中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLZZBJ9-35D1
LZZBJ9-35D1 Indoor Single-phase Epoxy Resin Casting Current Transformer
35kVLZZBJ9-35D1
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 35kV
Secondary Metering (1S1 - 1S2):5A/1A ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LZZBJ9-35D1

LZZBJ9-35D1 Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZBJ9-35D1 Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.

Key Engineering Advantages

  • 35kV indoor epoxy cast current transformer
  • high thermal/dynamic stability
  • multi-accuracy grades for selection
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LZZBJ9-35D1

Electrical Parameters

Primary Rated Voltage (Un):35kV
Secondary Winding Currents:5A/1A
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Insulation Level (BIL):40.5/95/185kV
Environmental Class:Ambient: -5℃~+40℃
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

35 kV four-core epoxy-cast CT, 20–3150 A, 0.2(S)/5P arrangements at 20–30 VA, 140 kg.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeLZZBJ9-35D1Factory nameplate marking
Primary Voltage35kVRated voltage test (IEC 61869-1/3)
Secondary Current5A/1ARatio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)40.5/95/185kVPower-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50/60HzPer IEC 61869-1
EnvironmentAmbient: -5℃~+40℃Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor medium-voltage switchgear panels
  • Revenue metering with 0.2S/0.5S accuracy
  • Protection schemes requiring 5P20/5P25/5P30
  • 10kV systems with high fault currents up to 150kA

Not Recommended For

  • Outdoor installations without additional enclosure
  • Gas-insulated switchgear (GIS) applications
  • DC systems or non-sinusoidal waveforms
  • High-altitude environments above 1000m

Topology & Wiring

connect primary through bushing; secondary terminals 1S1/1S2 for metering, 2S1-2S2 for protection. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point only. Follow IEC 61869-2 terminal markings.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: How many protection cores can the 35D1 carry?

A: Up to three, in the 0.2(S)/5P/5P/5P arrangement, alongside the metering core.

Q: What is the rated output of the metering core?

A: 30 VA, the highest metering output in the 35 kV LZZBJ9 range.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LZZBJ9-35D1
10 cols · 6 rows

LZZBJ9-35D1 Current Transformer

Rated primary current I1n (A)Accuracy classCombined0.2(S)/0.5(S)0.55P205P255P30Short-time thermal current Ith (kA/S)Rated dynamic current Idyn (kA)Weight (kg)
20-1000.2(S)/5P, 0.5(S)/5P, 0.2(S)/5P/5P, 0.2(S)/5P/5P/5P3030302520150 I1n375 I1n140
1500.2(S)/5P, 0.5(S)/5P, 0.2(S)/5P/5P, 0.2(S)/5P/5P/5P30303025202563140
200-2500.2(S)/5P, 0.5(S)/5P, 0.2(S)/5P/5P, 0.2(S)/5P/5P/5P303030252031.580140
300-5000.2(S)/5P, 0.5(S)/5P, 0.2(S)/5P/5P, 0.2(S)/5P/5P/5P303030252031.580140
600-8000.2(S)/5P, 0.5(S)/5P, 0.2(S)/5P/5P, 0.2(S)/5P/5P/5P303030252031.580140
1000-31500.2(S)/5P, 0.5(S)/5P, 0.2(S)/5P/5P, 0.2(S)/5P/5P/5P303030252031.580140
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LZZBJ9-35D1 — click image to zoom / view original.

Product Overview

About This Product

LZZBJ9-35D1

LZZBJ9-35D1 is the heaviest and most capable 35 kV frame in the family: 140 kg, 20 A to 3150 A, and metering cores rated 30 VA. The D1 casting carries four selectable core arrangements, from a single metering-plus-protection pair up to three protection cores alongside the metering core.

Its accuracy string is 0.2(S)/5P, 0.5(S)/5P, 0.2(S)/5P/5P or 0.2(S)/5P/5P/5P, with 30 VA on the metering core and 20–30 VA on the protection cores. Short-time thermal current is 150 times primary for 1 s at 20–100 A, then 25 kA, 31.5 kA and 31.5 kA with 63–80 kA dynamic ratings up to 3150 A.

Choose the D1 when a 35 kV feeder needs three independent protection zones plus revenue metering in one window, or when the connected burden exceeds the 10 VA of the lighter frames. The mass means it is normally lifted into place rather than hand-mounted, and the larger window requires the panel drawing to be checked before ordering.

Other Models in This Series

Same product family, different ratings — compare before you specify.

LZZBJ9-35G Indoor Single-phase Epoxy Resin Casting Current Transformer
35kV
Current Transformer50/60Hz

LZZBJ9-35-G

Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZBJ9-35G Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-35-G) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
LZZBJ9-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer
35kV
Current Transformer50/60Hz

LZZBJ9-35-Q

Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZBJ9-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-35-Q) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
LZZBJ9-10 Indoor Single-phase Epoxy Resin Casting Current Transformer,10kV
10kV
Current Transformer50/60Hz

LZZBJ9-10

Indoor Single-phase Epoxy Resin Casting Current Transformer,10kV

LZZBJ9-10 Indoor Single-phase Epoxy Resin Casting Current Transformer,10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.

Accuracy Class0.2/0.5/1.0/5P10/10P10/10P15
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs