CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Indoor epoxy resin CT for CGIS at 35kV, 50/60Hz. Suitable for protection and metering in gas-insulated switchgear.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | CGIS1775 | Factory nameplate marking |
| Primary Voltage | 35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary through the window. Secondary terminals: 1S1/1S2 for metering, 2S1/2S2 for protection. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the primary voltage rating?
A: 35kV
Q: What is the insulation type?
A: Dry epoxy resin
Q: What is the inner window diameter?
A: Φ75mm
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Accuracy class | Rated output (VA) | 40 | 50 | 60 | 75 | 100 | 125 | 150 | 200 | 250 | 300 | 400 | 500 | 600 | 750 | 1000 | 1200 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.2FS10 / 0.5FS10 | 2.5 | — | — | — | — | — | 65 | 55 | 40 | 35 | 30 | 30 | 30 | 30 | 35 | 35 | 35 |
| 0.2FS10 / 0.5FS10 | 5 | — | — | — | — | — | 96 | 80 | 55 | 50 | 35 | 30 | 30 | 30 | 35 | 35 | 35 |
| 0.2FS10 / 0.5FS10 | 10 | — | — | — | — | — | 120 | 80 | 60 | 45 | 35 | 35 | 30 | 35 | 35 | 35 | 35 |
| 0.2FS10 / 0.5FS10 | 15 | — | — | — | — | — | 110 | 70 | 55 | 45 | 40 | 35 | 35 | 35 | 35 | 35 | 35 |
| 0.2FS10 / 0.5FS10 | 20 | — | — | — | — | — | 145 | 90 | 65 | 55 | 45 | 40 | 40 | 35 | 35 | 35 | 35 |
| 0.2FS10 / 0.5FS10 | 25 | — | — | — | — | — | 160 | 110 | 75 | 60 | 50 | 45 | 45 | 40 | 35 | 35 | 35 |
| 0.2FS10 / 0.5FS10 | 30 | — | — | — | — | — | 125 | 85 | 70 | 50 | 55 | 50 | 45 | 40 | 35 | 35 | 35 |
| 0.5 | 2.5 | — | — | — | 55 | 45 | 40 | 35 | 30 | 30 | 25 | 25 | 25 | 25 | 25 | 25 | — |
| 0.5 | 5 | — | — | — | 80 | 65 | 50 | 40 | 30 | 30 | 25 | 25 | 25 | 25 | 25 | 25 | — |
| 0.5 | 10 | — | — | — | 125 | 95 | 75 | 55 | 40 | 35 | 30 | 25 | 25 | 25 | 25 | 25 | — |
| 0.5 | 15 | — | — | — | 125 | 95 | 70 | 55 | 45 | 40 | 35 | 30 | 25 | 25 | 25 | 25 | — |
| 0.5 | 20 | — | — | — | 120 | 85 | 65 | 55 | 50 | 40 | 35 | 30 | 25 | 25 | 25 | 25 | — |
| 0.5 | 25 | — | — | — | 95 | 75 | 65 | 55 | 45 | 35 | 30 | 25 | 25 | 25 | 25 | 25 | — |
| 0.5 | 30 | — | — | — | — | — | 65 | 70 | 55 | 45 | 35 | 30 | 25 | 25 | 25 | 25 | 25 |
| 5(10)P10 | 2.5 | 135 | 100 | 85 | 75 | 55 | 45 | 40 | 35 | 60 | 30 | 30 | 30 | 30 | 30 | 25 | 25 |
| 5(10)P10 | 5 | — | 135 | 120 | 85 | 70 | 55 | 50 | 45 | 40 | 40 | 35 | 35 | 35 | 35 | 30 | 30 |
| 5(10)P10 | 10 | — | — | 145 | 110 | 95 | 80 | 70 | 60 | 60 | 50 | 45 | 45 | 35 | 35 | 35 | 35 |
| 5(10)P10 | 15 | — | — | 155 | 130 | 110 | 90 | 80 | 80 | 65 | 60 | 50 | 45 | 40 | 40 | 40 | 40 |
| 5(10)P10 | 20 | — | — | 115 | 100 | 95 | 85 | 80 | 70 | 70 | 60 | 50 | 45 | 45 | 45 | 45 | 45 |
| 5(10)P10 | 25 | — | — | 140 | 120 | 115 | 95 | 80 | 70 | 80 | 70 | 60 | 55 | 50 | 50 | 50 | 50 |
| 5(10)P10 | 30 | — | — | — | — | 130 | 110 | 110 | 95 | 80 | 70 | 70 | 60 | 55 | 55 | 55 | 55 |
| 5(10)P20 | 2.5 | — | 145 | 125 | 90 | 75 | 65 | 60 | 50 | 50 | 50 | 45 | 40 | 40 | 35 | 35 | 35 |
| 5(10)P20 | 5 | — | — | 145 | 115 | 95 | 90 | 75 | 70 | 65 | 55 | 50 | 50 | 45 | 40 | 40 | 40 |
| 5(10)P20 | 10 | — | — | — | — | 156 | 125 | 110 | 105 | 85 | 75 | 70 | 60 | 55 | 55 | 55 | 55 |
| 5(10)P20 | 15 | — | — | — | — | 150 | 140 | 115 | 100 | 90 | 75 | 70 | 65 | 60 | 60 | 60 | 60 |
| 5(10)P20 | 20 | — | — | — | — | — | 145 | 125 | 115 | 100 | 90 | 75 | 70 | 65 | 60 | 60 | 60 |
| 5(10)P20 | 25 | — | — | — | — | — | — | 150 | 135 | 105 | 95 | 85 | 80 | 80 | 80 | 80 | 80 |
| 5(10)P20 | 30 | — | — | — | — | — | — | 155 | 120 | 105 | 95 | 85 | 80 | 80 | 80 | 80 | 80 |
| 5(10)P30 | 2.5 | — | — | 130 | 105 | 90 | 85 | 75 | 70 | 65 | 55 | 55 | 55 | 55 | 50 | 50 | — |
| 5(10)P30 | 5 | — | — | 145 | 135 | 115 | 100 | 95 | 80 | 75 | 75 | 75 | 65 | 60 | 60 | 60 | — |
| 5(10)P30 | 10 | — | — | — | — | 170 | 155 | 125 | 115 | 110 | 90 | 80 | 80 | 80 | 80 | 80 | — |
| 5(10)P30 | 15 | — | — | — | — | — | 155 | 140 | 115 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | — |
| 5(10)P30 | 20 | — | — | — | — | — | — | — | 140 | 125 | 125 | 125 | 125 | 125 | 125 | 125 | — |
| 5(10)P30 | 25 | — | — | — | — | — | — | — | — | 145 | 145 | 145 | 145 | 145 | 145 | 145 | — |
Dimension & outline drawing of CGIS1775 — click image to zoom / view original.
The CGIS1775 is a 35 kV indoor epoxy resin cast current transformer for CGIS gas insulated switchgear, built to feed accurate current signals to revenue metering and protection relays. Its 0.2FS10 and 0.5FS10 accuracy classes support billing-grade measurement, with rated outputs from 2.5 VA to 30 VA depending on the selected ratio.
The square housing with a Φ75 mm inner window keeps the unit compact inside the switchgear cubicle, reducing the panel space needed for primary conductor routing. The dry epoxy resin casting provides the insulation, and the design operates at 50/60 Hz. Secondary burden should be matched to the nameplate VA to preserve accuracy; the parameter table shows, for example, 65 VA at 0.2FS10/0.5FS10 with 2.5 VA rated output, and 120 VA at 10 VA.
Compliance follows the GB/T 20840 series, with test reports and routine documents available [On Request]. The unit is for indoor service only and must not be installed outdoors. The secondary circuit must never be open-circuited while energized. Ratio and accuracy class customization, OEM branding and document packages are available on request.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 II Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-II) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.