CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Indoor epoxy resin CT for 35kV CGIS switchgear; multiple accuracy and burden options.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | CGIS1911 | Factory nameplate marking |
| Primary Voltage | 35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
For current transformers, adhere to IEC 61869-2 terminal markings: primary P1/P2, secondary 1S1/1S2 (protection winding 2S1-2S2 if applicable). Never open-circuit the secondary of a CT while energized - hazardous voltage may occur. Ground the secondary circuit at one point only. Ensure correct polarity for differential or directional protection. Verify rated burden and accuracy class before energizing.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the primary voltage rating of this CT?
A: The primary voltage is 35kV.
Q: Can this CT be used outdoors?
A: No, it is designed for indoor use within CGIS switchgear.
Q: What is the inner window diameter?
A: The inner window diameter is Ø106mm.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Accuracy class | Rated output (VA) | Rated primary current (A) | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| (50) | (60) | (75) | (100) | (125) | (150) | (200) | (250) | (300) | (400) | (500) | (600) | (750) | (1000) | (1200) | ||
| 0.2FS10 / 0.5FS10 | 2.5 | — | — | — | 130 | 100 | 85 | 45 | 35 | 30 | 30 | 30 | 30 | 35 | 35 | — |
| 5 | — | — | — | 165 | 100 | 65 | 50 | 40 | 30 | 30 | 30 | 30 | 35 | 35 | — | |
| 10 | — | — | — | — | — | 165 | 100 | 70 | 50 | 35 | 30 | 30 | 35 | 35 | — | |
| 15 | — | — | — | — | — | 140 | 95 | 65 | 45 | 40 | 35 | 35 | 35 | 35 | — | |
| 20 | — | — | — | — | — | 175 | 120 | 80 | 50 | 45 | 40 | 40 | 40 | 35 | — | |
| 25 | — | — | — | — | — | 145 | 95 | 60 | 50 | 45 | 45 | 45 | 40 | 40 | — | |
| 30 | — | — | — | — | — | — | 170 | 110 | 65 | 55 | 50 | 50 | 45 | 45 | — | |
| 0.5FS10 | 2.5 | — | 165 | 115 | 75 | 55 | 45 | 35 | 30 | 30 | 25 | 20 | 20 | 20 | 25 | — |
| 5 | — | — | 115 | 80 | 65 | 40 | 35 | 30 | 30 | 25 | 20 | 20 | 20 | 25 | — | |
| 10 | — | — | — | 130 | 100 | 60 | 50 | 40 | 35 | 30 | 25 | 20 | 20 | 25 | — | |
| 15 | — | — | — | 135 | 80 | 60 | 50 | 45 | 35 | 30 | 25 | 20 | 25 | — | — | |
| 20 | — | — | — | — | 95 | 75 | 65 | 50 | 40 | 30 | 25 | 20 | 25 | — | — | |
| 25 | — | — | — | — | 115 | 90 | 75 | 55 | 60 | 35 | 30 | 25 | 25 | — | — | |
| 30 | — | — | — | — | 135 | 105 | 85 | 65 | 55 | 35 | 30 | 25 | 25 | — | — | |
| 5P10 / 10P10 | 2.5 | 150 | 110 | 75 | 70 | 55 | 45 | 35 | 30 | 30 | 25 | 25 | 25 | 20 | 25 | — |
| 5 | — | 175 | 135 | 105 | 85 | 70 | 55 | 45 | 40 | 35 | 35 | 30 | 25 | 30 | — | |
| 10 | — | — | 185 | 145 | 115 | 85 | 70 | 60 | 55 | 45 | 40 | 35 | 30 | 35 | — | |
| 15 | — | — | — | 160 | 115 | 95 | 80 | 70 | 60 | 55 | 45 | 40 | 45 | — | — | |
| 20 | — | — | — | 150 | 120 | 100 | 90 | 75 | 65 | 55 | 45 | 40 | 45 | — | — | |
| 25 | — | — | — | 185 | 145 | 120 | 105 | 90 | 75 | 65 | 55 | 55 | 55 | — | — | |
| 30 | — | — | — | — | 170 | 140 | 125 | 105 | 90 | 75 | 80 | 65 | 60 | — | — | |
| 5P20 / 10P20 | 2.5 | — | 180 | 145 | 115 | 90 | 75 | 60 | 50 | 45 | 40 | 35 | 35 | 30 | 35 | — |
| 5 | — | — | 185 | 145 | 120 | 90 | 75 | 65 | 60 | 50 | 45 | 40 | 40 | 45 | — | |
| 10 | — | — | — | 200 | 150 | 120 | 105 | 95 | 80 | 70 | 60 | 50 | 45 | — | — | |
| 15 | — | — | — | — | 165 | 145 | 130 | 105 | 95 | 80 | 85 | 70 | 60 | — | — | |
| 20 | — | — | — | — | 185 | 160 | 135 | 115 | 100 | 80 | 85 | 80 | — | — | — | |
| 25 | — | — | — | — | — | 195 | 160 | 140 | 120 | 95 | 100 | — | — | — | — | |
| 30 | — | — | — | — | — | 190 | 165 | 140 | 110 | 115 | — | — | — | — | — | |
| 5P30 / 10P30 | 2.5 | — | — | 200 | 160 | 130 | 105 | 85 | 70 | 60 | 55 | 50 | 45 | 40 | 45 | — |
| 5 | — | — | — | 170 | 135 | 110 | 95 | 85 | 70 | 65 | 60 | 55 | 60 | 80 | — | |
| 10 | — | — | — | — | — | 190 | 160 | 135 | 115 | 105 | 90 | 80 | 80 | — | — | |
| 15 | — | — | — | — | — | — | 190 | 160 | 140 | 120 | 100 | 105 | — | — | — | |
| 20 | — | — | — | — | — | — | — | 175 | 155 | 125 | 125 | — | — | — | — | |
| 25 | — | — | — | — | — | — | — | — | 190 | 150 | 150 | — | — | — | — | |
| 30 | — | — | — | — | — | — | — | — | — | 175 | 175 | — | — | — | — | |
Dimension & outline drawing of CGIS1911 — click image to zoom / view original.
The CGIS1911 is an indoor epoxy resin casting current transformer for 35kV gas insulated switchgear, used to step primary current down to a measurable secondary level for protection and metering. Its square housing carries a Ø106mm inner window, and the dry epoxy resin body insulates the windings without oil or gas.
Accuracy classes cover 0.2FS10, 0.5SFS10, 0.5FS10, 5P10, 10P10, 5P200 and 10P20 at 50/60Hz. Rated output in VA depends on the class and primary current; for example, 0.2FS10 / 0.5FS10 at 2.5VA is listed from 130VA at 100A down to 30VA at 300A and above, while 0.5FS10 at 2.5VA reaches 165VA at 60A. Exact figures for a given ratio are on the nameplate and datasheet. Routine factory checks include ratio and polarity verification, with partial discharge screening available [On Request].
This unit suits heavy-industry distribution boards in metallurgy, mining, cement and chemical plants. Fit it on the switchgear busbar, earth the secondary at one point, and never open-circuit the secondary while energized. It is not intended for DC or non-standard frequencies. Ratio and class combinations are customized; request the test certificate package and lead time with your inquiry.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.