KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLZZBJ9-35-G
LZZBJ9-35G Indoor Single-phase Epoxy Resin Casting Current Transformer
35kVLZZBJ9-35-G
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 35kV
Secondary Metering (1S1 - 1S2):5A/1A ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LZZBJ9-35-G

LZZBJ9-35G Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZBJ9-35G Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-35-G) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.

Key Engineering Advantages

  • 35kV indoor epoxy cast current transformer
  • stable insulation performance and rich configuration options
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LZZBJ9-35-G

Electrical Parameters

Primary Rated Voltage (Un):35kV
Secondary Winding Currents:5A/1A
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Insulation Level (BIL):40.5/95/185kV
Environmental Class:Ambient: -5℃~+40℃
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

35 kV epoxy-cast CT, 20–3150 A, six accuracy pairings at 10 VA per core, 78 kg.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeLZZBJ9-35-GFactory nameplate marking
Primary Voltage35kVRated voltage test (IEC 61869-1/3)
Secondary Current5A/1ARatio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)40.5/95/185kVPower-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50/60HzPer IEC 61869-1
EnvironmentAmbient: -5℃~+40℃Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor MV switchgear panels
  • Revenue metering (0.2S/0.5S accuracy)
  • Protection (5P/10P accuracy)
  • Current measurement up to 3150A

Not Recommended For

  • Outdoor installations
  • Gas-insulated switchgear (GIS)
  • DC systems
  • High-voltage transmission (above 35kV)

Topology & Wiring

secondary terminals 1S1/1S2 (protection winding 2S1-2S2). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: How does the 35G differ from the 35A?

A: The G frame offers 0.5(S) metering and additional core pairings; the A frame is 8 kg lighter with fewer combinations.

Q: What is the short-time rating at 800–1600 A?

A: 31.5 kA for 4 s, with a 130 kA dynamic rating.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LZZBJ9-35-G
12 cols · 9 rows

LZZB8-35G LZZBJ9-35G Current Transformer

Rated primary current I1n (A)Accuracy classCombinedAccuracy class & rated output (VA) COSΦ=0.8Accuracy class & rated output (VA) COSΦ=0.8Accuracy class & rated output (VA) COSΦ=0.8Accuracy class & rated output (VA) COSΦ=0.8Accuracy class & rated output (VA) COSΦ=0.8Accuracy class & rated output (VA) COSΦ=0.8Short-time thermal current Ith (kA/S)Short-time thermal current Ith (kA/S)Rated dynamic current Idyn (kA)Weight (kg)
200.2(S)/0.5(S)0.2(S)/0.5S0.2(S)/5P0.2(S)/0.5(S)/5P0.2(S)/5P/5P0.5(S)/5P/5P10411078
30-400.2(S)/0.5(S)0.2(S)/0.5S0.2(S)/5P0.2(S)/0.5(S)/5P0.2(S)/5P/5P0.5(S)/5P/5P10421078
500.2(S)/0.5(S)0.2(S)/0.5S0.2(S)/5P0.2(S)/0.5(S)/5P0.2(S)/5P/5P0.5(S)/5P/5P101213078
750.2(S)/0.5(S)0.2(S)/0.5S0.2(S)/5P0.2(S)/0.5(S)/5P0.2(S)/5P/5P0.5(S)/5P/5P101614078
100-1500.2(S)/0.5(S)0.2(S)/0.5S0.2(S)/5P0.2(S)/0.5(S)/5P0.2(S)/5P/5P0.5(S)/5P/5P102516378
200-3000.2(S)/0.5(S)0.2(S)/0.5S0.2(S)/5P0.2(S)/0.5(S)/5P0.2(S)/5P/5P0.5(S)/5P/5P1031.518078
400-6000.2(S)/0.5(S)0.2(S)/0.5S0.2(S)/5P0.2(S)/0.5(S)/5P0.2(S)/5P/5P0.5(S)/5P/5P1031.528078
800-16000.2(S)/0.5(S)0.2(S)/0.5S0.2(S)/5P0.2(S)/0.5(S)/5P0.2(S)/5P/5P0.5(S)/5P/5P1031.5413078
2000-31500.2(S)/0.5(S)0.2(S)/0.5S0.2(S)/5P0.2(S)/0.5(S)/5P0.2(S)/5P/5P0.5(S)/5P/5P10[On Request][On Request][On Request]78
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LZZBJ9-35-G — click image to zoom / view original.

Product Overview

About This Product

LZZBJ9-35-G

LZZBJ9-35G is the 35 kV model that balances mass and output: 78 kg, 20 A to 3150 A, and six accuracy pairings across its cores. It sits between the 70 kg 35A and the 140 kg 35D1, and is the usual choice for standard 35 kV indoor switchgear.

The datasheet gives 0.2(S)/0.5(S), 0.2(S)/0.5S, 0.2(S)/5P, 0.2(S)/0.5(S)/5P, 0.2(S)/5P/5P and 0.5(S)/5P/5P as selectable combinations, with 10 VA on each core. Short-time thermal current runs from 4 kA/1 s at 20 A to 31.5 kA/4 s at 800–1600 A, with dynamic ratings of 10–130 kA.

Compared with the 35A, the G frame adds the 0.5(S) metering class and slightly heavier output options; compared with the 35D1, it trades 30 VA protection cores for a 62 kg lighter casting. Specify the core pairing explicitly, since the same model code is delivered with several.

Other Models in This Series

Same product family, different ratings — compare before you specify.

LZZBJ9-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer
35kV
Current Transformer50/60Hz

LZZBJ9-35-Q

Indoor Single-phase Epoxy Resin Casting Current Transformer

LZZBJ9-35(Q) Indoor Single-phase Epoxy Resin Casting Current Transformer (LZZBJ9-35-Q) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A/1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
LZZBJ9-10 Indoor Single-phase Epoxy Resin Casting Current Transformer,10kV
10kV
Current Transformer50/60Hz

LZZBJ9-10

Indoor Single-phase Epoxy Resin Casting Current Transformer,10kV

LZZBJ9-10 Indoor Single-phase Epoxy Resin Casting Current Transformer,10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.

Accuracy Class0.2/0.5/1.0/5P10/10P10/10P15
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
LZZBJ9-10GWA,B,C 10kV Indoor Epoxy Cast Current Transformer for KYN28 Cabinet
10kV
Current Transformer50/60Hz

LZZBJ9-10GWA-B-C

10kV Indoor Epoxy Cast Current Transformer for KYN28 Cabinet

LZZBJ9-10GWA,B,C 10kV Indoor Epoxy Cast Current Transformer for KYN28 Cabinet (LZZBJ9-10GWA-B-C) is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A or 1A, accuracy class 0.2S, 0.5, 5P20, 5P30. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869, GB/T 20840.

Accuracy Class0.2S, 0.5, 5P20, 5P30
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869
View Specs