中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLZZBJ9-12-175b-2s-4s
LZZBJ9-12/175b/2s(4s) Indoor Single-phase Epoxy Resin Casting Current Transformer
12kVLZZBJ9-12-175b-2s-4s
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 12kV
Secondary Metering (1S1 - 1S2):5A/1A ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LZZBJ9-12-175b-2s-4s

LZZBJ9-12/175b/2s(4s) Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZBJ9-12/175b/2s(4s) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-12-175b-2s-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A/1A. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.

Key Engineering Advantages

  • 12kV indoor epoxy casting current transformer
  • multiple structural specifications & dual-ratio secondary tapping optional
  • excellent short-time thermal and dynamic stability
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LZZBJ9-12-175b-2s-4s

Electrical Parameters

Primary Rated Voltage (Un):12kV
Secondary Winding Currents:5A/1A
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Insulation Level (BIL):12/42/75kV
Environmental Class:Ambient: -5℃~+40℃
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

12 kV high-current epoxy-cast CT, 20–3150 A, 0.2/0.5/5P10 at 10 VA, 26 kg.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeLZZBJ9-12-175b-2s-4sFactory nameplate marking
Primary Voltage12kVRated voltage test (IEC 61869-1/3)
Secondary Current5A/1ARatio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)12/42/75kVPower-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50/60HzPer IEC 61869-1
EnvironmentAmbient: -5℃~+40℃Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor MV switchgear panels
  • Metering and protection applications
  • 10kV primary systems
  • 50/60Hz networks
  • Ambient temperatures -5°C to +40°C

Not Recommended For

  • Outdoor installations
  • Gas-insulated switchgear (GIS)
  • DC systems
  • High-voltage transmission (above 12kV)
  • High-humidity or corrosive environments

Topology & Wiring

connect secondary terminals 1S1/1S2 for main winding; if dual-ratio, use tapping for alternate ratio. Protection winding (if present) uses 2S1-2S2. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point only.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the maximum primary current of the LZZBJ9-12/175b/2s(4s)?

A: 3150 A, in the 2000–3150 A band of the datasheet.

Q: Is the accuracy class reduced at high ratios?

A: No. All ratio bands, up to 3150 A, are listed as 0.2/0.5/5P10 with 10 VA.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LZZBJ9-12-175b-2s-4s
6 cols · 7 rows

LZZBJ9-12/175b/2s (4s) Series Current Transformer — Technical Data

Rated primary current (A)Accuracy classCombinedAccuracy class & rated output (VA)Short-time thermal current (kA)Rated dynamic current (kA)Weight (kg)
20-1000.2/0.5/5P1010150/1s375/1s26
2000.2/0.5/5P1010150/1s375/1s26
300-4000.2/0.5/5P101031.58026
5000.2/0.5/5P101045112.526
600-12500.2/0.5/5P10106313026
15000.2/0.5/5P101010016026
2000-31500.2/0.5/5P101010016026
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LZZBJ9-12-175b-2s-4s — click image to zoom / view original.

Product Overview

About This Product

LZZBJ9-12-175b-2s-4s

LZZBJ9-12/175b/2s(4s) extends the 12 kV LZZBJ9 range up to 3150 A primary, which makes it the model for high-current incomers and busbar sections where the smaller 150b frame runs out of ratio. Two or four secondary cores are available, and the cast unit weighs 26 kg.

The datasheet is organised in seven ratio bands from 20–100 A to 2000–3150 A. Every band carries 0.2/0.5/5P10 accuracy with 10 VA, so the metering class does not have to be traded away as the primary current increases. Short-time thermal current follows the ratio: 150 times primary for 1 s in the lowest band, then 31.5 kA, 45 kA, 63 kA and 100 kA in the upper bands, with dynamic ratings from 80 kA to 160 kA.

Choose this model when the rated current is above roughly 1250 A but the panel still uses the standard 12 kV LZZBJ9 footprint. For lower currents the 150b frame is smaller and lighter; for four-core metering-plus-protection duty at very high current, confirm the secondary burden against the 10 VA rating of each core.

Other Models in This Series

Same product family, different ratings — compare before you specify.

LZZBJ9-12/185h/2s(4s) Indoor Single-phase Epoxy Resin Casting Current Transformer
12kV
Current Transformer50/60Hz

LZZBJ9-12-185h-2s-4s

Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZBJ9-12/185h/2s(4s) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-12-185h-2s-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A/1A. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
LZZBJ9-12/195b/4s Indoor Single-phase Epoxy Cast Current Transformer 12kV
0.5kV
Current Transformer50/60Hz

LZZBJ9-12-195b-4s

Indoor Single-phase Epoxy Cast Current Transformer 12kV

Indoor single-phase epoxy resin casting CT, compliant with GB/T20840.1/2 & IEC61869-1/2, insulation level 12/42/75kV, 50/60Hz, secondary current 5A/1A. Optional primary current ranges:20-200A、300A、400A、500-600A、800-1000A、1200-3150A; multiple accuracy combinations of metering and protection grades, matched thermal/dynamic withstand parameters for each range, net weight 62kg, operating temperature -5℃~+40℃.

Accuracy Class0.5/1.0/3.0
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
LZZBJ9-12/198b/4s Indoor Single-phase Epoxy Cast Current Transformer 12kV
12kV
Current Transformer50/60Hz

LZZBJ9-12-198b-4s

Indoor Single-phase Epoxy Cast Current Transformer 12kV

LZZBJ9-12/198b/4s Indoor Single-phase Epoxy Cast Current Transformer 12kV (LZZBJ9-12-198b-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, accuracy class 0.5/1.0/3.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.

Accuracy Class0.5/1.0/3.0
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs