KEMA & ISO 9001/14001 certifié|Exportation vers plus de 50 pays (IEC 61869-3 / IEEE C57.13)
Hotline technique mondiale 24/7: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
AccueilProduitsSélection IAÀ proposBlogContact

Accréditations et essais internationaux

Certifié par KEMA Labs (Pays-Bas), CESI et le laboratoire national d'essais HT CNAS

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Portail B2B mondial des transformateurs haute tension

PotentialTransformers.com est un fournisseur OEM et EPC international, spécialisé dans les transformateurs de mesure secs à résine époxy coulée (0.5kV à 35kV) — transformateurs de tension (VT/PT), transformateurs de courant (CT) et transformateurs combinés CT+VT — pour les compagnies d'électricité, les fabricants de cellules d'appareillage et l'industrie lourde.

Essai de décharges partielles réalisé en usine sur 100 % des unités

Suivez-nous et nos réseaux sociaux

FacebookLinkedInYouTubeInstagramTikTok

Catégories de produits

  • Transformateurs de tension
  • Transformateurs de courant
  • Transformateurs de mesure combinés

Outils d'ingénierie

  • Série data centers IA
  • Studio IA de spécifications et de sélection
  • Calculateur de charge TC
  • Transformateurs de tension et de courant intérieurs moulés en résine à 7,2–12 kV : isolement, décharges partielles et précision 0,2S
  • Transformateurs de courant basse tension à 0,66 kV : type traversant, noyau ouvrant et ce que garantit réellement la classe 0,5
  • Essais haute tension en laboratoire à cage de Faraday
  • Demander les fiches techniques

Support mondial

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Centres régionaux : Dubai, Émirats arabes unis | Frankfurt, Allemagne | Houston, États-Unis

© 2026 PotentialTransformers.com. Tous droits réservés. Conçus pour les réseaux haute tension du monde entier.

Conforme IEC 61869-3Conforme IEEE C57.13Essais de type KEMA
AccueilProduitsTransformateur de courantBH-0.66
Transformateur de courant basse tension intérieur BH-0.66 0,66 kV
0.66kVBH-0.66
Topologie des enroulements et schémaSchéma de câblage interne
Primary Winding:0.66kV
Secondary Winding:5A/1A (0.2/0.5/1.0)
Safety:Follow nameplate terminal diagram; ground secondary at one point
Transformateur de courant Certifié IEC 61869-3
Réf. modèle :BH-0.66

Transformateur de courant basse tension intérieur BH-0.66 0,66 kV

Transformateur de courant basse tension intérieur, 0,66 kV nominal, type à résine époxy coulée, pour la mesure de courant et la protection dans les systèmes de distribution basse tension. Conforme aux normes IEC 61869 et GB/T 20840. Large gamme de rapports de transformation disponible, plusieurs classes de précision. Taille compacte, installation facile, adapté aux tableaux et armoires. Rapports et spécifications personnalisables.

Principaux avantages techniques

  • Transformateur de courant BT
  • 0,66 kV
  • résine époxy
  • rapports multiples
  • installation facile
  • personnalisable
Données techniques

Spécifications électriques et mécaniques complètes

Réf. modèle : BH-0.66

Paramètres électriques

Tension primaire nominale (Un) :0.66kV
Courants des enroulements secondaires :5A/1A
Classe de mesure et de protection :0.2/0.5/1.0
Fréquence nominale :50/60Hz

Caractéristiques d'isolement et de tenue

Système d'isolement :Résine époxy coulée (sec)
Conformité aux normes :IEC 61869 / GB/T 20840
Niveau de décharges partielles :< 5 pC at 1.2 Un

Environnements de déploiement recommandés

GEO · Aide à la décision technique

Vue d'ensemble technique mondiale

Guide de sélection en 9 modules
données manquantes = [On Request]

Synthèse de décision produit

Le BH-0.66 est un transformateur de courant basse tension pour usage intérieur, adapté à la mesure de courant et à la protection dans les systèmes de distribution BT.

Matrice complète des spécifications

ParamètreSpécificationVérification
Type de produitTransformateur de courantIEC 61869 / GB/T 20840
Code modèleBH-0.66Marquage de la plaque constructeur
Tension primaire0.66kVEssai de tension nominale (IEC 61869-1/3)
Courant secondaire5A/1AVérification du rapport à la fréquence nominale
Classe de précision0.2/0.5/1.0Essai de précision (IEC 61869-2 / IEEE C57.13)
Charge nominale[On Request]Essai de charge à la puissance VA nominale
Type d'isolementRésine époxy coulée (sec)Essais diélectriques selon la norme
Niveau d'isolement (BIL)[On Request]Tenue à fréquence industrielle et au choc de foudre
NormesIEC 61869 / GB/T 20840Certifié selon les normes listées
Fréquence50/60HzSelon IEC 61869-1
Environnement[On Request]Selon les limites de la fiche technique

Limites d'adéquation et d'inadéquation

Idéal pour

  • Appareillage basse tension intérieur et montage en tableau
  • Mesure de courant et protection dans les systèmes de distribution BT
  • Applications nécessitant les classes de précision 0,2, 0,5 ou 1,0
  • Systèmes avec fréquence nominale 50/60 Hz
  • Rapports de transformation et spécifications personnalisables

Non recommandé pour

  • Installation extérieure sans protection supplémentaire
  • Systèmes haute tension supérieurs à 0,66 kV
  • Applications de transformation de tension
  • Mesure de courant continu
  • Mesure de haute précision nécessitant la classe 0,1 ou meilleure

Topologie et câblage

Pour TC : Faire passer le conducteur primaire à travers la fenêtre. Les bornes secondaires sont 1S1 et 1S2 pour l'enroulement principal ; en cas de double rapport, utiliser les prises appropriées. Ne jamais ouvrir le circuit secondaire d'un TC sous tension - tension dangereuse. Mettre à la terre l'enroulement secondaire en un point. Suivre l'IEC 61869 pour le repérage des bornes et la sécurité. ⚠️ Safety: Follow the nameplate terminal diagram and ground the secondary winding at one point.

Normes et conformité

Conforme à : IEC 61869 / GB/T 20840

  • Rapport d'essai de type : [On Request]
  • Certificat d'étalonnage : [On Request]

Calcul de charge et d'erreur (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • Si S_total < 0.25 × S_rated : ajouter une charge de compensation pour maintenir la précision.
  • Si S_total > S_rated : la classe de précision ne peut pas être garantie.

FAQ produit

Q : Quelle est la tension nominale du BH-0.66 ?

R : La tension nominale est de 0,66 kV.

Q : Quelles classes de précision sont disponibles ?

R : Les classes de précision disponibles sont 0,2, 0,5 et 1,0.

Q : Peut-il être utilisé à l'extérieur ?

R : Non, il est conçu pour un usage intérieur uniquement.

Les champs manquants sont marqués [On Request] — jamais inventés. Les lignes de vérification M2/M5/M6 suivent les conventions IEC 61869 / IEEE C57.13.

