中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLZZBJ9-12-135b-4s
LZZBJ9-12/135b/4s Indoor Single-phase Epoxy Resin Casting Current Transformer
12kVLZZBJ9-12-135b-4s
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 12kV
Secondary Metering (1S1 - 1S2):5A/1A ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LZZBJ9-12-135b-4s

LZZBJ9-12/135b/4s Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZBJ9-12/135b/4s Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-12-135b-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A/1A. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.

Key Engineering Advantages

  • 12kV epoxy casting current transformer
  • wide current coverage
  • reliable thermal and dynamic stability
  • weight 28kg
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LZZBJ9-12-135b-4s

Electrical Parameters

Primary Rated Voltage (Un):12kV
Secondary Winding Currents:5A/1A
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Insulation Level (BIL):12/42/75kV
Environmental Class:Ambient: -5℃~+40℃
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

12 kV four-core epoxy-cast CT, 20–1250 A, 0.2(S)/0.5(S)/5(10)P10 at 10/10/15 VA, 28 kg.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeLZZBJ9-12-135b-4sFactory nameplate marking
Primary Voltage12kVRated voltage test (IEC 61869-1/3)
Secondary Current5A/1ARatio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)12/42/75kVPower-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50/60HzPer IEC 61869-1
EnvironmentAmbient: -5℃~+40℃Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor medium voltage switchgear panels
  • 10kV power distribution systems
  • Metering and protection applications
  • Applications requiring 0.2S/0.5S accuracy classes

Not Recommended For

  • Outdoor installations
  • Gas-insulated switchgear (GIS)
  • High voltage transmission systems above 12kV
  • DC systems

Topology & Wiring

Ensure secondary terminals 1S1/1S2 are connected to the measuring device, and protection winding 2S1-2S2 if applicable. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: How many secondary cores does the LZZBJ9-12/135b/4s have?

A: Four, which is what the 4s suffix denotes; metering and protection circuits can be separated without a second transformer.

Q: What is the short-time thermal current at 20–150 A?

A: 100 times the rated primary current for 1 s, with a dynamic rating of 250 times the primary current.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LZZBJ9-12-135b-4s
8 cols · 7 rows

LZZBJ9-12/135b/4s Series Current Transformer

Rated primary current I1n (A)Accuracy classCombinedAccuracy class & rated output (VA) 0.2 (S)Accuracy class & rated output (VA) 0.5 (S)Accuracy class & rated output (VA) 5 (10)P10Short-time thermal current Ith (kA/S)Rated dynamic current Idyn (kA)Weight (kg)
20-1500.2(S)/0.5(S)/5(10)P10 0.2(S)/5(10)P10/5(10)P10 0.5(S)/5(10)P10/5(10)P10101015100 I1n250 I1n28
2000.2(S)/0.5(S)/5(10)P10 0.2(S)/5(10)P10/5(10)P10 0.5(S)/5(10)P10/5(10)P10101015164028
3000.2(S)/0.5(S)/5(10)P10 0.2(S)/5(10)P10/5(10)P10 0.5(S)/5(10)P10/5(10)P10101015246028
4000.2(S)/0.5(S)/5(10)P10 0.2(S)/5(10)P10/5(10)P10 0.5(S)/5(10)P10/5(10)P10101015307528
5000.2(S)/0.5(S)/5(10)P10 0.2(S)/5(10)P10/5(10)P10 0.5(S)/5(10)P10/5(10)P101010154010028
600-8000.2(S)/0.5(S)/5(10)P10 0.2(S)/5(10)P10/5(10)P10 0.5(S)/5(10)P10/5(10)P101010154812028
1000-12500.2(S)/0.5(S)/5(10)P10 0.2(S)/5(10)P10/5(10)P10 0.5(S)/5(10)P10/5(10)P101010156416028
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LZZBJ9-12-135b-4s — click image to zoom / view original.

Product Overview

About This Product

LZZBJ9-12-135b-4s

LZZBJ9-12/135b/4s is a 12 kV indoor epoxy-cast current transformer supplied with four secondary cores, so a single unit can serve revenue metering, measurement and two protection zones without stacking separate transformers in the panel. The cast body weighs 28 kg and mounts in conventional medium-voltage switchgear.

Its datasheet runs from 20 A to 1250 A. Accuracy combinations are 0.2(S)/0.5(S)/5(10)P10 in several arrangements, with 10 VA on the metering cores and 15 VA on the protection core. At 20–150 A the short-time thermal current is expressed as 100 times the primary current with a 250-times dynamic rating; above that the absolute figures apply, from 16 kA/40 kA at 200 A up to 64 kA/160 kA at 1000–1250 A.

The four-core layout is the reason to choose this model over a two-core 12 kV unit: one primary bar through one window feeds four independent secondary circuits. Confirm the burden of each connected relay or meter against the VA of its core before ordering, and earth the secondary circuits at a single point.

Other Models in This Series

Same product family, different ratings — compare before you specify.

LZZBJ9-12/150b/2s(4s) Indoor Single-phase Epoxy Resin Casting Current Transformer
12kV
Current Transformer50/60Hz

LZZBJ9-12-150b-2s-4s

Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZBJ9-12/150b/2s(4s) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-12-150b-2s-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A/1A. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
LZZBJ9-12/175b/2s(4s) Indoor Single-phase Epoxy Resin Casting Current Transformer
12kV
Current Transformer50/60Hz

LZZBJ9-12-175b-2s-4s

Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZBJ9-12/175b/2s(4s) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-12-175b-2s-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A/1A. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
LZZBJ9-12/185h/2s(4s) Indoor Single-phase Epoxy Resin Casting Current Transformer
12kV
Current Transformer50/60Hz

LZZBJ9-12-185h-2s-4s

Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZBJ9-12/185h/2s(4s) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-12-185h-2s-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A/1A. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs