Transformator arus resin epoksi cor satu fasa dalam ruangan, sesuai dengan standar GB/T20840.1/2 dan IEC61869-1/2; tingkat isolasi nominal 12/42/75kV, frekuensi nominal 50/60Hz, arus nominal sekunder 5A atau 1A. Tersedia empat tipe struktural opsional: 2s konvensional, 2s rasio ganda dengan penyadapan sekunder, 4s konvensional, 4s rasio ganda dengan penyadapan sekunder. Arus primer opsional mencakup 20–1250A; keluaran nominal kelas akurasi: 0,2(S):10VA, 0,5(S):10VA, 5(10)P10:15VA, 5(10)P15:15VA; rentang arus tahan termal waktu singkat 7,5–100kA, rentang arus tahan dinamis nominal 25–160kA; berat sesuai struktur: 23kg, 24,5kg, 37kg; suhu lingkungan operasi: -5°C hingga +40°C.
Transformator arus 12kV dalam ruangan untuk switchgear MV, pengukuran, dan proteksi. Cocok untuk sistem 10kV dengan 50/60Hz.
| Parameter | Spesifikasi | Verifikasi |
|---|---|---|
| Jenis Produk | Transformator Arus | [Atas Permintaan] |
| Kode Model | LZZBJ9-12-150b-2s-4s | Penandaan pabrik |
| Tegangan Primer | 12kV | Uji tegangan nominal (IEC 61869-1/3) |
| Arus Sekunder | 5A/1A | Pemeriksaan rasio pada frekuensi nominal |
| Kelas Akurasi | [On Request] | Uji akurasi (IEC 61869-2 / IEEE C57.13) |
| Beban Nominal | [On Request] | Uji beban pada VA nominal |
| Jenis Isolasi | Dry Epoxy Resin | Uji dielektrik sesuai standar |
| Tingkat Isolasi (BIL) | 12/42/75kV | Ketahanan frekuensi daya & impuls petir |
| Standar | [On Request] | Tersertifikasi sesuai standar yang tercantum |
| Frekuensi | 50/60Hz | Sesuai IEC 61869-1 |
| Lingkungan | Ambient: -5℃~+40℃ | Sesuai batas lembar data |
Ideal Untuk
Tidak Direkomendasikan Untuk
Untuk CT: hubungkan primer melalui bushing; terminal sekunder 1S1/1S2 untuk pengukuran, 2S1/2S2 untuk proteksi (jika rasio ganda). Jangan pernah membuka rangkaian sekunder CT saat bertegangan - tegangan berbahaya. Tanahkan rangkaian sekunder pada satu titik saja. Ikuti penandaan terminal IEC 61869-2. ⚠️ Safety: Follow the nameplate terminal diagram and ground the secondary winding at one point.
Sesuai dengan: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
T: Apa tingkat isolasi CT ini?
J: Sistem 12kV; tahan tegangan frekuensi daya 42kV; tahan impuls petir 75kV puncak.
T: Apakah CT ini dapat digunakan di luar ruangan?
J: Tidak, alat ini dirancang hanya untuk penggunaan dalam ruangan.
T: Kelas akurasi apa saja yang tersedia?
J: 0,2S, 0,5S untuk pengukuran; 5P10, 5P15 untuk proteksi.
Bidang yang hilang ditandai [Atas Permintaan] — tidak pernah direkayasa. Baris verifikasi M2/M5/M6 mengikuti konvensi IEC 61869 / IEEE C57.13.
| Rated primary current (A) | Accuracy classCombined | Accuracy class & rated output (VA) | Short-time thermal current (kA/s) | Rated dynamic current (kA) | Weight (kg) |
|---|---|---|---|---|---|
| 20-200 | 0.2(5)/0.5(5) | 10 10 15 15 | 150/1 | 375/1 | — |
| 300-400 | 0.2(5)/5P10 | 10 10 15 15 | 31.5 | 80 | — |
| 500 | 0.2(5)/5P15 | 10 10 15 15 | 31.5 | 80 | — |
| 600-800 | 0.2(5)/5P15 | 10 10 15 15 | 80 | 160 | — |
| 1000-1250 | 0.2(5)/5P20 | 10 10 15 15 | 100 | 160 | — |

Gambar dimensi & garis besar LZZBJ9-12-150b-2s-4s — klik gambar untuk memperbesar / melihat asli.
