KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLZZBJ9-10
LZZBJ9-10 Indoor Single-phase Epoxy Resin Casting Current Transformer,10kV
10kVLZZBJ9-10
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 10kV
Secondary Metering (1S1 - 1S2):5A/1A (0.2/0.5/1.0/5P10/10P10/10P15)
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LZZBJ9-10

LZZBJ9-10 Indoor Single-phase Epoxy Resin Casting Current Transformer,10kV

LZZBJ9-10 Indoor Single-phase Epoxy Resin Casting Current Transformer,10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.

Key Engineering Advantages

  • 10kV indoor epoxy cast CT
  • wide current range
  • tap-change optional
  • for metering and protection
  • weight 16kg (1A) / 19kg (5A)
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LZZBJ9-10

Electrical Parameters

Primary Rated Voltage (Un):10kV
Secondary Winding Currents:5A/1A
Metering & Protection Class:0.2/0.5/1.0/5P10/10P10/10P15
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Insulation Level (BIL):12/42/75kV
Standards Conformance:IEC 61869 / GB/T 20840
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

10 kV indoor epoxy-cast current transformer, 50–3000 A primary in the A1 frame, 0.2/0.5/5P20 classes at 10/15/15 VA, 21 kg.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent TransformerIEC 61869 / GB/T 20840
Model CodeLZZBJ9-10Factory nameplate marking
Primary Voltage10kVRated voltage test (IEC 61869-1/3)
Secondary Current5A/1ARatio check at rated frequency
Accuracy Class0.2/0.5/1.0/5P10/10P10/10P15Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)12/42/75kVPower-frequency & lightning impulse withstand
StandardsIEC 61869 / GB/T 20840Certified to listed standards
Frequency50/60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor MV switchgear panels (e.g., RMU, GIS) up to 12kV
  • Revenue metering with accuracy class 0.2/0.5
  • Protection schemes requiring class 1.0 or 5P/10P (if specified)
  • Retrofit in existing 10kV indoor installations

Not Recommended For

  • Outdoor substations (non-weatherproof, indoor only)
  • Systems above 12kV (e.g., 24kV, 36kV)
  • DC applications (AC only)
  • High-altitude installations above 1000m (unless derated)

Topology & Wiring

secondary terminals 1S1/1S2 (protection winding 2S1-2S2 if present). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point only. Observe polarity markings (P1/P2, S1/S2) for correct phase relation. Use shorting links before disconnecting secondary wiring.

Standards & Compliance

Compliant with: IEC 61869 / GB/T 20840

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What primary current range does the LZZBJ9-10 cover?

A: The A1 frame covers 50 A to 3000 A, in the standard ratio steps listed in the datasheet, with a 5 A or 1 A secondary.

Q: How much does the LZZBJ9-10 weigh?

A: The complete single-phase unit weighs 21 kg.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LZZBJ9-10
7 cols · 20 rows

