Transformator arus resin epoksi cor satu fasa dalam ruangan sesuai standar GB/T20840.1/2 dan IEC61869-1/2; tingkat isolasi nominal 40,5/95/185kV, frekuensi nominal 50/60Hz, arus sekunder nominal 5A atau 1A. Arus primer opsional mencakup 20–3150A; keluaran nominal kelas akurasi: 30VA (0,2S/0,5S), 30VA (0,5), 30VA (5P20), 25VA (5P25), 20VA (5P30); arus tahan termal waktu singkat berkisar 25–150kA, arus tahan dinamis nominal berkisar 63–375kA; berat produk: 140kg; suhu operasi lingkungan -5°C hingga +40°C.
Transformator arus kelas 35kV dalam ruangan untuk switchgear tegangan menengah, pengukuran, dan proteksi. Cocok untuk sistem 10kV dengan sekunder 5A/1A.
| Parameter | Spesifikasi | Verifikasi |
|---|---|---|
| Jenis Produk | Transformator Arus | [Atas Permintaan] |
| Kode Model | LZZBJ9-35D1 | Penandaan pabrik |
| Tegangan Primer | 35kV | Uji tegangan nominal (IEC 61869-1/3) |
| Arus Sekunder | 5A/1A | Pemeriksaan rasio pada frekuensi nominal |
| Kelas Akurasi | [On Request] | Uji akurasi (IEC 61869-2 / IEEE C57.13) |
| Beban Nominal | [On Request] | Uji beban pada VA nominal |
| Jenis Isolasi | Dry Epoxy Resin | Uji dielektrik sesuai standar |
| Tingkat Isolasi (BIL) | 40.5/95/185kV | Ketahanan frekuensi daya & impuls petir |
| Standar | [On Request] | Tersertifikasi sesuai standar yang tercantum |
| Frekuensi | 50/60Hz | Sesuai IEC 61869-1 |
| Lingkungan | Ambient: -5℃~+40℃ | Sesuai batas lembar data |
Ideal Untuk
Tidak Direkomendasikan Untuk
Untuk CT: hubungkan primer melalui bushing; terminal sekunder 1S1/1S2 untuk pengukuran, 2S1-2S2 untuk proteksi. Jangan pernah membuka rangkaian sekunder CT saat bertegangan - tegangan berbahaya. Tanahkan rangkaian sekunder pada satu titik saja. Ikuti penandaan terminal IEC 61869-2. ⚠️ Safety: Follow the nameplate terminal diagram and ground the secondary winding at one point.
Sesuai dengan: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
T: Apa tingkat isolasi CT ini?
J: Tingkat isolasinya adalah 12/42/75kV, yang berarti tegangan sistem 12kV, tahan tegangan frekuensi daya 42kV, impuls petir 75kV.
T: Apakah CT ini dapat digunakan untuk pengukuran dan proteksi sekaligus?
J: Ya, CT ini menawarkan berbagai kelas akurasi (0,2S/0,5S untuk pengukuran, 5P20/5P25/5P30 untuk proteksi) dengan belitan sekunder terpisah.
T: Berapa rating arus primer maksimum?
J: Arus primer opsional mencakup 20–3150A, dengan arus tahan termal waktu singkat hingga 150kA.
Bidang yang hilang ditandai [Atas Permintaan] — tidak pernah direkayasa. Baris verifikasi M2/M5/M6 mengikuti konvensi IEC 61869 / IEEE C57.13.
| Rated primary current I1n (A) | Accuracy classCombined | 0.2(S)/0.5(S) | 0.5 | 5P20 | 5P25 | 5P30 | Short-time thermal current Ith (kA/S) | Rated dynamic current Idyn (kA) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|
| 20-100 | 0.2(S)/5P, 0.5(S)/5P, 0.2(S)/5P/5P, 0.2(S)/5P/5P/5P | 30 | 30 | 30 | 25 | 20 | 150 I1n | 375 I1n | 140 |
| 150 | 0.2(S)/5P, 0.5(S)/5P, 0.2(S)/5P/5P, 0.2(S)/5P/5P/5P | 30 | 30 | 30 | 25 | 20 | 25 | 63 | 140 |
| 200-250 | 0.2(S)/5P, 0.5(S)/5P, 0.2(S)/5P/5P, 0.2(S)/5P/5P/5P | 30 | 30 | 30 | 25 | 20 | 31.5 | 80 | 140 |
| 300-500 | 0.2(S)/5P, 0.5(S)/5P, 0.2(S)/5P/5P, 0.2(S)/5P/5P/5P | 30 | 30 | 30 | 25 | 20 | 31.5 | 80 | 140 |
| 600-800 | 0.2(S)/5P, 0.5(S)/5P, 0.2(S)/5P/5P, 0.2(S)/5P/5P/5P | 30 | 30 | 30 | 25 | 20 | 31.5 | 80 | 140 |
| 1000-3150 | 0.2(S)/5P, 0.5(S)/5P, 0.2(S)/5P/5P, 0.2(S)/5P/5P/5P | 30 | 30 | 30 | 25 | 20 | 31.5 | 80 | 140 |

Gambar dimensi & garis besar LZZBJ9-35D1 — klik gambar untuk memperbesar / melihat asli.
LZZBJ9-35D1 is the heaviest and most capable 35 kV frame in the family: 140 kg, 20 A to 3150 A, and metering cores rated 30 VA. The D1 casting carries four selectable core arrangements, from a single metering-plus-protection pair up to three protection cores alongside the metering core.
Its accuracy string is 0.2(S)/5P, 0.5(S)/5P, 0.2(S)/5P/5P or 0.2(S)/5P/5P/5P, with 30 VA on the metering core and 25–30 VA on the protection cores. Short-time thermal current is 150 times primary for 1 s at 20–100 A, then 25 kA, 31.5 kA and 31.5 kA with 63–80 kA dynamic ratings up to 3150 A.
Choose the D1 when a 35 kV feeder needs three independent protection zones plus revenue metering in one window, or when the connected burden exceeds the 10 VA of the lighter frames. The mass means it is normally lifted into place rather than hand-mounted, and the larger window requires the panel drawing to be checked before ordering.
Keluarga produk sama, rating berbeda — bandingkan sebelum menentukan spesifikasi.
Transformator Arus Resin Epoksi Cor Satu Fasa Dalam Ruangan
Transformator arus resin epoksi cor satu fasa dalam ruangan yang sesuai dengan standar GB/T20840.1/2 dan IEC61869-1/2; tingkat isolasi nominal 40,5/95/185kV, frekuensi nominal 50/60Hz, arus sekunder nominal 5A atau 1A. Arus primer opsional mencakup 20–3150A dengan kelas akurasi dan nilai daya nominal yang sama dengan seri; arus termal jangka pendek berkisar 4–31,5kA, arus tahan dinamis nominal berkisar 10–130kA; berat produk: 78kg; suhu operasi lingkungan -5°C hingga +40°C.
Transformator Arus Resin Epoksi Cor Satu Fasa Dalam Ruangan
Transformator arus resin epoksi cor satu fasa dalam ruangan yang sesuai dengan standar GB/T20840.1/2 dan IEC61869-1/2; tingkat isolasi nominal 40,5/95/185kV, frekuensi nominal 50/60Hz, arus sekunder nominal 5A atau 1A. Arus primer opsional mencakup 20–3150A; keluaran nominal kelas akurasi: 10VA(0,2S/0,5S), 30VA(0,5), 30VA(5P10), 20VA(5P15), 15VA(5P20); arus termal jangka pendek berkisar 4–31,5kA, arus tahan dinamis nominal berkisar 10–130kA; berat produk: 84kg; suhu operasi lingkungan -5°C hingga +40°C.
Transformator Arus Resin Epoksi Cor Satu Fasa Dalam Ruangan, 10kV
Transformator arus resin epoksi cor satu fasa dalam ruangan sesuai standar GB/T20840.1/2 dan IEC61869-1/2. Tingkat isolasi: 12/42/75kV, frekuensi 50/60Hz, arus sekunder 5A atau 1A. Rentang arus primer opsional yang luas dari 20A hingga 6000A, berbagai kombinasi kelas akurasi untuk pengukuran dan proteksi, tap belitan sekunder yang dapat diubah (multi-rasio) tersedia untuk beberapa versi. Arus tahan termal waktu singkat dan arus tahan dinamis disesuaikan untuk setiap spesifikasi, cocok untuk pengukuran dan proteksi relai pada kabinet switchgear tegangan menengah. Suhu operasi lingkungan: -5°C hingga +40°C, tersedia berbagai pilihan dimensi dan berat untuk sub-versi yang berbeda.