LZZBJ9-12/150b/2s(4s) is a 12 kV indoor epoxy-cast current transformer offered with either two or four secondary cores from the same cast body. It is the general-purpose 12 kV unit in the range: 20 A to 1250 A primary, 5 A or 1 A secondary, for metering and protection in medium-voltage switchgear.
Accuracy depends on the ratio band. From 20 A to 200 A the unit is specified as 0.2(5)/0.5(5) with 10 VA, 10 VA, 15 VA and 15 VA across its cores, and short-time thermal current of 150 times primary for 1 s. From 300 A upward the protection core moves to 5P10, 5P15 or 5P20 and the thermal rating is stated in absolute terms, 31.5 kA at 300–500 A rising to 100 kA at 1000–1250 A.
Because the same frame covers both the 0.2(5) small-ratio band and the 5P20 high-ratio band, the model is often used where a panel family needs one footprint across feeders of different rating. Specify the core count (2s or 4s) explicitly: the electrical data is shared, but the terminal arrangement and wiring space differ.
Keluarga produk sama, rating berbeda — bandingkan sebelum menentukan spesifikasi.
Transformator Arus Resin Epoksi Cor Satu Fasa Dalam Ruangan
Transformator arus resin epoksi cor satu fasa dalam ruangan yang sesuai dengan standar GB/T20840.1/2 dan IEC61869-1/2, tingkat isolasi 12/42/75kV, frekuensi nominal 50/60Hz, arus nominal sekunder 5A atau 1A. Jenis struktur opsional: konvensional 2s, konvensional 4s, rasio ganda 4s dengan penyadapan sekunder; arus primer opsional mencakup 20–3150A. Keluaran nominal kelas akurasi bervariasi menurut struktur: 10VA/15VA/20VA/30VA/50VA untuk berbagai tingkat akurasi; arus termal jangka pendek berkisar 11,25–100 kA, arus tahan dinamis nominal berkisar 28–160 kA; berat yang sesuai: 26kg (2s), 39kg (4s / rasio ganda 4s); suhu operasi lingkungan -5°C hingga +40°C.
Transformator Arus Resin Epoksi Cor Satu Fasa Dalam Ruangan
Transformator arus resin epoksi cor satu fasa dalam ruangan yang sesuai dengan standar GB/T20840.1/2 dan IEC61869-1/2, tingkat isolasi 12/42/75kV, frekuensi nominal 50/60Hz, arus nominal sekunder 5A atau 1A. Jenis struktur opsional: konvensional 2s, konvensional 4s, rasio ganda 2s dengan penyadapan sekunder; arus primer opsional mencakup 20–3150A. Keluaran nominal kelas akurasi berbeda menurut struktur: 10VA/15VA/20VA/30VA untuk kelas akurasi berbeda; arus termal jangka pendek berkisar 12–100 kA, arus tahan dinamis nominal berkisar 30–160 kA; berat sesuai: 32kg (2s & rasio ganda 2s), 42kg (4s); suhu operasi lingkungan -5°C hingga +40°C.
Transformator Arus Cetakan Epoksi Satu Fasa Dalam Ruangan 12kV
Transformator arus (CT) satu fasa resin epoksi cor dalam ruangan, sesuai GB/T20840.1/2 & IEC61869-1/2, tingkat isolasi 12/42/75kV, 50/60Hz, arus sekunder 5A/1A. Rentang arus primer opsional: 20-200A, 300A, 400A, 500-600A, 800-1000A, 1200-3150A; berbagai kombinasi kelas akurasi pengukuran dan proteksi, parameter tahan termal/dinamis yang sesuai untuk setiap rentang, berat bersih 62kg, suhu operasi -5°C hingga +40°C.