Transformator arus resin epoksi cor satu fasa dalam ruangan yang sesuai dengan standar GB/T20840.1/2 dan IEC61869-1/2; tingkat isolasi nominal 24/65/125kV, frekuensi nominal 50/60Hz, arus sekunder nominal 5A atau 1A. Arus primer opsional mencakup 20–2000A; keluaran nominal kelas akurasi: 10VA untuk 0,2(S)/0,5(S), 15VA untuk 10P15; arus termal jangka pendek berkisar 31,5–100kA, arus tahan dinamis nominal berkisar 80–160kA; berat produk: 36,5kg; suhu operasi lingkungan -5°C hingga +40°C.
Transformator arus resin epoksi dalam ruangan untuk sistem 12kV, cocok untuk pengukuran dan proteksi pada switchgear MV.
| Parameter | Spesifikasi | Verifikasi |
|---|---|---|
| Jenis Produk | Transformator Arus | [Atas Permintaan] |
| Kode Model | LZZBJ9-20-180b-3 | Penandaan pabrik |
| Tegangan Primer | 20kV | Uji tegangan nominal (IEC 61869-1/3) |
| Arus Sekunder | 5A/1A | Pemeriksaan rasio pada frekuensi nominal |
| Kelas Akurasi | [On Request] | Uji akurasi (IEC 61869-2 / IEEE C57.13) |
| Beban Nominal | [On Request] | Uji beban pada VA nominal |
| Jenis Isolasi | Dry Epoxy Resin | Uji dielektrik sesuai standar |
| Tingkat Isolasi (BIL) | 24/65/125kV | Ketahanan frekuensi daya & impuls petir |
| Standar | [On Request] | Tersertifikasi sesuai standar yang tercantum |
| Frekuensi | 50/60Hz | Sesuai IEC 61869-1 |
| Lingkungan | Ambient: -5℃~+40℃ | Sesuai batas lembar data |
Ideal Untuk
Tidak Direkomendasikan Untuk
Untuk CT: Hubungkan primer secara seri dengan saluran. Terminal sekunder: 1S1-1S2 untuk pengukuran, 2S1-2S2 untuk proteksi. Jangan pernah membuka rangkaian sekunder CT saat bertegangan - tegangan berbahaya. Tanahkan belitan sekunder pada satu titik. ⚠️ Safety: Follow the nameplate terminal diagram and ground the secondary winding at one point.
Sesuai dengan: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
T: Apa tingkat isolasinya?
J: Tingkat isolasi adalah 12/42/75kV, yang berarti sistem 12kV, tahanan frekuensi daya 42kV, tahanan impuls petir 75kV.
T: Apa saja arus sekunder yang tersedia?
J: Arus sekunder adalah 5A atau 1A, dapat dipilih.
T: Apakah cocok untuk penggunaan luar ruangan?
J: Tidak, perangkat ini dirancang hanya untuk penggunaan dalam ruangan.
Bidang yang hilang ditandai [Atas Permintaan] — tidak pernah direkayasa. Baris verifikasi M2/M5/M6 mengikuti konvensi IEC 61869 / IEEE C57.13.
| Rated primary current I1n (A) | Accuracy classCombined | 0.2(S) | 0.5(S) | 1J/P15 | Short-time thermal current Ith (kA/S) | Rated dynamic current Idyn (kA) | Weight (kg) |
|---|---|---|---|---|---|---|---|
| 20-200 | 0.2(S)/0.2(S) | 10 | 10 | 15 | 150 I1n | 375 I1n | 36.5 |
| 300 | 0.2(S)/0.5(S) | 10 | 10 | 15 | 31.5 | 80 | 36.5 |
| 400-500 | 0.2(S)/0.5(S) | 10 | 10 | 15 | 45 | 110 | 36.5 |
| 600-800 | 0.5(S)/10P | 10 | 10 | 15 | 63 | 130 | 36.5 |
| 1600-2000 | 0.5(S)/10P | 10 | 15 | 15 | 100 | 160 | 36.5 |

Gambar dimensi & garis besar LZZBJ9-20-180b-3 — klik gambar untuk memperbesar / melihat asli.
LZZBJ9-20/180b/3 is the 20 kV model, with three secondary cores and a 36.5 kg cast body. It covers 20 A to 2000 A primary and is specified for 20 kV switchgear where a 12 kV frame would be under-insulated and a 24 kV frame oversized.
Accuracy is listed as 0.2(S)/0.2(S) in the 20–200 A band, 0.2(S)/0.5(S) from 300 A to 500 A, and 0.5(S)/10P from 600 A to 2000 A, with 10 VA and 15 VA outputs. Short-time thermal current is 150 times primary at the bottom of the range and rises to 100 kA with a 160 kA dynamic rating at 1600–2000 A.
The three-core arrangement suits a panel that needs one metering circuit and two protection circuits but does not have room for a four-core casting. Note that the accuracy class shifts from 0.2(S) to 0.5(S) above 500 A in the published table, so revenue metering at high ratios should be checked against the actual ratio band.
Keluarga produk sama, rating berbeda — bandingkan sebelum menentukan spesifikasi.
Transformator Arus Resin Epoksi Cor Satu Fasa Dalam Ruangan
Transformator arus resin epoksi cor satu fasa dalam ruangan yang sesuai dengan standar GB/T20840.1/2 dan IEC61869-1/2; tingkat isolasi nominal 24/65/125kV, frekuensi nominal 50/60Hz, arus sekunder nominal 5A atau 1A. Dua struktur opsional: 2s dan 4s; rentang arus primer opsional 20-2500A. Untuk tipe 2s: keluaran nominal 10-20VA pada berbagai kelas akurasi, berat 36kg; untuk tipe 4s: keluaran nominal 15-20VA pada berbagai kelas akurasi, berat 50kg; arus termal jangka pendek: 31,5-100kA, arus tahan dinamis nominal: 80-160kA; suhu operasi lingkungan -5°C hingga +40°C.
Transformator Arus Resin Epoksi Cor Satu Fasa Dalam Ruangan
Transformator arus resin epoksi cor satu fasa dalam ruangan yang sesuai dengan standar GB/T20840.1/2 dan IEC61869-1/2; tingkat isolasi nominal 24/65/125kV, frekuensi nominal 50/60Hz, arus sekunder nominal 5A atau 1A. Dua struktur opsional: 2s dan 4s, rentang arus primer opsional 20-3150A. Model 2s memiliki berat 43kg dengan keluaran nominal 15-30VA pada berbagai kelas akurasi; model 4s memiliki berat 70kg dengan keluaran nominal 15-30VA pada berbagai kelas akurasi; arus termal jangka pendek berkisar 31,5-100kA, arus tahan dinamis nominal berkisar 80-160kA; suhu operasi lingkungan -5°C hingga +40°C.
Transformator Arus Resin Epoksi Cor Satu Fasa Dalam Ruangan
Transformator arus resin epoksi cor satu fasa dalam ruangan yang sesuai dengan standar GB/T20840.1/2 dan IEC61869-1/2; tingkat isolasi nominal 40,5/95/185kV, frekuensi nominal 50/60Hz, arus sekunder nominal 5A atau 1A. Arus primer opsional mencakup 20–3150A; keluaran nominal kelas akurasi: 30VA(0,2S/0,5S), 30VA(0,5), 50VA(5P10), 40VA(5P15), 30VA(5P20); arus tahan termal waktu singkat berkisar 4–31,5kA, arus tahan dinamis nominal berkisar 10–130kA; berat produk: 112kg; suhu operasi lingkungan -5°C hingga +40°C.