KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTCGIS1775
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kVCGIS1775
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 35kV
Secondary Metering (1S1 - 1S2): ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:CGIS1775

CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Key Engineering Advantages

  • Indoor epoxy resin casting current transformer for CGIS
  • square housing with Φ75mm inner window
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: CGIS1775

Electrical Parameters

Primary Rated Voltage (Un):35kV
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

Indoor epoxy resin CT for CGIS at 35kV, 50/60Hz. Suitable for protection and metering in gas-insulated switchgear.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeCGIS1775Factory nameplate marking
Primary Voltage35kVRated voltage test (IEC 61869-1/3)
Secondary Current[On Request]Ratio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50/60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • CGIS gas insulated switchgear indoor installations
  • 35kV power systems
  • Metering and protection applications
  • 50/60Hz networks

Not Recommended For

  • Outdoor installations
  • Voltage transformation
  • Non-gas-insulated switchgear
  • Systems above 35kV

Topology & Wiring

Connect primary through the window. Secondary terminals: 1S1/1S2 for metering, 2S1/2S2 for protection. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the primary voltage rating?

A: 35kV

Q: What is the insulation type?

A: Dry epoxy resin

Q: What is the inner window diameter?

A: Φ75mm

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

CGIS1775
18 cols · 34 rows

CGIS1775 Current Transformer for Gas-Insulated Switchgear — Technical Data

Accuracy classRated output (VA)4050607510012515020025030040050060075010001200
0.2FS10 / 0.5FS102.5—————6555403530303030353535
0.2FS10 / 0.5FS105—————9680555035303030353535
0.2FS10 / 0.5FS1010—————12080604535353035353535
0.2FS10 / 0.5FS1015—————11070554540353535353535
0.2FS10 / 0.5FS1020—————14590655545404035353535
0.2FS10 / 0.5FS1025—————160110756050454540353535
0.2FS10 / 0.5FS1030—————12585705055504540353535
0.52.5———554540353030252525252525—
0.55———806550403030252525252525—
0.510———1259575554035302525252525—
0.515———1259570554540353025252525—
0.520———1208565555040353025252525—
0.525———957565554535302525252525—
0.530—————6570554535302525252525
5(10)P102.51351008575554540356030303030302525
5(10)P105—13512085705550454040353535353030
5(10)P1010——145110958070606050454535353535
5(10)P1015——1551301109080806560504540404040
5(10)P1020——115100958580707060504545454545
5(10)P1025——1401201159580708070605550505050
5(10)P1030————130110110958070706055555555
5(10)P202.5—14512590756560505050454040353535
5(10)P205——145115959075706555505045404040
5(10)P2010————1561251101058575706055555555
5(10)P2015————1501401151009075706560606060
5(10)P2020—————14512511510090757065606060
5(10)P2025——————15013510595858080808080
5(10)P2030——————15512010595858080808080
5(10)P302.5——1301059085757065555555555050—
5(10)P305——145135115100958075757565606060—
5(10)P3010————170155125115110908080808080—
5(10)P3015—————155140115100100100100100100100—
5(10)P3020———————140125125125125125125125—
5(10)P3025————————145145145145145145145—
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of CGIS1775 — click image to zoom / view original.

Product Overview

About This Product

CGIS1775

The CGIS1775 is a 35 kV indoor epoxy resin cast current transformer for CGIS gas insulated switchgear, built to feed accurate current signals to revenue metering and protection relays. Its 0.2FS10 and 0.5FS10 accuracy classes support billing-grade measurement, with rated outputs from 2.5 VA to 30 VA depending on the selected ratio.

The square housing with a Φ75 mm inner window keeps the unit compact inside the switchgear cubicle, reducing the panel space needed for primary conductor routing. The dry epoxy resin casting provides the insulation, and the design operates at 50/60 Hz. Secondary burden should be matched to the nameplate VA to preserve accuracy; the parameter table shows, for example, 65 VA at 0.2FS10/0.5FS10 with 2.5 VA rated output, and 120 VA at 10 VA.

Compliance follows the GB/T 20840 series, with test reports and routine documents available [On Request]. The unit is for indoor service only and must not be installed outdoors. The secondary circuit must never be open-circuited while energized. Ratio and accuracy class customization, OEM branding and document packages are available on request.

Other Models in This Series

Same product family, different ratings — compare before you specify.

CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS2010

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1780-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1780 II Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1780-II

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1780 II Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-II) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs