LZZBJ9-10GWA,B,C 10kV Indoor Epoxy Cast Current Transformer for KYN28 Cabinet (LZZBJ9-10GWA-B-C) is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A or 1A, accuracy class 0.2S, 0.5, 5P20, 5P30. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869, GB/T 20840.
KYN28 variants (A/B/C frames) of the 10 kV LZZBJ9, 50–3000 A, 0.2S/0.5/5P20, 10–20 VA depending on ratio.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 61869, GB/T 20840 |
| Model Code | LZZBJ9-10GWA-B-C | Factory nameplate marking |
| Primary Voltage | 10kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A or 1A | Ratio check at rated frequency |
| Accuracy Class | 0.2S, 0.5, 5P20, 5P30 | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | 12/42/75kV | Power-frequency & lightning impulse withstand |
| Standards | IEC 61869, GB/T 20840 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Indoor pillar-type epoxy resin cast | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary terminals P1/P2 in series with the line. Secondary terminals: 1S1-1S2 for metering winding, 2S1-2S2 for protection winding. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869 terminal markings.
Compliant with: IEC 61869, GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the difference between LZZBJ9-10GWA, GWB and GWC?
A: They are three mounting frames for KYN28 switchgear with the same electrical design; the letter changes the mechanical fit, not the ratings.
Q: What burden can the 5P20 core carry?
A: 10 VA up to about 300 A, 15 VA from 400 A and 20 VA from 1200 A upward.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current I1n (A) | Accuracy classCombined | Accuracy class-Rated output (VA) 0.2S | Accuracy class-Rated output (VA) 0.5 | Accuracy class-Rated output (VA) 5P20 | Accuracy class-Rated output (VA) 0.5S | Accuracy class-Rated output (VA) 5P30 | Accuracy class-Rated output (VA) 0.5S | Model |
|---|---|---|---|---|---|---|---|---|
| 50E | 0.2S/0.5/5P20 | / | / | 10 | 10 | / | 10 | LZZBJ9-10GWA |
| 100S | 0.2S/0.5/5P20 | 10 | 10 | 10 | / | / | / | LZZBJ9-10GWA |
| 0.2S/0.5/5P20 | 10 | 10 | 10 | / | / | / | LZZBJ9-10GWB | |
| 200S | 0.2S/0.5/5P20 | 10 | 10 | 20 | / | / | / | LZZBJ9-10GWA |
| 0.2S/0.5/5P20 | 10 | 10 | 20 | / | / | / | LZZBJ9-10GWB | |
| 0.2S/0.5/5P20 | 10 | 10 | 20 | / | / | / | LZZBJ9-10GWC | |
| 300S | 0.2S/0.5/5P20 | 10 | 10 | 20 | / | / | / | LZZBJ9-10GWA |
| 0.2S/0.5/5P20 | 10 | 10 | 20 | / | / | / | LZZBJ9-10GWB | |
| 400S | 0.2S/0.5/5P20 | 15 | 15 | 20 | / | / | / | LZZBJ9-10GWC |
| 600S | 0.2S/0.5/5P20 | 15 | 15 | 20 | / | / | / | LZZBJ9-10GWA |
| 0.2S/0.5/5P20 | 15 | 15 | 20 | / | / | / | LZZBJ9-10GWB | |
| 1000-2500S | 0.2S/0.5/5P20 | 15 | 15 | 20 | / | / | / | LZZBJ9-10GWC |
| 0.2S/0.5/5P20 | 15 | 15 | 20 | / | / | / | LZZBJ9-10GWA | |
| 0.2S/0.5/5P20 | 15 | 15 | 20 | / | / | / | LZZBJ9-10GWB | |
| 1200-2500S | 0.2S/0.5/5P20 | 20 | 20 | 20 | / | / | / | LZZBJ9-10GWC |
| 0.2S/0.5/5P20 | 20 | 20 | 20 | / | / | / | LMZB3-10GWD | |
| 3000-4000S | 0.2S/0.5/5P20 | 20 | 20 | 20 | / | / | / | LMZB3-10GWE |
Dimension & outline drawing of LZZBJ9-10GWA-B-C — click image to zoom / view original.
LZZBJ9-10GWA, -10GWB and -10GWC are the KYN28 switchgear variants of the 10 kV LZZBJ9 family: three frame widths sharing one electrical design, so a panel builder can keep the same ratio and accuracy while matching the phase spacing of the cabinet. All three are indoor, single-phase, dry epoxy-cast units with a 5 A or 1 A secondary.
The published table runs from 50 A to 3000 A across the three frames, with accuracy 0.2S, 0.5 and 5P20. Rated output is 10 VA at the small and medium ratios and rises to 15 VA from 400 A, then 20 VA from 1200 A upward, so the same accuracy class can carry a heavier secondary burden on high-ratio units. Both metering and protection cores are available in a single cast body.
Selection between A, B and C is mechanical, not electrical: the three letters denote different mounting dimensions for KYN28 panels. When ordering, state the frame letter together with the ratio, accuracy class and burden; the electrical data is identical across the three, so a substitution between frames changes the fit, not the performance.
Same product family, different ratings — compare before you specify.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZBJ9-12/135b/4s Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-12-135b-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A/1A. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZBJ9-12/150b/2s(4s) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-12-150b-2s-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A/1A. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZBJ9-12/175b/2s(4s) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-12-175b-2s-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A/1A. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.