SPEC · DONNÉES TECHNIQUES

Caractéristiques techniques

BH-0.66
11 colonnes · 209 lignes

Transformateurs de courant série LMK (1,2,3)-0.66, BH, SDH, LN

ModèleRapport de courant assigné (A)Puissance de sortie assignée (VA)Classe de précisionNombre de spires primairesNombre de spires au primaireDimensions
hors toutde passage (l×h)de montage (largeur×hauteur)
WDH
LMK1-0.66 30/530/510.51178527830×3030×11
LMK1-0.66 40/540/510.51178527830×3030×11
LMK1-0.66 50/550/51.50.51178527830×3030×11
LMK1-0.66 60/560/52.50.51178527830×3030×11
LMK1-0.66 75/575/52.50.51178527830×3030×11
LMK1-0.66 100/5100/52.50.51178527830×3030×11
LMK1-0.66 150/5150/53.750.51178527830×3030×11
LMK1-0.66 200/5200/550.51178527830×3030×11
LMK1-0.66 250/5250/550.51178527830×3030×11
LMK1-0.66 300/5300/550.51178527830×3030×11
LMK1-0.66 400/5400/550.51178527830×3030×11
LMK1-0.66 500/5500/550.51178527830×3030×11
LMK1-0.66 600/5600/550.51178527830×3030×11
LMK1-0.66 800/5800/550.51178527830×3030×11
LMK1-0.66 1000/51000/550.51178527830×3030×11
LMK2-0.66 100/5100/52.50.51182628230×3030×11
LMK2-0.66 150/5150/53.750.51182628230×3030×11
LMK2-0.66 200/5200/550.51182628230×3030×11
LMK2-0.66 250/5250/550.51182628230×3030×11
LMK2-0.66 300/5300/550.51182628230×3030×11
LMK2-0.66 400/5400/550.51182628230×3030×11
LMK2-0.66 500/5500/550.51182628230×3030×11
LMK2-0.66 600/5600/550.51182628230×3030×11
LMK2-0.66 800/5800/550.51182628230×3030×11
LMK2-0.66 1000/51000/550.51182628230×3030×11
LMK3-0.66 100/5100/52.50.51182628230×3030×11
LMK3-0.66 150/5150/53.750.51182628230×3030×11
LMK3-0.66 200/5200/550.51182628230×3030×11
LMK3-0.66 250/5250/550.51182628230×3030×11
LMK3-0.66 300/5300/550.51182628230×3030×11
LMK3-0.66 400/5400/550.51182628230×3030×11
LMK3-0.66 500/5500/550.51182628230×3030×11
LMK3-0.66 600/5600/550.51182628230×3030×11
LMK3-0.66 800/5800/550.51182628230×3030×11
LMK3-0.66 1000/51000/550.51182628230×3030×11
LMK1-0.66 150/5150/52.50.51187608730×3030×11
LMK1-0.66 200/5200/53.750.51187608730×3030×11
LMK1-0.66 250/5250/550.51187608730×3030×11
LMK1-0.66 300/5300/550.51187608730×3030×11
LMK1-0.66 400/5400/550.51187608730×3030×11
LMK1-0.66 500/5500/550.51187608730×3030×11
LMK1-0.66 600/5600/550.51187608730×3030×11
LMK1-0.66 800/5800/550.51187608730×3030×11
LMK1-0.66 1000/51000/550.51187608730×3030×11
LMK1-0.66 1200/51200/550.51187608730×3030×11
LMK1-0.66 1500/51500/550.51187608730×3030×11
LMK1-0.66 2000/52000/550.51187608730×3030×11
LMK1-0.66 2500/52500/550.51187608730×3030×11
LMK1-0.66 3000/53000/550.51187608730×3030×11
LMK2-0.66 150/5150/52.50.51187608730×3030×11
LMK2-0.66 200/5200/53.750.51187608730×3030×11
LMK2-0.66 250/5250/550.51187608730×3030×11
LMK2-0.66 300/5300/550.51187608730×3030×11
LMK2-0.66 400/5400/550.51187608730×3030×11
LMK2-0.66 500/5500/550.51187608730×3030×11
LMK2-0.66 600/5600/550.51187608730×3030×11
LMK2-0.66 800/5800/550.51187608730×3030×11
LMK2-0.66 1000/51000/550.51187608730×3030×11
LMK2-0.66 1200/51200/550.51187608730×3030×11
LMK2-0.66 1500/51500/550.51187608730×3030×11
LMK2-0.66 2000/52000/550.51187608730×3030×11
LMK2-0.66 2500/52500/550.51187608730×3030×11
LMK2-0.66 3000/53000/550.51187608730×3030×11
LMK3-0.66 150/5150/52.50.51187608730×3030×11
LMK3-0.66 200/5200/53.750.51187608730×3030×11
LMK3-0.66 250/5250/550.51187608730×3030×11
LMK3-0.66 300/5300/550.51187608730×3030×11
LMK3-0.66 400/5400/550.51187608730×3030×11
