中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTSDH-0.66
SDH-0.66 Indoor Low Voltage Current Transformer 0.66kV
0.66kVSDH-0.66
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 0.66kV
Secondary Metering (1S1 - 1S2):5A/1A (0.2/0.5/1.0)
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:SDH-0.66

SDH-0.66 Indoor Low Voltage Current Transformer 0.66kV

SDH-0.66 Indoor Low Voltage Current Transformer 0.66kV is designed for metering and protection in power systems. Key ratings: primary voltage 0.66kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.

Key Engineering Advantages

  • LV current transformer
  • 0.66kV
  • epoxy resin
  • multiple ratios
  • compact design
  • customizable
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: SDH-0.66

Electrical Parameters

Primary Rated Voltage (Un):0.66kV
Secondary Winding Currents:5A/1A
Metering & Protection Class:0.2/0.5/1.0
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Standards Conformance:IEC 61869 / GB/T 20840
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

Indoor LV CT for measurement/protection in 0.66kV systems; compact epoxy resin design for switchgear/panel mounting.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent TransformerIEC 61869 / GB/T 20840
Model CodeSDH-0.66Factory nameplate marking
Primary Voltage0.66kVRated voltage test (IEC 61869-1/3)
Secondary Current5A/1ARatio check at rated frequency
Accuracy Class0.2/0.5/1.0Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
StandardsIEC 61869 / GB/T 20840Certified to listed standards
Frequency50/60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor low voltage switchgear and panels
  • Current measurement and protection in 0.66kV distribution systems
  • Panel mounting with compact space requirements
  • Customizable current ratios and accuracy classes

Not Recommended For

  • Outdoor or high voltage applications
  • High voltage (above 1kV) systems
  • Gas-insulated switchgear (GIS) or SF6 environments
  • Applications requiring high short-circuit withstand capability

Topology & Wiring

secondary terminals 1S1/1S2 (protection winding 2S1-2S2). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869 / GB/T 20840 terminal conventions.

Standards & Compliance

Compliant with: IEC 61869 / GB/T 20840

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the insulation level of this CT?

A: Rated voltage 0.66kV, insulation type dry epoxy resin, no specific impulse withstand mentioned.

Q: Can it be used for protection?

A: Yes, it has accuracy classes 0.2/0.5/1.0, suitable for measurement and protection.

Q: What standards does it comply with?

A: IEC 61869 and GB/T 20840.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

SDH-0.66
11 cols · 149 rows

LMK (1,2,3)-0.66, BH, SDH, LN Series Current Transformer

ModelRated current ratio (A)Rated output (VA)Accuracy classPrimary turnsTurns through coreOverall dimensionsAperture dimensions (W×H)Mounting dimensions (W×H)
WDH
LMK1-0.66/30 (BH-0.66/30)30/510.51178327830×3078×30
40/510.51178327830×3078×30
50/510.51178327830×3078×30
75/520.51178327830×3078×30
100/52.50.51178327830×3078×30
150/52.50.51178327830×3078×30
200/550.51178327830×3078×30
250/550.51178327830×3078×30
300/550.51178327830×3078×30
400/550.51178327830×3078×30
500/550.51178327830×3078×30
600/550.51178327830×3078×30
LMK1-0.66/40 (BH-0.66/40)100/52.50.51185427940×3080×30
150/52.50.51185427940×3080×30
200/550.51185427940×3080×30
250/550.51185427940×3080×30
300/550.51185427940×3080×30
400/550.51185427940×3080×30
500/550.51185427940×3080×30
600/550.51185427940×3080×30
750/550.51185427940×3080×30
800/550.51185427940×3080×30
1000/550.51185427940×3080×30
LMK1-0.66/60 (BH-0.66/60)100/52.50.51190528060×3080×30
150/52.50.51190528060×3080×30
200/550.51190528060×3080×30
250/550.51190528060×3080×30
300/550.51190528060×3080×30
400/550.51190528060×3080×30
500/550.51190528060×3080×30
600/550.51190528060×3080×30
750/550.51190528060×3080×30
800/550.51190528060×3080×30
1000/550.51190528060×3080×30
LMK1-0.66/80 (BH-0.66/80)150/52.50.511105729080×3080×30
200/550.511105729080×3080×30
250/550.511105729080×3080×30
300/550.511105729080×3080×30
400/550.511105729080×3080×30
500/550.511105729080×3080×30
600/550.511105729080×3080×30
750/550.511105729080×3080×30
800/550.511105729080×3080×30
1000/550.511105729080×3080×30
1200/550.511105729080×3080×30
1500/550.511105729080×3080×30
LMK1-0.66/100 (BH-0.66/100)200/550.5111209295100×3080×30
250/550.5111209295100×3080×30
300/550.5111209295100×3080×30
400/550.5111209295100×3080×30
500/550.5111209295100×3080×30
600/550.5111209295100×3080×30
750/550.5111209295100×3080×30
800/550.5111209295100×3080×30
1000/550.5111209295100×3080×30
1200/550.5111209295100×3080×30
1500/550.5111209295100×3080×30
2000/550.5111209295100×3080×30
LMK1-0.66/120 (BH-0.66/120)300/550.511130112100120×3080×30
400/550.511130112100120×3080×30
500/550.511130112100120×3080×30
600/550.511130112100120×3080×30
750/550.511130112100120×3080×30
800/550.511130112100120×3080×30
1000/550.511130112100120×3080×30
1200/550.511130112100120×3080×30
1500/550.511130112100120×3080×30
2000/550.511130112100120×3080×30
LMK2-0.66/30 (SDH-0.66/30)150/52.50.51187409530×3082×30
200/550.51187409530×3082×30
250/550.51187409530×3082×30
300/550.51187409530×3082×30
400/550.51187409530×3082×30
500/550.51187409530×3082×30
600/550.51187409530×3082×30
750/550.51187409530×3082×30
800/550.51187409530×3082×30
1000/550.51187409530×3082×30
LMK2-0.66/40 (SDH-0.66/40)200/550.511904511840×3081×30
250/550.511904511840×3081×30
300/550.511904511840×3081×30
400/550.511904511840×3081×30
500/550.511904511840×3081×30
600/550.511904511840×3081×30
750/550.511904511840×3081×30
800/550.511904511840×3081×30
1000/550.511904511840×3081×30
LMK2-0.66/60 (SDH-0.66/60)300/550.5111026014560×3081×30
400/550.5111026014560×3081×30
500/550.5111026014560×3081×30
600/550.5111026014560×3081×30
750/550.5111026014560×3081×30
800/550.5111026014560×3081×30
1000/550.5111026014560×3081×30
1200/550.5111026014560×3081×30
1500/550.5111026014560×3081×30
LMK2-0.66/80 (SDH-0.66/80)400/550.5111088011880×3081×30
500/550.5111088011880×3081×30
600/550.5111088011880×3081×30
750/550.5111088011880×3081×30
800/550.5111088011880×3081×30
1000/550.5111088011880×3081×30
1200/550.5111088011880×3081×30
1500/550.5111088011880×3081×30
2000/550.5111088011880×3081×30
LMK3-0.66/100 (LN-0.66/100)500/550.51111840122100×3082×30
600/550.51111840122100×3082×30
750/550.51111840122100×3082×30
800/550.51111840122100×3082×30
1000/550.51111840122100×3082×30
1200/550.51111840122100×3082×30
1500/550.51111840122100×3082×30
2000/550.51111840122100×3082×30
LMK3-0.66/120 (LN-0.66/120)600/550.51114052122120×3082×30
750/550.51114052122120×3082×30
800/550.51114052122120×3082×30
1000/550.51114052122120×3082×30
1200/550.51114052122120×3082×30
1500/550.51114052122120×3082×30
2000/550.51114052122120×3082×30
2500/550.51114052122120×3082×30
LMK3-0.66/150 (LN-0.66/150)800/550.51118780132150×30127×30
1000/550.51118780132150×30127×30
1200/550.51118780132150×30127×30
1500/550.51118780132150×30127×30
2000/550.51118780132150×30127×30
2500/550.51118780132150×30127×30
3000/550.51118780132150×30127×30
LMK3-0.66/200 (LN-0.66/200)1000/550.51117680176200×30127×30
1200/550.51117680176200×30127×30
1500/550.51117680176200×30127×30
2000/550.51117680176200×30127×30
2500/550.51117680176200×30127×30
3000/550.51117680176200×30127×30
LMK3-0.66/250 (LN-0.66/250)1500/550.51122780180250×30127×30
2000/550.51122780180250×30127×30
2500/550.51122780180250×30127×30
3000/550.51122780180250×30127×30
4000/550.51122780180250×30127×30
LMK3-0.66/300 (LN-0.66/300)1500/550.51124888178300×40228×40
2000/550.51124888178300×40228×40
2500/550.51124888178300×40228×40
3000/550.51124888178300×40228×40
4000/550.51124888178300×40228×40
LMK3-0.66/400 (LN-0.66/400)2000/550.51127088198400×40228×40
2500/550.51127088198400×40228×40
3000/550.51127088198400×40228×40
4000/550.51127088198400×40228×40
5000/550.51127088198400×40228×40
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of SDH-0.66 — click image to zoom / view original.

Product Overview

About This Product

SDH-0.66

The SDH-0.66 is an indoor low-voltage current transformer built to the IEC 61869 and GB/T 20840 standards framework, stepping primary current at 0.66kV down to a 5A or 1A secondary for metering and control circuits. Its dry epoxy resin insulation encapsulates the winding, and each unit is routine-tested at the factory for ratio and polarity before dispatch, with further test evidence available [On Request].

Accuracy classes 0.2, 0.5 and 1.0 are offered, and the unit is intended to hold its error band from light load through to full rated burden; rated output in VA and short-time thermal capability are stated on the nameplate and official datasheet. As a single-core metering CT it suits panels where only measurement is required, while metering-plus-protection duties call for a multi-core counterpart. Typical deployment is distribution boards in metallurgical, mining, cement and chemical plants.

Mounting space, safety clearances and fixing arrangement should be confirmed against the outline drawing before installation. The secondary must never be open-circuited while the primary is energized. DC and non-standard frequencies are outside its scope. OEM branding, customized ratios and accuracy classes, and a document package are available on request.

Other Models in This Series

Same product family, different ratings — compare before you specify.

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1911

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1775

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1780-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs