BH-0.66 Indoor Low Voltage Current Transformer 0.66kV is designed for metering and protection in power systems. Key ratings: primary voltage 0.66kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
BH-0.66 is a low voltage current transformer for indoor use, suitable for current measurement and protection in LV distribution systems.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 61869 / GB/T 20840 |
| Model Code | BH-0.66 | Factory nameplate marking |
| Primary Voltage | 0.66kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A/1A | Ratio check at rated frequency |
| Accuracy Class | 0.2/0.5/1.0 | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | IEC 61869 / GB/T 20840 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary conductor through the window. Secondary terminals are 1S1 and 1S2 for the main winding; if dual ratio, use appropriate taps. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869 for terminal markings and safety.
Compliant with: IEC 61869 / GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the rated voltage of BH-0.66?
A: The rated voltage is 0.66kV.
Q: What accuracy classes are available?
A: Accuracy classes available are 0.2, 0.5, and 1.0.
Q: Can it be used outdoors?
A: No, it is designed for indoor use only.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Model | Rated current ratio (A) | Rated output (VA) | Accuracy class | Primary turns | Turns through core | Overall dimensions | Aperture dimensions (W×H) | Mounting dimensions (W×H) | ||
|---|---|---|---|---|---|---|---|---|---|---|
| W | D | H | ||||||||
| LMK1-0.66 30/5 | 30/5 | 1 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 40/5 | 40/5 | 1 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 50/5 | 50/5 | 1.5 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 60/5 | 60/5 | 2.5 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 75/5 | 75/5 | 2.5 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 100/5 | 100/5 | 2.5 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 150/5 | 150/5 | 3.75 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 200/5 | 200/5 | 5 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 250/5 | 250/5 | 5 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 300/5 | 300/5 | 5 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 400/5 | 400/5 | 5 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK1-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 78 | 52 | 78 | 30×30 | 30×11 |
| LMK2-0.66 100/5 | 100/5 | 2.5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK2-0.66 150/5 | 150/5 | 3.75 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK2-0.66 200/5 | 200/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK2-0.66 250/5 | 250/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK2-0.66 300/5 | 300/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK2-0.66 400/5 | 400/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK2-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK2-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK2-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK2-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK3-0.66 100/5 | 100/5 | 2.5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK3-0.66 150/5 | 150/5 | 3.75 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK3-0.66 200/5 | 200/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK3-0.66 250/5 | 250/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK3-0.66 300/5 | 300/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK3-0.66 400/5 | 400/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK3-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK3-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK3-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK3-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 82 | 62 | 82 | 30×30 | 30×11 |
| LMK1-0.66 150/5 | 150/5 | 2.5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 200/5 | 200/5 | 3.75 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 250/5 | 250/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 300/5 | 300/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 400/5 | 400/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 150/5 | 150/5 | 2.5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 200/5 | 200/5 | 3.75 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 250/5 | 250/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 300/5 | 300/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 400/5 | 400/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK2-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 150/5 | 150/5 | 2.5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 200/5 | 200/5 | 3.75 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 250/5 | 250/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 300/5 | 300/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 400/5 | 400/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK3-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 87 | 60 | 87 | 30×30 | 30×11 |
| LMK1-0.66 300/5 | 300/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK1-0.66 400/5 | 400/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK1-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK1-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK1-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK1-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK1-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK1-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK1-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK1-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK1-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK2-0.66 300/5 | 300/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK2-0.66 400/5 | 400/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK2-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK2-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK2-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK2-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK2-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK2-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK2-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK2-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK2-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK3-0.66 300/5 | 300/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK3-0.66 400/5 | 400/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK3-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK3-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK3-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK3-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK3-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK3-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK3-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK3-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK3-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 118 | 80 | 118 | 40×40 | 40×12 |
| LMK1-0.66 400/5 | 400/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK1-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK1-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK1-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK1-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK1-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK1-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK1-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK1-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK1-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK2-0.66 400/5 | 400/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK2-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK2-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK2-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK2-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK2-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK2-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK2-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK2-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK2-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK3-0.66 400/5 | 400/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK3-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK3-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK3-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK3-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK3-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK3-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK3-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK3-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK3-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 140 | 100 | 140 | 50×50 | 50×12 |
| LMK1-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK1-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK1-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK1-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK1-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK1-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK1-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK1-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK1-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK2-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK2-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK2-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK2-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK2-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK2-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK2-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK2-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK2-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK3-0.66 500/5 | 500/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK3-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK3-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK3-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK3-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK3-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK3-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK3-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK3-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 182 | 120 | 182 | 60×60 | 60×12 |
| LMK1-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK1-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK1-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK1-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK1-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK1-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK1-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK1-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK2-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK2-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK2-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK2-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK2-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK2-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK2-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK2-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK3-0.66 600/5 | 600/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK3-0.66 800/5 | 800/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK3-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK3-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK3-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK3-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK3-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK3-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 227 | 120 | 227 | 80×80 | 80×12 |
| LMK1-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK1-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK1-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK1-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK1-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK1-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK2-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK2-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK2-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK2-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK2-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK2-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK3-0.66 1000/5 | 1000/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK3-0.66 1200/5 | 1200/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK3-0.66 1500/5 | 1500/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK3-0.66 2000/5 | 2000/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK3-0.66 2500/5 | 2500/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
| LMK3-0.66 3000/5 | 3000/5 | 5 | 0.5 | 1 | 1 | 248 | 120 | 248 | 100×80 | 100×12 |
Dimension & outline drawing of BH-0.66 — click image to zoom / view original.
The BH-0.66 is an indoor low-voltage current transformer rated 0.66kV, used to step primary current down to a 5A or 1A secondary for metering and control in low-voltage distribution systems. Its dry epoxy resin insulation and compact cast body suit panel interiors where space is tight, and the multiple available ratios allow one frame size to cover several circuits.
Accuracy classes 0.2, 0.5 and 1.0 are offered at 50/60Hz, with rated burden and short-time thermal data stated on the nameplate and datasheet rather than assumed here. Because it is a low-voltage CT without primary fuses, the protection scheme relies on upstream devices; this unit is not a substitute for a fused medium-voltage transformer. It is designed for indoor installation in low-voltage switchgear and distribution cabinets, not for outdoor or medium-voltage compartments.
Observe the P1/P2 primary polarity and H1/H2 secondary terminals, earth the secondary at one point, and never open-circuit the secondary while energized. Specify ratio, class and secondary output at inquiry; [On Request] covers test certificates and delivery schedules.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.