KEMA 与 ISO 9001/14001 认证|出口 50+ 国家 (IEC 61869-3 / IEEE C57.13)
24/7 全球工程热线: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
首页产品AI 选型关于我们博客联系我们

国际认证与测试

通过 KEMA Labs(荷兰)、CESI 与 CNAS 国家高压测试机构认证

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

全球 B2B 高压互感器门户

PotentialTransformers.com 是一家国际 OEM 与 EPC 供应商,专精干式环氧树脂浇注互感器(0.5kV 至 35kV)——电压互感器(VT/PT)、电流互感器(CT)与组合互感器,服务电力公用事业、开关柜制造商与重工业。

100% 出厂局部放电试验

关注我们 & 社交渠道

FacebookLinkedInYouTubeInstagramTikTok

产品分类

  • 电压互感器
  • 电流互感器
  • 组合互感器

工程工具

  • AI 数据中心系列
  • AI 规格与选型工作室
  • CT 负担计算器
  • 7.2–12 kV 户内浇注树脂电压互感器与电流互感器:绝缘、局部放电与 0.2S 准确级
  • 0.66 kV 低压电流互感器:穿心式、开合式与 0.5 级真正保证的是什么
  • 高压法拉第实验室测试
  • 索取技术数据表

全球支持

  • 香港中西区上环干诺道中111号永安中心16楼1602室
  • 86 18852046268
  • sales@potentialtransformers.com
  • 区域中心:阿联酋迪拜 | 德国法兰克福 | 美国休斯顿

© 2026 PotentialTransformers.com. 版权所有。为全球高压电网而造。

符合 IEC 61869-3符合 IEEE C57.13KEMA 型式试验
首页产品电流互感器SDH-0.66
SDH-0.66 户内低压电流互感器 0.66kV
0.66kVSDH-0.66
绕组与原理拓扑内部接线示意图
Primary Winding:0.66kV
Secondary Winding:5A/1A (0.2/0.5/1.0)
Safety:Follow nameplate terminal diagram; ground secondary at one point
电流互感器 通过 IEC 61869-3 认证
型号编号:SDH-0.66

SDH-0.66 户内低压电流互感器 0.66kV

户内低压电流互感器,额定电压0.66kV,环氧树脂浇注式,用于低压配电系统的电流测量和保护。符合IEC 61869和GB/T 20840标准。电流比范围广,多种准确级可选。结构紧凑,安装方便,适用于开关柜和面板安装。变比和规格可定制。

核心工程优势

  • 低压电流互感器
  • 0.66kV
  • 环氧树脂
  • 多种变比
  • 结构紧凑
  • 可定制
工程数据

完整电气与机械规格

型号编号: SDH-0.66

电气参数

一次额定电压 (Un):0.66kV
二次绕组电流:5A/1A
计量与保护准确级:0.2/0.5/1.0
额定频率:50/60Hz

绝缘与耐受额定值

绝缘系统:干式环氧树脂浇注
标准符合性:IEC 61869 / GB/T 20840
局部放电水平:< 5 pC at 1.2 Un

推荐部署环境

GEO · 工程决策支持

全球工程概览

9 模块选型指南
缺失数据 = [On Request]

产品决策摘要

户内低压电流互感器,用于0.66kV系统的测量和保护;紧凑型环氧树脂设计,适用于开关柜和面板安装。

综合规格矩阵

参数规格验证标准
产品类型电流互感器IEC 61869 / GB/T 20840
型号代码SDH-0.66工厂铭牌标识
一次电压0.66kV额定电压试验 (IEC 61869-1/3)
二次电流5A/1A额定频率下的变比校验
准确级0.2/0.5/1.0准确度试验 (IEC 61869-2 / IEEE C57.13)
额定负荷[On Request]额定 VA 下负荷试验
绝缘类型干式环氧树脂浇注按标准进行的介电试验
绝缘水平 (BIL)[On Request]工频与雷电冲击耐受
标准IEC 61869 / GB/T 20840按所列标准认证
频率50/60Hz依据 IEC 61869-1
环境[On Request]按数据表限值

适用与不适用边界

理想适用于

  • 户内低压开关柜和配电盘
  • 0.66kV配电系统中的电流测量和保护
  • 空间紧凑的面板安装
  • 可定制电流比和准确级

不建议用于

  • 户外或高压应用
  • 高压(1kV以上)系统
  • 气体绝缘开关设备(GIS)或SF6环境
  • 需要高短路耐受能力的应用

拓扑与接线

对于CT:二次端子1S1/1S2(保护绕组2S1-2S2)。带电时切勿使CT二次侧开路——会产生危险电压。二次绕组应单点接地。遵循IEC 61869 / GB/T 20840端子标识。 ⚠️ Safety: Follow the nameplate terminal diagram and ground the secondary winding at one point.

标准与合规

符合标准: IEC 61869 / GB/T 20840

  • 型式试验报告: [On Request]
  • 校准证书: [On Request]

负荷与误差计算 (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • 若 S_total < 0.25 × S_rated:需加补偿负荷以维持准确度。
  • 若 S_total > S_rated:无法保证准确级。

产品常见问题

问: 该互感器的绝缘水平是多少?

