LZZBJ9-10 Indoor Single-phase Epoxy Resin Casting Current Transformer,10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
10 kV indoor epoxy-cast current transformer, 50–3000 A primary in the A1 frame, 0.2/0.5/5P20 classes at 10/15/15 VA, 21 kg.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 61869 / GB/T 20840 |
| Model Code | LZZBJ9-10 | Factory nameplate marking |
| Primary Voltage | 10kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A/1A | Ratio check at rated frequency |
| Accuracy Class | 0.2/0.5/1.0/5P10/10P10/10P15 | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | 12/42/75kV | Power-frequency & lightning impulse withstand |
| Standards | IEC 61869 / GB/T 20840 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
secondary terminals 1S1/1S2 (protection winding 2S1-2S2 if present). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point only. Observe polarity markings (P1/P2, S1/S2) for correct phase relation. Use shorting links before disconnecting secondary wiring.
Compliant with: IEC 61869 / GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What primary current range does the LZZBJ9-10 cover?
A: The A1 frame covers 50 A to 3000 A, in the standard ratio steps listed in the datasheet, with a 5 A or 1 A secondary.
Q: How much does the LZZBJ9-10 weigh?
A: The complete single-phase unit weighs 21 kg.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Model | Rated current ratio (A) | Accuracy classCombined | Rated output (VA) | Rated Short-time thermal current (kA/s) | Rated dynamic current (kA) | Weight (kg) |
|---|---|---|---|---|---|---|
| LZZBJ9-10A1 | 50/5 | 0.2/0.5/5P20 | 10/15/15 | 8/1 | 20 | 21 |
| LZZBJ9-10A1 | 75/5 | 0.2/0.5/5P20 | 10/15/15 | 12/1 | 30 | 21 |
| LZZBJ9-10A1 | 100/5 | 0.2/0.5/5P20 | 10/15/15 | 16/1 | 40 | 21 |
| LZZBJ9-10A1 | 150/5 | 0.2/0.5/5P20 | 10/15/15 | 24/1 | 60 | 21 |
| LZZBJ9-10A1 | 200/5 | 0.2/0.5/5P20 | 10/15/15 | 32/1 | 80 | 21 |
| LZZBJ9-10A1 | 300/5 | 0.2/0.5/5P20 | 10/15/15 | 48/1 | 120 | 21 |
| LZZBJ9-10A1 | 400/5 | 0.2/0.5/5P20 | 10/15/15 | 63/1 | 160 | 21 |
| LZZBJ9-10A1 | 500/5 | 0.2/0.5/5P20 | 10/15/15 | 63/1 | 160 | 21 |
| LZZBJ9-10A1 | 600/5 | 0.2/0.5/5P20 | 10/15/15 | 63/1 | 160 | 21 |
| LZZBJ9-10A1 | 800/5 | 0.2/0.5/5P20 | 10/15/15 | 80/1 | 160 | 21 |
| LZZBJ9-10A1 | 1000/5 | 0.2/0.5/5P20 | 10/15/15 | 80/1 | 160 | 21 |
| LZZBJ9-10A1 | 1200/5 | 0.2/0.5/5P20 | 10/15/15 | 80/1 | 160 | 21 |
| LZZBJ9-10A1 | 1500/5 | 0.2/0.5/5P20 | 10/15/15 | 100/1 | 200 | 21 |
| LZZBJ9-10A1 | 2000/5 | 0.2/0.5/5P20 | 10/15/15 | 100/1 | 200 | 21 |
| LZZBJ9-10A1 | 3000/5 | 0.2/0.5/5P20 | 10/15/15 | 100/1 | 200 | 21 |
| LZZBJ9-10C1A | 20-150/1 | 0.2(S)/5P、0.5(S)/5P | 0.2S:10 / 0.5:10 / 10P10:15 / 10P15:10 | 100 I1n | 250 I1n | 16 |
| LZZBJ9-10C1A | 200-300/1 | 0.2(S)/5P、0.5(S)/5P | 0.2S:10 / 0.5:10 / 10P10:15 / 10P15:10 | 31.5 | 80 | 16 |
| LZZBJ9-10C1A | 400/1 | 0.2(S)/5P、0.5(S)/5P | 0.2S:10 / 0.5:10 / 10P10:15 / 10P15:10 | 45 | 112.5 | 16 |
| LZZBJ9-10C1A | 500-600/1 | 0.2(S)/5P、0.5(S)/5P | 0.2S:10 / 0.5:10 / 10P10:15 / 10P15:10 | 63 | 130 | 16 |
| LZZBJ9-10C1A | 800-1000/1 | 0.2(S)/5P、0.5(S)/5P | 0.2S:10 / 0.5:10 / 10P10:15 / 10P15:10 | 80 | 160 | 16 |
Dimension & outline drawing of LZZBJ9-10 — click image to zoom / view original.
LZZBJ9-10 is the 10 kV frame of the LZZBJ9 indoor epoxy-cast current transformer family. It is a single-phase pillar-type unit cast in dry epoxy resin, used in medium-voltage switchgear for metering and protection, and needs no oil handling or routine maintenance. The complete unit weighs 21 kg, which keeps it manageable for panel mounting without lifting gear.
The A1 frame in our datasheet covers 50 A to 3000 A primary current with a 5 A or 1 A secondary. Accuracy classes 0.2, 0.5 and 5P20 are offered with rated outputs of 10 VA, 15 VA and 15 VA respectively. Short-time thermal current rises from 8 kA/1s at the small ratios to 100 kA/1s at 1500 A and above, with corresponding dynamic ratings of 20 kA to 200 kA.
Because one frame spans two orders of magnitude of primary current, the 10 kV LZZBJ9-10 is normally specified by ratio rather than by frame: revenue metering takes the 0.2 class at 10 VA, feeder protection takes 5P20, and combined metering-plus-protection takes a two-core unit. Installation is indoor only; the secondary must be earthed at one point and never left open while the primary is energised.
Same product family, different ratings — compare before you specify.
10kV Indoor Epoxy Cast Current Transformer for KYN28 Cabinet
LZZBJ9-10GWA,B,C 10kV Indoor Epoxy Cast Current Transformer for KYN28 Cabinet (LZZBJ9-10GWA-B-C) is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A or 1A, accuracy class 0.2S, 0.5, 5P20, 5P30. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869, GB/T 20840.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZBJ9-12/135b/4s Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-12-135b-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A/1A. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZBJ9-12/150b/2s(4s) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-12-150b-2s-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A/1A. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.