Transformator arus dalam ruangan resin epoksi cor yang dirancang untuk switchgear berisolasi gas CGIS, dengan berbagai pilihan kelas akurasi, beban nominal, dan arus primer.
Transformator arus dalam ruangan resin epoksi cor untuk switchgear berisolasi gas CGIS, bernilai 20kV, tersedia dalam berbagai kelas akurasi dan beban.
| Parameter | Spesifikasi | Verifikasi |
|---|---|---|
| Jenis Produk | Transformator Arus | [Atas Permintaan] |
| Kode Model | CGIS1555 | Penandaan pabrik |
| Tegangan Primer | 20kV | Uji tegangan nominal (IEC 61869-1/3) |
| Arus Sekunder | [On Request] | Pemeriksaan rasio pada frekuensi nominal |
| Kelas Akurasi | 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P) | Uji akurasi (IEC 61869-2 / IEEE C57.13) |
| Beban Nominal | 30VA / 60VA / 100VA / 100VA | Uji beban pada VA nominal |
| Jenis Isolasi | Dry Epoxy Resin | Uji dielektrik sesuai standar |
| Tingkat Isolasi (BIL) | 24/65/125kV,18/55/105kV | Ketahanan frekuensi daya & impuls petir |
| Standar | [On Request] | Tersertifikasi sesuai standar yang tercantum |
| Frekuensi | 50Hz or 60Hz | Sesuai IEC 61869-1 |
| Lingkungan | [On Request] | Sesuai batas lembar data |
Ideal Untuk
Tidak Direkomendasikan Untuk
Untuk transformator arus, terminal sekunder adalah 1S1/1S2 untuk belitan utama dan 2S1/2S2 untuk belitan proteksi. Jangan pernah membuka rangkaian sekunder CT saat bertegangan - tegangan berbahaya. Tanahkan belitan sekunder pada satu titik. ⚠️ Safety: Follow the nameplate terminal diagram and ground the secondary winding at one point.
Sesuai dengan: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
T: Apa tingkat isolasi CT ini?
J: Tingkat isolasi adalah 24/65/125kV, artinya sistem 24kV, tahan tegangan frekuensi daya 65kV, tahan impuls petir 125kV puncak. Juga tersedia sebagai 18/55/105kV.
T: Apa saja kelas akurasi yang tersedia?
J: Kelas akurasi adalah 0,2/6P(3P), 0,5/6P(3P), dan 1,0/6P(3P), cocok untuk pengukuran dan proteksi.
T: Apa beban nominalnya?
J: Pilihan beban nominal adalah 30VA, 60VA, dan 100VA (dua belitan pada 100VA).
Bidang yang hilang ditandai [Atas Permintaan] — tidak pernah direkayasa. Baris verifikasi M2/M5/M6 mengikuti konvensi IEC 61869 / IEEE C57.13.
| Accuracy class | Rated output (VA) | 40 | 50 | 60 | 75 | 100 | 125 | 150 | 200 | 250 | 300 | 400 | 500 | 600 | 750 | 1000 | 1200 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.2FS10 | 2.5 | — | — | — | — | 85 | 60 | 50 | 35 | 30 | 30 | 30 | 30 | 30 | 35 | 35 | 35 |
| 5 | — | — | — | — | 130 | 90 | 70 | 50 | 40 | 35 | 30 | 30 | 30 | 35 | 35 | 35 | |
| 10 | — | — | — | — | 150 | 115 | 75 | 55 | 45 | 35 | 35 | 30 | 30 | 35 | 35 | 35 | |
| 15 | — | — | — | — | — | 160 | 100 | 70 | 55 | 45 | 40 | 35 | 35 | 35 | 35 | 35 | |
| 20 | — | — | — | — | — | — | 125 | 85 | 65 | 55 | 45 | 40 | 40 | 35 | 35 | 35 | |
| 25 | — | — | — | — | — | — | — | 150 | 105 | 75 | 60 | 50 | 45 | 45 | 40 | 35 | |
| 30 | — | — | — | — | — | — | — | — | 120 | 85 | 70 | 55 | 50 | 45 | 40 | 40 | |
| 0.5FS10 | 2.5 | — | 115 | 80 | 50 | 40 | 35 | 30 | 30 | 30 | 25 | 25 | 25 | 25 | 25 | 25 | 25 |
| 5 | — | — | 130 | 75 | 60 | 45 | 35 | 30 | 30 | 30 | 25 | 25 | 25 | 25 | 25 | 25 | |
| 10 | — | — | — | 120 | 90 | 70 | 50 | 40 | 35 | 30 | 25 | 25 | 25 | 25 | 25 | 25 | |
| 15 | — | — | — | — | 120 | 90 | 65 | 55 | 40 | 35 | 30 | 25 | 25 | 25 | 25 | 25 | |
| 20 | — | — | — | — | 155 | 115 | 80 | 65 | 55 | 50 | 40 | 35 | 30 | 25 | 25 | 25 | |