答: 额定电压0.66kV,绝缘类型为干式环氧树脂,未提及具体冲击耐受水平。

问: 它能否用于保护?

答: 是的,具有0.2/0.5/1.0准确级,适用于测量和保护。

问: 它符合哪些标准?

答: IEC 61869和GB/T 20840。

缺失字段一律标记 [On Request]——绝不编造。M2/M5/M6 验证行遵循 IEC 61869 / IEEE C57.13 惯例。

SPEC · 规格参数表

技术参数 / Technical Specifications

SDH-0.66
11 列 · 149 行

LMK(1,2,3)-0.66, BH, SDH, LN 系列电流互感器

型号额定电流比(A)额定输出(VA)准确级一次匝数穿心匝数外形尺寸穿孔尺寸(宽×高)安装尺寸(宽×高)
WDH
LMK1-0.66/30 (BH-0.66/30)30/510.51178327830×3078×30
40/510.51178327830×3078×30
50/510.51178327830×3078×30
75/520.51178327830×3078×30
100/52.50.51178327830×3078×30
150/52.50.51178327830×3078×30
200/550.51178327830×3078×30
250/550.51178327830×3078×30
300/550.51178327830×3078×30
400/550.51178327830×3078×30
500/550.51178327830×3078×30
600/550.51178327830×3078×30
LMK1-0.66/40 (BH-0.66/40)100/52.50.51185427940×3080×30
150/52.50.51185427940×3080×30
200/550.51185427940×3080×30
250/550.51185427940×3080×30
300/550.51185427940×3080×30
400/550.51185427940×3080×30
500/550.51185427940×3080×30
600/550.51185427940×3080×30
750/550.51185427940×3080×30
800/550.51185427940×3080×30
1000/550.51185427940×3080×30
LMK1-0.66/60 (BH-0.66/60)100/52.50.51190528060×3080×30
150/52.50.51190528060×3080×30
200/550.51190528060×3080×30
250/550.51190528060×3080×30
300/550.51190528060×3080×30
400/550.51190528060×3080×30
500/550.51190528060×3080×30
600/550.51190528060×3080×30
750/550.51190528060×3080×30
800/550.51190528060×3080×30
1000/550.51190528060×3080×30
LMK1-0.66/80 (BH-0.66/80)150/52.50.511105729080×3080×30
200/550.511105729080×3080×30
250/550.511105729080×3080×30
300/550.511105729080×3080×30
400/550.511105729080×3080×30
500/550.511105729080×3080×30
600/550.511105729080×3080×30
750/550.511105729080×3080×30
800/550.511105729080×3080×30
1000/550.511105729080×3080×30
1200/550.511105729080×3080×30
1500/550.511105729080×3080×30
LMK1-0.66/100 (BH-0.66/100)200/550.5111209295100×3080×30
250/550.5111209295100×3080×30
300/550.5111209295100×3080×30
400/550.5111209295100×3080×30
500/550.5111209295100×3080×30
600/550.5111209295100×3080×30
750/550.5111209295100×3080×30
800/550.5111209295100×3080×30
1000/550.5111209295100×3080×30
1200/550.5111209295100×3080×30
1500/550.5111209295100×3080×30
2000/550.5111209295100×3080×30
LMK1-0.66/120 (BH-0.66/120)300/550.511130112100120×3080×30
400/550.511130112100120×3080×30
500/550.511130112100120×3080×30
600/550.511130112100120×3080×30
750/550.511130112100120×3080×30
800/550.511130112100120×3080×30
1000/550.511130112100120×3080×30
1200/550.511130112100120×3080×30
1500/550.511130112100120×3080×30
2000/550.511130112100120×3080×30
LMK2-0.66/30 (SDH-0.66/30)150/52.50.51187409530×3082×30
200/550.51187409530×3082×30
250/550.51187409530×3082×30
300/550.51187409530×3082×30
400/550.51187409530×3082×30
500/550.51187409530×3082×30
600/550.51187409530×3082×30
750/550.51187409530×3082×30
800/550.51187409530×3082×30
1000/550.51187409530×3082×30
LMK2-0.66/40 (SDH-0.66/40)200/550.511904511840×3081×30
250/550.511904511840×3081×30
300/550.511904511840×3081×30
400/550.511904511840×3081×30
500/550.511904511840×3081×30
600/550.511904511840×3081×30
750/550.511904511840×3081×30
800/550.511904511840×3081×30
1000/550.511904511840×3081×30
LMK2-0.66/60 (SDH-0.66/60)300/550.5111026014560×3081×30
400/550.5111026014560×3081×30
500/550.5111026014560×3081×30
600/550.5111026014560×3081×30
750/550.5111026014560×3081×30
800/550.5111026014560×3081×30
1000/550.5111026014560×3081×30
1200/550.5111026014560×3081×30
1500/550.5111026014560×3081×30
LMK2-0.66/80 (SDH-0.66/80)400/550.5111088011880×3081×30
500/550.5111088011880×3081×30
600/550.5111088011880×3081×30
750/550.5111088011880×3081×30
800/550.5111088011880×3081×30
1000/550.5111088011880×3081×30
1200/550.5111088011880×3081×30
1500/550.5111088011880×3081×30
2000/550.5111088011880×3081×30
LMK3-0.66/100 (LN-0.66/100)500/550.51111840122100×3082×30
600/550.51111840122100×3082×30
750/550.51111840122100×3082×30
800/550.51111840122100×3082×30
1000/550.51111840122100×3082×30
1200/550.51111840122100×3082×30
1500/550.51111840122100×3082×30
2000/550.51111840122100×3082×30
LMK3-0.66/120 (LN-0.66/120)600/550.51114052122120×3082×30
750/550.51114052122120×3082×30
800/550.51114052122120×3082×30
1000/550.51114052122120×3082×30
1200/550.51114052122120×3082×30
1500/550.51114052122120×3082×30
2000/550.51114052122120×3082×30
2500/550.51114052122120×3082×30
LMK3-0.66/150 (LN-0.66/150)800/550.51118780132150×30127×30
1000/550.51118780132150×30127×30
1200/550.51118780132150×30127×30
1500/550.51118780132150×30127×30
2000/550.51118780132150×30127×30
2500/550.51118780132150×30127×30
3000/550.51118780132150×30127×30
LMK3-0.66/200 (LN-0.66/200)1000/550.51117680176200×30127×30
1200/550.51117680176200×30127×30
1500/550.51117680176200×30127×30
2000/550.51117680176200×30127×30
2500/550.51117680176200×30127×30
3000/550.51117680176200×30127×30
LMK3-0.66/250 (LN-0.66/250)1500/550.51122780180250×30127×30
2000/550.51122780180250×30127×30
2500/550.51122780180250×30127×30
3000/550.51122780180250×30127×30
4000/550.51122780180250×30127×30
LMK3-0.66/300 (LN-0.66/300)1500/550.51124888178300×40228×40
2000/550.51124888178300×40228×40
2500/550.51124888178300×40228×40
3000/550.51124888178300×40228×40
4000/550.51124888178300×40228×40
LMK3-0.66/400 (LN-0.66/400)2000/550.51127088198400×40228×40
2500/550.51127088198400×40228×40
3000/550.51127088198400×40228×40
4000/550.51127088198400×40228×40
5000/550.51127088198400×40228×40
工程图纸

规格与外形图纸

SDH-0.66 的外形与尺寸图纸 —— 点击图片放大 / 查看原图。

产品概述

关于本产品

SDH-0.66

SDH-0.66 是一款室内低压电流互感器,依据 IEC 61869 和 GB/T 20840 标准框架制造,将 0.66kV 的一次电流降为 5A 或 1A 的二次电流,供计量和控制回路使用。其干式环氧树脂绝缘封装绕组,每台产品出厂前均经过变比和极性例行试验,进一步的试验文件可按需提供。

提供 0.2、0.5 和 1.0 准确级,该产品旨在从轻载到满额定负荷范围内保持其误差带;额定输出(VA)和短时热能力标注于铭牌和官方数据表中。作为单铁芯计量用电流互感器,它适用于仅需测量的开关柜,而计量加保护职责则需要多铁芯对应产品。典型部署于冶金、矿山、水泥和化工厂的配电柜中。

安装前应根据外形图确认安装空间、安全距离和固定方式。一次侧带电时,二次侧绝不能开路。直流和非标准频率不在其适用范围内。OEM 品牌、定制变比和准确级以及文件包可按需提供。

同系列其他型号

同一产品族、不同规格参数 —— 选型前可横向对比。

CGIS1911 电流互感器,适用于CGIS气体绝缘开关设备
35kV
电流互感器50/60Hz

CGIS1911

电流互感器,适用于CGIS气体绝缘开关设备

室内环氧树脂浇注式电流互感器,专为CGIS气体绝缘开关设备设计,具有多种准确级、额定负载和一次电流选项。

准确级详询厂家
绝缘类型干式环氧树脂浇注
额定负荷详询厂家
查看规格
CGIS1775 电流互感器,适用于CGIS气体绝缘开关设备
35kV
电流互感器50/60Hz

CGIS1775

电流互感器,适用于CGIS气体绝缘开关设备

室内环氧树脂浇注式电流互感器,专为CGIS气体绝缘开关设备设计,具有多种准确级、额定负载和一次电流选项。

准确级详询厂家
绝缘类型干式环氧树脂浇注
额定负荷详询厂家
查看规格
CGIS1780 I 电流互感器,应用于CGIS气体绝缘开关设备
35kV
电流互感器50/60Hz

CGIS1780-I

电流互感器,应用于CGIS气体绝缘开关设备

户内环氧树脂浇注式电流互感器,专为CGIS气体绝缘开关设备设计,具有多种准确级、额定输出和一次电流选项。

准确级详询厂家
绝缘类型干式环氧树脂浇注
额定负荷详询厂家
查看规格