LZZBJ9-35D1 Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.
35 kV four-core epoxy-cast CT, 20–3150 A, 0.2(S)/5P arrangements at 20–30 VA, 140 kg.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LZZBJ9-35D1 | Factory nameplate marking |
| Primary Voltage | 35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A/1A | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | 40.5/95/185kV | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Ambient: -5℃~+40℃ | Per datasheet limits |
Ideal For
Not Recommended For
connect primary through bushing; secondary terminals 1S1/1S2 for metering, 2S1-2S2 for protection. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point only. Follow IEC 61869-2 terminal markings.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: How many protection cores can the 35D1 carry?
A: Up to three, in the 0.2(S)/5P/5P/5P arrangement, alongside the metering core.
Q: What is the rated output of the metering core?
A: 30 VA, the highest metering output in the 35 kV LZZBJ9 range.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current I1n (A) | Accuracy classCombined | 0.2(S)/0.5(S) | 0.5 | 5P20 | 5P25 | 5P30 | Short-time thermal current Ith (kA/S) | Rated dynamic current Idyn (kA) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|
| 20-100 | 0.2(S)/5P, 0.5(S)/5P, 0.2(S)/5P/5P, 0.2(S)/5P/5P/5P | 30 | 30 | 30 | 25 | 20 | 150 I1n | 375 I1n | 140 |
| 150 | 0.2(S)/5P, 0.5(S)/5P, 0.2(S)/5P/5P, 0.2(S)/5P/5P/5P | 30 | 30 | 30 | 25 | 20 | 25 | 63 | 140 |
| 200-250 | 0.2(S)/5P, 0.5(S)/5P, 0.2(S)/5P/5P, 0.2(S)/5P/5P/5P | 30 | 30 | 30 | 25 | 20 | 31.5 | 80 | 140 |
| 300-500 | 0.2(S)/5P, 0.5(S)/5P, 0.2(S)/5P/5P, 0.2(S)/5P/5P/5P | 30 | 30 | 30 | 25 | 20 | 31.5 | 80 | 140 |
| 600-800 | 0.2(S)/5P, 0.5(S)/5P, 0.2(S)/5P/5P, 0.2(S)/5P/5P/5P | 30 | 30 | 30 | 25 | 20 | 31.5 | 80 | 140 |
| 1000-3150 | 0.2(S)/5P, 0.5(S)/5P, 0.2(S)/5P/5P, 0.2(S)/5P/5P/5P | 30 | 30 | 30 | 25 | 20 | 31.5 | 80 | 140 |
Dimension & outline drawing of LZZBJ9-35D1 — click image to zoom / view original.
LZZBJ9-35D1 is the heaviest and most capable 35 kV frame in the family: 140 kg, 20 A to 3150 A, and metering cores rated 30 VA. The D1 casting carries four selectable core arrangements, from a single metering-plus-protection pair up to three protection cores alongside the metering core.
Its accuracy string is 0.2(S)/5P, 0.5(S)/5P, 0.2(S)/5P/5P or 0.2(S)/5P/5P/5P, with 30 VA on the metering core and 20–30 VA on the protection cores. Short-time thermal current is 150 times primary for 1 s at 20–100 A, then 25 kA, 31.5 kA and 31.5 kA with 63–80 kA dynamic ratings up to 3150 A.
Choose the D1 when a 35 kV feeder needs three independent protection zones plus revenue metering in one window, or when the connected burden exceeds the 10 VA of the lighter frames. The mass means it is normally lifted into place rather than hand-mounted, and the larger window requires the panel drawing to be checked before ordering.
Same product family, different ratings — compare before you specify.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZBJ9-35G Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-35-G) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LZZBJ9-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-35-Q) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Epoxy Resin Casting Current Transformer,10kV
LZZBJ9-10 Indoor Single-phase Epoxy Resin Casting Current Transformer,10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.