| 25 | — | — | — | — | — | 140 | 90 | 75 | 65 | 55 | 45 | 35 | 30 | 25 | 25 | 25 | |
| 30 | — | — | — | — | — | — | 105 | 85 | 70 | 65 | 50 | 40 | 35 | 30 | 25 | 25 | |
| 5P10 | 2.5 | 135 | 100 | 85 | 75 | 55 | 40 | 35 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 25 | 25 |
| 10P10 | 5 | — | 135 | 120 | 85 | 70 | 55 | 50 | 45 | 40 | 35 | 30 | 35 | 30 | 30 | 30 | 30 |
| 10 | — | — | — | 145 | 110 | 95 | 80 | 70 | 60 | 50 | 45 | 45 | 35 | 35 | 35 | — | |
| 15 | — | — | — | — | 155 | 130 | 110 | 90 | 80 | 80 | 65 | 60 | 50 | 45 | 45 | 45 | |
| 20 | — | — | — | — | — | 140 | 115 | 100 | 95 | 80 | 70 | 60 | 55 | 45 | 45 | 45 | |
| 25 | — | — | — | — | — | — | 140 | 120 | 115 | 95 | 80 | 70 | 60 | 55 | 55 | 55 | |
| 30 | — | — | — | — | — | — | — | — | 140 | 130 | 110 | 95 | 80 | 65 | 60 | 60 | |
| 5P20 | 2.5 | — | 145 | 125 | 90 | 75 | 65 | 60 | 50 | 50 | 50 | 45 | 40 | 40 | 35 | 35 | 35 |
| 10P20 | 5 | — | — | 145 | 115 | 95 | 90 | 75 | 70 | 65 | 55 | 50 | 50 | 50 | 45 | 40 | — |
| 10 | — | — | — | — | 160 | 125 | 110 | 105 | 85 | 75 | 70 | 65 | 60 | 55 | 50 | — | |
| 15 | — | — | — | — | — | — | 150 | 140 | 115 | 100 | 85 | 75 | 70 | 65 | 65 | 60 | |
| 20 | — | — | — | — | — | — | — | — | 145 | 125 | 115 | 90 | 80 | 80 | 80 | 75 | |
| 25 | — | — | — | — | — | — | — | — | — | — | 150 | 135 | 105 | 95 | 95 | 90 | |
| 30 | — | — | — | — | — | — | — | — | — | — | — | 155 | 120 | 105 | 100 | 95 | |
| 5P30 | 2.5 | — | — | — | — | 130 | 105 | 90 | 85 | 75 | 70 | 65 | 55 | 55 | 55 | 50 | 50 |
| 10P30 | 5 | — | — | — | — | — | 145 | 135 | 115 | 100 | 95 | 80 | 75 | 75 | 65 | 60 | 60 |
| 10 | — | — | — | — | — | — | — | 170 | 155 | 125 | 115 | 110 | 90 | 80 | 80 | 80 | |
| 15 | — | — | — | — | — | — | — | — | — | — | 115 | 140 | 115 | 100 | 100 | 95 | |
| 20 | — | — | — | — | — | — | — | — | — | — | — | — | 140 | 125 | 120 | 110 | |
| 25 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 145 | 130 |

Gambar dimensi & garis besar CGIS1555 — klik gambar untuk memperbesar / melihat asli.
Keluarga produk sama, rating berbeda — bandingkan sebelum menentukan spesifikasi.
LJZ-Φ75/110/125 10kV Transformator Arus Tiga Fasa Terintegrasi Luar Ruangan dengan Urutan Nol untuk Pemutus Sirkuit Tiang
Transformator arus urutan nol untuk sistem tegangan 35kV dan di bawahnya. Digunakan untuk proteksi gangguan tanah kabel pada sistem arus gangguan tanah kecil. Frekuensi nominal 50Hz atau 60Hz. Tersedia dalam ukuran diameter dalam Φ75, Φ110, Φ125. Isolasi primer dijamin oleh kabel, isolasi belitan sekunder diuji. Sesuai dengan standar IEC 61869 dan GB/T 20840. Model relai yang cocok DL-11/0,2, konstruksi resin epoksi cor.
LXK-Φ120TH Transformator Arus Urutan Nol Tipe Belah Inti untuk Proteksi Gangguan Tanah
Transformator arus urutan nol tahan air, model LXK-Φ120TH. Kinerja tahan air sangat baik untuk lingkungan dalam ruangan yang lembap. Nilai nominal hingga 35kV, 50/60Hz. Desain belah dengan cincin penyegel tahan air, pemasangan pada kabel bertegangan. Desain tropis TH, sesuai dengan standar IEC 61869. Digunakan untuk proteksi gangguan tanah pada kabel tiga fasa.
Transformator Arus untuk Switchgear Inflatable
Transformator arus profesional yang didedikasikan untuk switchgear inflatable CGIS dengan berbagai kelas akurasi dan rentang arus primer yang tersedia; panjang kabel sekunder dan tinggi produk bertumpuk mendukung konfigurasi yang disesuaikan.