CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Indoor epoxy resin cast CT for CGIS, rated 35kV, 50/60Hz. Suitable for metering and protection in gas-insulated switchgear.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | CGIS2010 | Factory nameplate marking |
| Primary Voltage | 35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
connect primary through window; secondary terminals 1S1/1S2 for main winding, 2S1/2S2 for protection if present. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point only. Follow IEC 61869-2 terminal markings.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation type?
A: Dry epoxy resin casting.
Q: What is the primary voltage rating?
A: 35kV.
Q: What is the frequency range?
A: 50/60Hz.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Accuracy class | Rated output (VA) | 40 | 50 | 60 | 75 | 100 | 125 | 150 | 200 | 250 | 300 | 400 | 500 | 600 | 750 | 1000 | 1200 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.2S FS10 / 0.2 FS10 / 0.5S FS10 | 2.5 | — | — | — | — | 85 | 60 | 50 | 35 | 30 | 30 | 30 | 30 | 35 | 35 | 35 | 35 |
| 5 | — | — | — | — | 130 | 90 | 70 | 50 | 40 | 35 | 30 | 30 | 30 | 35 | 35 | 35 | |
| 10 | — | — | — | — | 150 | 115 | 75 | 55 | 45 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | |
| 15 | — | — | — | — | — | 160 | 100 | 70 | 55 | 45 | 40 | 35 | 35 | 35 | 35 | 35 | |
| 0.5 FS10 | 2.5 | — | — | 115 | 80 | 50 | 40 | 35 | 30 | 30 | 30 | 25 | 25 | 25 | 25 | 25 | — |
| 5 | — | — | — | 120 | 75 | 60 | 45 | 35 | 30 | 30 | 30 | 25 | 25 | 25 | 25 | — | |
| 10 | — | — | — | — | 120 | 90 | 70 | 50 | 40 | 35 | 30 | 25 | 25 | 25 | 25 | — | |
| 15 | — | — | — | — | 120 | 90 | 65 | 55 | 45 | 40 | 35 | 30 | 25 | 25 | 25 | — | |
| 5P10 / 10P10 | 2.5 | 135 | 100 | 85 | 75 | 55 | 45 | 40 | 35 | 30 | 30 | 30 | 30 | 30 | 30 | 25 | 25 |
| 5 | — | — | 135 | 120 | 85 | 70 | 55 | 50 | 45 | 40 | 35 | 35 | 35 | 35 | 30 | 30 | |
| 10 | — | — | — | 145 | 110 | 95 | 80 | 70 | 60 | 50 | 45 | 45 | 45 | 35 | 35 | — | |
| 15 | — | — | — | — | 155 | 130 | 110 | 90 | 80 | 80 | 65 | 60 | 50 | 45 | 40 | — | |
| 5P20 / 10P20 | 2.5 | — | — | 145 | 125 | 90 | 75 | 65 | 60 | 50 | 50 | 50 | 45 | 40 | 40 | 35 | 35 |
| 5 | — | — | — | 145 | 115 | 95 | 90 | 75 | 70 | 65 | 55 | 50 | 50 | 45 | 40 | — | |
| 10 | — | — | — | — | — | 150 | 125 | 110 | 105 | 85 | 75 | 70 | 60 | 55 | 55 | — | |
| 15 | — | — | — | — | — | — | — | 150 | 140 | 115 | 100 | 90 | 75 | 70 | 70 | — | |
| 5P30 / 10P30 | 2.5 | — | — | 155 | 135 | 100 | 85 | 75 | 70 | 60 | 60 | 60 | 50 | 50 | 45 | 45 | — |
| 5 | — | — | — | 155 | 125 | 105 | 100 | 85 | 80 | 75 | 65 | 60 | 50 | 55 | 50 | — | |
| 10 | — | — | — | — | — | 160 | 135 | 120 | 115 | 95 | 85 | 80 | 70 | 65 | 65 | — | |
| 15 | — | — | — | — | — | — | — | 160 | 150 | 125 | 110 | 100 | 85 | 80 | 80 | — |
Dimension & outline drawing of CGIS2010 — click image to zoom / view original.
This is an indoor dry epoxy resin cast current transformer for 35kV CGIS gas insulated switchgear, converting primary current into a standard secondary signal for metering and protection. The chamfered square housing with a Ø105mm inner window is cast in epoxy resin, giving a compact, maintenance-free insulation structure suited to the confined cable and busbar compartments of gas insulated switchgear.
Accuracy classes 0.2S FS10, 0.2 FS10, 0.5S FS10 and 0.5 FS10 are available, with rated outputs from 2.5VA to 15VA depending on the ratio and class; for example, class 0.5 FS10 at 5VA delivers 120VA at the 75A column and 30VA at 300A. Protection cores 5P10 and 10P10 are also listed. Compliance follows the IEC 61869 series, with routine and type test documentation available [On Request].
Deployed in medium-voltage switchgear and ring main units, the unit requires the secondary circuit to be earthed at one point and never open-circuited while energized. Overspecifying accuracy wastes budget; confirm the ratio and burden against the nameplate. Custom ratios, winding configurations and document packages are quoted on request.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.