LZZBJ9-12/135b/4s Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-12-135b-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A/1A. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.
12 kV four-core epoxy-cast CT, 20–1250 A, 0.2(S)/0.5(S)/5(10)P10 at 10/10/15 VA, 28 kg.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LZZBJ9-12-135b-4s | Factory nameplate marking |
| Primary Voltage | 12kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A/1A | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | 12/42/75kV | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Ambient: -5℃~+40℃ | Per datasheet limits |
Ideal For
Not Recommended For
Ensure secondary terminals 1S1/1S2 are connected to the measuring device, and protection winding 2S1-2S2 if applicable. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: How many secondary cores does the LZZBJ9-12/135b/4s have?
A: Four, which is what the 4s suffix denotes; metering and protection circuits can be separated without a second transformer.
Q: What is the short-time thermal current at 20–150 A?
A: 100 times the rated primary current for 1 s, with a dynamic rating of 250 times the primary current.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current I1n (A) | Accuracy classCombined | Accuracy class & rated output (VA) 0.2 (S) | Accuracy class & rated output (VA) 0.5 (S) | Accuracy class & rated output (VA) 5 (10)P10 | Short-time thermal current Ith (kA/S) | Rated dynamic current Idyn (kA) | Weight (kg) |
|---|---|---|---|---|---|---|---|
| 20-150 | 0.2(S)/0.5(S)/5(10)P10 0.2(S)/5(10)P10/5(10)P10 0.5(S)/5(10)P10/5(10)P10 | 10 | 10 | 15 | 100 I1n | 250 I1n | 28 |
| 200 | 0.2(S)/0.5(S)/5(10)P10 0.2(S)/5(10)P10/5(10)P10 0.5(S)/5(10)P10/5(10)P10 | 10 | 10 | 15 | 16 | 40 | 28 |
| 300 | 0.2(S)/0.5(S)/5(10)P10 0.2(S)/5(10)P10/5(10)P10 0.5(S)/5(10)P10/5(10)P10 | 10 | 10 | 15 | 24 | 60 | 28 |
| 400 | 0.2(S)/0.5(S)/5(10)P10 0.2(S)/5(10)P10/5(10)P10 0.5(S)/5(10)P10/5(10)P10 | 10 | 10 | 15 | 30 | 75 | 28 |
| 500 | 0.2(S)/0.5(S)/5(10)P10 0.2(S)/5(10)P10/5(10)P10 0.5(S)/5(10)P10/5(10)P10 | 10 | 10 | 15 | 40 | 100 | 28 |
| 600-800 | 0.2(S)/0.5(S)/5(10)P10 0.2(S)/5(10)P10/5(10)P10 0.5(S)/5(10)P10/5(10)P10 | 10 | 10 | 15 | 48 | 120 | 28 |
| 1000-1250 | 0.2(S)/0.5(S)/5(10)P10 0.2(S)/5(10)P10/5(10)P10 0.5(S)/5(10)P10/5(10)P10 | 10 | 10 | 15 | 64 | 160 | 28 |
Dimension & outline drawing of LZZBJ9-12-135b-4s — click image to zoom / view original.
LZZBJ9-12/135b/4s is a 12 kV indoor epoxy-cast current transformer supplied with four secondary cores, so a single unit can serve revenue metering, measurement and two protection zones without stacking separate transformers in the panel. The cast body weighs 28 kg and mounts in conventional medium-voltage switchgear.
Its datasheet runs from 20 A to 1250 A. Accuracy combinations are 0.2(S)/0.5(S)/5(10)P10 in several arrangements, with 10 VA on the metering cores and 15 VA on the protection core. At 20–150 A the short-time thermal current is expressed as 100 times the primary current with a 250-times dynamic rating; above that the absolute figures apply, from 16 kA/40 kA at 200 A up to 64 kA/160 kA at 1000–1250 A.
The four-core layout is the reason to choose this model over a two-core 12 kV unit: one primary bar through one window feeds four independent secondary circuits. Confirm the burden of each connected relay or meter against the VA of its core before ordering, and earth the secondary circuits at a single point.
Same product family, different ratings — compare before you specify.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZBJ9-12/150b/2s(4s) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-12-150b-2s-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A/1A. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZBJ9-12/175b/2s(4s) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-12-175b-2s-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A/1A. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZBJ9-12/185h/2s(4s) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-12-185h-2s-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A/1A. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.