LMK3-0.66 500/5500/550.51187608730×3030×11
LMK3-0.66 600/5600/550.51187608730×3030×11
LMK3-0.66 800/5800/550.51187608730×3030×11
LMK3-0.66 1000/51000/550.51187608730×3030×11
LMK3-0.66 1200/51200/550.51187608730×3030×11
LMK3-0.66 1500/51500/550.51187608730×3030×11
LMK3-0.66 2000/52000/550.51187608730×3030×11
LMK3-0.66 2500/52500/550.51187608730×3030×11
LMK3-0.66 3000/53000/550.51187608730×3030×11
LMK1-0.66 300/5300/550.5111188011840×4040×12
LMK1-0.66 400/5400/550.5111188011840×4040×12
LMK1-0.66 500/5500/550.5111188011840×4040×12
LMK1-0.66 600/5600/550.5111188011840×4040×12
LMK1-0.66 800/5800/550.5111188011840×4040×12
LMK1-0.66 1000/51000/550.5111188011840×4040×12
LMK1-0.66 1200/51200/550.5111188011840×4040×12
LMK1-0.66 1500/51500/550.5111188011840×4040×12
LMK1-0.66 2000/52000/550.5111188011840×4040×12
LMK1-0.66 2500/52500/550.5111188011840×4040×12
LMK1-0.66 3000/53000/550.5111188011840×4040×12
LMK2-0.66 300/5300/550.5111188011840×4040×12
LMK2-0.66 400/5400/550.5111188011840×4040×12
LMK2-0.66 500/5500/550.5111188011840×4040×12
LMK2-0.66 600/5600/550.5111188011840×4040×12
LMK2-0.66 800/5800/550.5111188011840×4040×12
LMK2-0.66 1000/51000/550.5111188011840×4040×12
LMK2-0.66 1200/51200/550.5111188011840×4040×12
LMK2-0.66 1500/51500/550.5111188011840×4040×12
LMK2-0.66 2000/52000/550.5111188011840×4040×12
LMK2-0.66 2500/52500/550.5111188011840×4040×12
LMK2-0.66 3000/53000/550.5111188011840×4040×12
LMK3-0.66 300/5300/550.5111188011840×4040×12
LMK3-0.66 400/5400/550.5111188011840×4040×12
LMK3-0.66 500/5500/550.5111188011840×4040×12
LMK3-0.66 600/5600/550.5111188011840×4040×12
LMK3-0.66 800/5800/550.5111188011840×4040×12
LMK3-0.66 1000/51000/550.5111188011840×4040×12
LMK3-0.66 1200/51200/550.5111188011840×4040×12
LMK3-0.66 1500/51500/550.5111188011840×4040×12
LMK3-0.66 2000/52000/550.5111188011840×4040×12
LMK3-0.66 2500/52500/550.5111188011840×4040×12
LMK3-0.66 3000/53000/550.5111188011840×4040×12
LMK1-0.66 400/5400/550.51114010014050×5050×12
LMK1-0.66 500/5500/550.51114010014050×5050×12
LMK1-0.66 600/5600/550.51114010014050×5050×12
LMK1-0.66 800/5800/550.51114010014050×5050×12
LMK1-0.66 1000/51000/550.51114010014050×5050×12
LMK1-0.66 1200/51200/550.51114010014050×5050×12
LMK1-0.66 1500/51500/550.51114010014050×5050×12
LMK1-0.66 2000/52000/550.51114010014050×5050×12
LMK1-0.66 2500/52500/550.51114010014050×5050×12
LMK1-0.66 3000/53000/550.51114010014050×5050×12
LMK2-0.66 400/5400/550.51114010014050×5050×12
LMK2-0.66 500/5500/550.51114010014050×5050×12
LMK2-0.66 600/5600/550.51114010014050×5050×12
LMK2-0.66 800/5800/550.51114010014050×5050×12
LMK2-0.66 1000/51000/550.51114010014050×5050×12
LMK2-0.66 1200/51200/550.51114010014050×5050×12
LMK2-0.66 1500/51500/550.51114010014050×5050×12
LMK2-0.66 2000/52000/550.51114010014050×5050×12
LMK2-0.66 2500/52500/550.51114010014050×5050×12
LMK2-0.66 3000/53000/550.51114010014050×5050×12
LMK3-0.66 400/5400/550.51114010014050×5050×12
LMK3-0.66 500/5500/550.51114010014050×5050×12
LMK3-0.66 600/5600/550.51114010014050×5050×12
LMK3-0.66 800/5800/550.51114010014050×5050×12
LMK3-0.66 1000/51000/550.51114010014050×5050×12
LMK3-0.66 1200/51200/550.51114010014050×5050×12
LMK3-0.66 1500/51500/550.51114010014050×5050×12
LMK3-0.66 2000/52000/550.51114010014050×5050×12
LMK3-0.66 2500/52500/550.51114010014050×5050×12
LMK3-0.66 3000/53000/550.51114010014050×5050×12
LMK1-0.66 500/5500/550.51118212018260×6060×12
LMK1-0.66 600/5600/550.51118212018260×6060×12
LMK1-0.66 800/5800/550.51118212018260×6060×12
LMK1-0.66 1000/51000/550.51118212018260×6060×12
LMK1-0.66 1200/51200/550.51118212018260×6060×12
LMK1-0.66 1500/51500/550.51118212018260×6060×12
LMK1-0.66 2000/52000/550.51118212018260×6060×12
LMK1-0.66 2500/52500/550.51118212018260×6060×12
LMK1-0.66 3000/53000/550.51118212018260×6060×12
LMK2-0.66 500/5500/550.51118212018260×6060×12
LMK2-0.66 600/5600/550.51118212018260×6060×12
LMK2-0.66 800/5800/550.51118212018260×6060×12
LMK2-0.66 1000/51000/550.51118212018260×6060×12
LMK2-0.66 1200/51200/550.51118212018260×6060×12
LMK2-0.66 1500/51500/550.51118212018260×6060×12
LMK2-0.66 2000/52000/550.51118212018260×6060×12
LMK2-0.66 2500/52500/550.51118212018260×6060×12
LMK2-0.66 3000/53000/550.51118212018260×6060×12
LMK3-0.66 500/5500/550.51118212018260×6060×12
LMK3-0.66 600/5600/550.51118212018260×6060×12
LMK3-0.66 800/5800/550.51118212018260×6060×12
LMK3-0.66 1000/51000/550.51118212018260×6060×12
LMK3-0.66 1200/51200/550.51118212018260×6060×12
LMK3-0.66 1500/51500/550.51118212018260×6060×12
LMK3-0.66 2000/52000/550.51118212018260×6060×12
LMK3-0.66 2500/52500/550.51118212018260×6060×12
LMK3-0.66 3000/53000/550.51118212018260×6060×12
LMK1-0.66 600/5600/550.51122712022780×8080×12
LMK1-0.66 800/5800/550.51122712022780×8080×12
LMK1-0.66 1000/51000/550.51122712022780×8080×12
LMK1-0.66 1200/51200/550.51122712022780×8080×12
LMK1-0.66 1500/51500/550.51122712022780×8080×12
LMK1-0.66 2000/52000/550.51122712022780×8080×12
LMK1-0.66 2500/52500/550.51122712022780×8080×12
LMK1-0.66 3000/53000/550.51122712022780×8080×12
LMK2-0.66 600/5600/550.51122712022780×8080×12
LMK2-0.66 800/5800/550.51122712022780×8080×12
LMK2-0.66 1000/51000/550.51122712022780×8080×12
LMK2-0.66 1200/51200/550.51122712022780×8080×12
LMK2-0.66 1500/51500/550.51122712022780×8080×12
LMK2-0.66 2000/52000/550.51122712022780×8080×12
LMK2-0.66 2500/52500/550.51122712022780×8080×12
LMK2-0.66 3000/53000/550.51122712022780×8080×12
LMK3-0.66 600/5600/550.51122712022780×8080×12
LMK3-0.66 800/5800/550.51122712022780×8080×12
LMK3-0.66 1000/51000/550.51122712022780×8080×12
LMK3-0.66 1200/51200/550.51122712022780×8080×12
LMK3-0.66 1500/51500/550.51122712022780×8080×12
LMK3-0.66 2000/52000/550.51122712022780×8080×12
LMK3-0.66 2500/52500/550.51122712022780×8080×12
LMK3-0.66 3000/53000/550.51122712022780×8080×12
LMK1-0.66 1000/51000/550.511248120248100×80100×12
LMK1-0.66 1200/51200/550.511248120248100×80100×12
LMK1-0.66 1500/51500/550.511248120248100×80100×12
LMK1-0.66 2000/52000/550.511248120248100×80100×12
LMK1-0.66 2500/52500/550.511248120248100×80100×12
LMK1-0.66 3000/53000/550.511248120248100×80100×12
LMK2-0.66 1000/51000/550.511248120248100×80100×12
LMK2-0.66 1200/51200/550.511248120248100×80100×12
LMK2-0.66 1500/51500/550.511248120248100×80100×12
LMK2-0.66 2000/52000/550.511248120248100×80100×12
LMK2-0.66 2500/52500/550.511248120248100×80100×12
LMK2-0.66 3000/53000/550.511248120248100×80100×12
LMK3-0.66 1000/51000/550.511248120248100×80100×12
LMK3-0.66 1200/51200/550.511248120248100×80100×12
LMK3-0.66 1500/51500/550.511248120248100×80100×12
LMK3-0.66 2000/52000/550.511248120248100×80100×12
LMK3-0.66 2500/52500/550.511248120248100×80100×12
LMK3-0.66 3000/53000/550.511248120248100×80100×12
Dessin technique

Dessin de spécification et d'encombrement

Dessin d'encombrement et de dimensions du BH-0.66 — cliquez sur l'image pour zoomer / afficher l'original.

Présentation du produit

À propos de ce produit

BH-0.66

Le BH-0.66 est un transformateur de courant basse tension d'intérieur de 0,66 kV, utilisé pour abaisser le courant primaire vers un secondaire de 5 A ou 1 A pour le comptage et le contrôle dans les systèmes de distribution basse tension. Son isolation sèche moulé en résine époxy et son corps moulé compact conviennent à l'intérieur des tableaux où l'espace est réduit, et les multiples rapports disponibles permettent à une seule taille de cadre de couvrir plusieurs circuits.

Les classes de précision 0,2, 0,5 et 1,0 sont proposées à 50/60 Hz, avec la charge nominale et les données thermiques de courte durée indiquées sur la plaque signalétique et la fiche technique plutôt que supposées ici. Comme il s'agit d'un transformateur de courant basse tension sans fusibles primaires, le schéma de protection repose sur les dispositifs en amont ; cet appareil ne remplace pas un transformateur moyenne tension à fusibles. Il est conçu pour une installation en intérieur dans les appareillages et armoires de distribution basse tension, et non pour des compartiments extérieurs ou moyenne tension.

Respectez la polarité primaire P1/P2 et les bornes secondaires H1/H2, mettez le secondaire à la terre en un seul point et ne jamais ouvrir le circuit secondaire sous tension. Précisez le rapport, la classe et la puissance secondaire lors de la demande ; les certificats d'essai et les délais de livraison sont disponibles sur demande.

Autres modèles de cette série

Même famille de produits, caractéristiques différentes — à comparer avant de spécifier.

Transformateur de courant CGIS1911 pour appareillage à isolation gazeuse CGIS
35kV
Transformateur de courant50/60Hz

CGIS1911

Transformateur de courant CGIS1911 pour appareillage à isolation gazeuse CGIS

Transformateur de courant intérieur à résine époxy coulée conçu pour appareillage à isolation gazeuse CGIS, avec plusieurs options de classe de précision, de charge nominale et de courant primaire.

Classe de précisionSur demande
Type d'isolementRésine époxy coulée (sec)
Charge nominaleSur demande
Voir les spécifications
Transformateur de courant CGIS1775 pour appareillage à isolation gazeuse CGIS
35kV
Transformateur de courant50/60Hz

CGIS1775

Transformateur de courant CGIS1775 pour appareillage à isolation gazeuse CGIS

Transformateur de courant intérieur à résine époxy coulée conçu pour appareillage à isolation gazeuse CGIS, avec plusieurs options de classe de précision, de charge nominale et de courant primaire.

Classe de précisionSur demande
Type d'isolementRésine époxy coulée (sec)
Charge nominaleSur demande
Voir les spécifications
Transformateur de courant CGIS1780 I pour appareillage de commutation isolé au gaz CGIS
35kV
Transformateur de courant50/60Hz

CGIS1780-I

Transformateur de courant CGIS1780 I pour appareillage de commutation isolé au gaz CGIS

Transformateur de courant intérieur à coulée de résine époxy conçu pour l'appareillage de commutation isolé au gaz CGIS, avec plusieurs options de classe de précision, de charge nominale et de courant primaire.

Classe de précisionSur demande
Type d'isolementRésine époxy coulée (sec)
Charge nominaleSur demande
Voir les spécifications