Transformator arus (CT) satu fasa resin epoksi cor dalam ruangan, sesuai GB/T20840.1/2 & IEC61869-1/2, tingkat isolasi 12/42/75kV, 50/60Hz, arus sekunder 5A/1A. Rentang arus primer opsional: 20-200A, 300A, 400A, 500-600A, 800-1000A, 1200-3150A; berbagai kombinasi kelas akurasi pengukuran dan proteksi, parameter tahan termal/dinamis yang sesuai untuk setiap rentang, berat bersih 62kg, suhu operasi -5°C hingga +40°C.
CT cetakan epoksi dalam ruangan untuk sistem 12kV, cocok untuk pengukuran dan proteksi pada switchgear MV.
| Parameter | Spesifikasi | Verifikasi |
|---|---|---|
| Jenis Produk | Transformator Arus | IEC 61869 / GB/T 20840 |
| Kode Model | LZZBJ9-12-195b-4s | Penandaan pabrik |
| Tegangan Primer | 0.5kV | Uji tegangan nominal (IEC 61869-1/3) |
| Arus Sekunder | [On Request] | Pemeriksaan rasio pada frekuensi nominal |
| Kelas Akurasi | 0.5/1.0/3.0 | Uji akurasi (IEC 61869-2 / IEEE C57.13) |
| Beban Nominal | [On Request] | Uji beban pada VA nominal |
| Jenis Isolasi | Dry Epoxy Resin | Uji dielektrik sesuai standar |
| Tingkat Isolasi (BIL) | [On Request] | Ketahanan frekuensi daya & impuls petir |
| Standar | IEC 61869 / GB/T 20840 | Tersertifikasi sesuai standar yang tercantum |
| Frekuensi | 50/60Hz | Sesuai IEC 61869-1 |
| Lingkungan | [On Request] | Sesuai batas lembar data |
Ideal Untuk
Tidak Direkomendasikan Untuk
Untuk CT: Hubungkan primer melalui bushing. Terminal sekunder: 1S1 dan 1S2 untuk pengukuran, 2S1 dan 2S2 untuk proteksi. Jangan pernah membuka rangkaian sekunder saat bertegangan - tegangan berbahaya. Tanahkan belitan sekunder pada satu titik. Ikuti penandaan terminal IEC 61869-2. ⚠️ Safety: Follow the nameplate terminal diagram and ground the secondary winding at one point.
Sesuai dengan: IEC 61869 / GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
T: Apa tingkat isolasi CT ini?
J: Tingkat isolasi adalah 12/42/75kV, artinya tegangan sistem 12kV, tahan tegangan frekuensi daya 42kV, dan tahan impuls petir 75kV.
T: Kelas akurasi apa yang tersedia?
J: Kelas akurasi meliputi 0,5, 1,0, dan 3,0, cocok untuk pengukuran dan proteksi.
T: Apakah CT ini dapat digunakan di luar ruangan?
J: Tidak, perangkat ini dirancang hanya untuk penggunaan dalam ruangan karena cetakan epoksi dan konstruksi dalam ruangannya.
Bidang yang hilang ditandai [Atas Permintaan] — tidak pernah direkayasa. Baris verifikasi M2/M5/M6 mengikuti konvensi IEC 61869 / IEEE C57.13.
| Rated primary current (A) | Accuracy classCombined | Accuracy class & rated output (VA) COSφ=0.8 | Short-time thermal current (kA/S) | Rated dynamic current (kA) | Weight (kg) |
|---|---|---|---|---|---|
| 200-200 | 0.2(5) 0.2(5) 5P/5P 5P/5P | 20 20 25 20 15 | 150 15 | 150 375 | 82 |
| 300 | 0.2(5) 0.2(5) 5P/5P 5P/5P | 20 20 25 20 15 | 31.5 45 | 80 112.5 | 82 |
| 400 | 0.2(5) 0.2(5) 5P/5P 5P/5P | 20 20 25 20 15 | 45 63 | 112.5 130 | 82 |
| 500-600 | 0.2(5) 0.2(5) 5P/5P 5P/5P | 20 20 25 20 15 | 63 80 | 130 160 | 82 |
| 800-1000 | 0.2(5) 0.2(5) 5P/5P 5P/5P | 30 30 40 30 20 | 80 100 | 160 200 | 82 |
| 1200-3150 | 0.2(5) 0.2(5) 5P/5P 5P/5P | 30 30 40 30 20 | 100 | 160 | 82 |

Gambar dimensi & garis besar LZZBJ9-12-195b-4s — klik gambar untuk memperbesar / melihat asli.
LZZBJ9-12/195b/4s is the 12 kV four-core model built for the 200–3150 A band, where the primary bar is large and the secondary wiring is dense. The cast body weighs 82 kg, roughly three times the 26 kg of the 175b frame, because the larger window and the four-core winding package need more epoxy and more iron.
Its datasheet lists 20/20/25/20/15 VA across the cores, with accuracy combinations of 0.2(5), 0.2(5), 5P and 5P. From 800 A upward the outputs rise to 30/30/40/30/20 VA, and short-time thermal current reaches 100 kA with a 160 kA dynamic rating at 1200–3150 A. The four cores are typically split two for metering and two for protection.
This model shares its electrical datasheet with LZZBJ9-12/198b/4s and LZZBJ9-12/225b/4s; the three are published together as dimensional variants of one design. Order by the frame that fits the panel, and confirm which of the three bodies the drawing specifies before releasing the purchase order.
Keluarga produk sama, rating berbeda — bandingkan sebelum menentukan spesifikasi.
Transformator Arus Cetakan Epoksi Satu Fasa Dalam Ruangan 12kV
Transformator arus resin epoksi cor satu fasa dalam ruangan, sesuai dengan GB/T20840.1/2 & IEC61869-1/2, tingkat isolasi 12/42/75kV, 50/60Hz, arus sekunder 5A/1A. Rentang arus primer opsional: 20-200A, 300-400A, 500-600A, 800-1000A, 1200-1250A, 1500-3150A; kombinasi akurasi beragam untuk pengukuran dan proteksi, pencocokan parameter tahan independen, berat bersih 78kg, suhu operasi -5°C hingga +40°C.
Transformator Arus Cetakan Epoksi Satu Fasa Dalam Ruangan 12kV
Transformator arus resin epoksi cor satu fasa dalam ruangan, sesuai dengan GB/T20840.1/2 & IEC61869-1/2, tingkat isolasi 12/42/75kV, 50/60Hz, arus sekunder 5A/1A. Rentang arus primer opsional: 20-200A, 300-400A, 500-600A, 800-1000A, 1200-1250A, 1500-3150A; opsi keluaran nominal lebih kaya untuk belitan proteksi, berat bersih 80kg, suhu operasi -5°C hingga +40°C.
Transformator Arus Resin Epoksi Cor Satu Fasa Dalam Ruangan, 12kV
Transformator arus resin epoksi cor satu fasa dalam ruangan yang sesuai dengan standar GB/T20840.1/2 dan IEC61869-1/2. Tingkat isolasi: 12/42/75kV, frekuensi 50/60Hz, arus sekunder 5A atau 1A. Rentang arus primer opsional: 5-100A、150A、200-300A、400-600A、800-1200A、1500-2500A. Berbagai kombinasi kelas akurasi termasuk 0,2S/0,5S dan kelas proteksi, dengan arus tahan termal & dinamis jangka pendek yang sesuai untuk setiap rentang, cocok untuk pengukuran dan proteksi relai pada kabinet switchgear tegangan menengah. Suhu operasi lingkungan: -5°C hingga +40°C, berat bersih 25kg.