LZZBJ9-10 Series Current Transformer

ModelRated current ratio (A)Accuracy classCombinedRated output (VA)Rated Short-time thermal current (kA/s)Rated dynamic current (kA)Weight (kg)
LZZBJ9-10A150/50.2/0.5/5P2010/15/158/12021
LZZBJ9-10A175/50.2/0.5/5P2010/15/1512/13021
LZZBJ9-10A1100/50.2/0.5/5P2010/15/1516/14021
LZZBJ9-10A1150/50.2/0.5/5P2010/15/1524/16021
LZZBJ9-10A1200/50.2/0.5/5P2010/15/1532/18021
LZZBJ9-10A1300/50.2/0.5/5P2010/15/1548/112021
LZZBJ9-10A1400/50.2/0.5/5P2010/15/1563/116021
LZZBJ9-10A1500/50.2/0.5/5P2010/15/1563/116021
LZZBJ9-10A1600/50.2/0.5/5P2010/15/1563/116021
LZZBJ9-10A1800/50.2/0.5/5P2010/15/1580/116021
LZZBJ9-10A11000/50.2/0.5/5P2010/15/1580/116021
LZZBJ9-10A11200/50.2/0.5/5P2010/15/1580/116021
LZZBJ9-10A11500/50.2/0.5/5P2010/15/15100/120021
LZZBJ9-10A12000/50.2/0.5/5P2010/15/15100/120021
LZZBJ9-10A13000/50.2/0.5/5P2010/15/15100/120021
LZZBJ9-10C1A20-150/10.2(S)/5P、0.5(S)/5P0.2S:10 / 0.5:10 / 10P10:15 / 10P15:10100 I1n250 I1n16
LZZBJ9-10C1A200-300/10.2(S)/5P、0.5(S)/5P0.2S:10 / 0.5:10 / 10P10:15 / 10P15:1031.58016
LZZBJ9-10C1A400/10.2(S)/5P、0.5(S)/5P0.2S:10 / 0.5:10 / 10P10:15 / 10P15:1045112.516
LZZBJ9-10C1A500-600/10.2(S)/5P、0.5(S)/5P0.2S:10 / 0.5:10 / 10P10:15 / 10P15:106313016
LZZBJ9-10C1A800-1000/10.2(S)/5P、0.5(S)/5P0.2S:10 / 0.5:10 / 10P10:15 / 10P15:108016016
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LZZBJ9-10 — click image to zoom / view original.

Product Overview

About This Product

LZZBJ9-10

LZZBJ9-10 is the 10 kV frame of the LZZBJ9 indoor epoxy-cast current transformer family. It is a single-phase pillar-type unit cast in dry epoxy resin, used in medium-voltage switchgear for metering and protection, and needs no oil handling or routine maintenance. The complete unit weighs 21 kg, which keeps it manageable for panel mounting without lifting gear.

The A1 frame in our datasheet covers 50 A to 3000 A primary current with a 5 A or 1 A secondary. Accuracy classes 0.2, 0.5 and 5P20 are offered with rated outputs of 10 VA, 15 VA and 15 VA respectively. Short-time thermal current rises from 8 kA/1s at the small ratios to 100 kA/1s at 1500 A and above, with corresponding dynamic ratings of 20 kA to 200 kA.

Because one frame spans two orders of magnitude of primary current, the 10 kV LZZBJ9-10 is normally specified by ratio rather than by frame: revenue metering takes the 0.2 class at 10 VA, feeder protection takes 5P20, and combined metering-plus-protection takes a two-core unit. Installation is indoor only; the secondary must be earthed at one point and never left open while the primary is energised.

Other Models in This Series

Same product family, different ratings — compare before you specify.

LZZBJ9-10GWA,B,C 10kV Indoor Epoxy Cast Current Transformer for KYN28 Cabinet
10kV
Current Transformer50/60Hz

LZZBJ9-10GWA-B-C

10kV Indoor Epoxy Cast Current Transformer for KYN28 Cabinet

LZZBJ9-10GWA,B,C 10kV Indoor Epoxy Cast Current Transformer for KYN28 Cabinet (LZZBJ9-10GWA-B-C) is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A or 1A, accuracy class 0.2S, 0.5, 5P20, 5P30. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869, GB/T 20840.

Accuracy Class0.2S, 0.5, 5P20, 5P30
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869
View Specs
LZZBJ9-12/135b/4s Indoor Single-phase Epoxy Resin Casting Current Transformer
12kV
Current Transformer50/60Hz

LZZBJ9-12-135b-4s

Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZBJ9-12/135b/4s Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-12-135b-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A/1A. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
LZZBJ9-12/150b/2s(4s) Indoor Single-phase Epoxy Resin Casting Current Transformer
12kV
Current Transformer50/60Hz

LZZBJ9-12-150b-2s-4s

Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZBJ9-12/150b/2s(4s) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-12-150b-2s-4s) is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A/1A. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs