracy class 0.2S, 0.5, 5P20, 5P30. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869, GB/T 20840.

Accuracy Class0.2S, 0.5, 5P20, 5P30
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869
View Specs
LZZBJ9-12/135b/4s Indoor Single-phase Epoxy Resin Casting Current Transformer
12kV
Current Transformer50/60Hz

LZZBJ9-12-135b-4s

Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZBJ9-12/135b/4s Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-12-135b-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A/1A. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs